Installation Manual

Specifications
Type 1-Channel Wired RF Transmitter
Wiring
Switch Two 6" wires for N.O.
Power Two 6" wires for power input
Power
Battery 3VDC battery (CR-2032, included)
External
3~13 VDC output regulated
RF Frequency 315MHz*
Number of buttons 1
Channels 1
Possible codes Over 68 billion (6.8x10
10
)
Dimensions 1
1
/
4
"x2
3
/
16
"x
5
/
16
" (31.5x55x8 mm)
Dimensions
Wired Single-Channel
RF Transmitter
SK-919T1-GBWQ*
Installation Manual
*
433.92
MHz
version also available
SK
939T1
GB
W
Q
Actual range will vary greatly depending on the installation and operating environment
2
3
16
"
(55mm)
5
/
16
"
(8mm)
1
1
4
"
(31.5mm)
Electromagnetic lock
Make
any push
-
to
-
exit plate wireless
PUSH
TO
EXIT
Receiver
Wall
PIR
SL-126Q
Strobe
Convert photobeam sensors with dry contacts
into an entry alert
Transmitter
Receiver
Transmitter
Wireless equipment / perimeter security
Transmitter
Receiver
Transmitter
Receiver
Wireless doorbell / service call button
PIR
Wall
Strobe
Powered by internal battery or external 3~13
VDC output regulated adapter (not included)
Frequency 315MHz*
Operates up to 500ft (150m)
Over 68 billion (6.8x10
10
) possible codes
LED transmission indicator
Includes one 3VDC lithium battery
(CR-2032)
Compact size
Compatible with all SECO-LARM SK-series
receivers of the same frequency
Also available without logo –
SK-919T1-GBWUQ – 315MHz
SK-939T1-GBWUQ – 433.92MHz
Sample Applications
ENFORCER
ENFORCERENFORCER
ENFORCER Wired Single-Channel RF Transmitter
Installation
Power Connection
The wired transmitter can be powered by the factory preinstalled 3VDC lithium battery (CR-2032) or by
a
n external 3~13VDC output regulated adapter (not included).
If an external power adapter is preferred, connect the red and black wires of the wired transmitter to the
adapter's output wires, being careful to ensure correct polarity. The red wire is connected to the positive
and the black wire to the negative.
NOTES:
T
he power input range of the wired transmitter is 3~13VDC and is polarity sensitive. Connecting
more than 13VDC or reversing the polarity will burn out the unit and void the warranty.
Use only "regulated" adapters to power the wired transmitter.
If using an external power adapter, the factory-installed lithium CR-2032 battery will serve as a
backup in case of power interruption (Battery must be removed for external inline power-on switch).
If connected to an external power-on switch, it is suggested that you remove the battery to disable
the built-in button so that it can only be controlled by the power-on switch.
External Switch Connection
The wired transmitter can be controlled by its built-in button (see Fig. 1), by an external N.O. switch* only
(button, contact, or sensor, see Fig. 2), or by both (Fig. 3). To disable the built-in button, the external
switch must be installed inline to the positive terminal of the power source with the battery removed.
NOTES:
Any wires not in use must be insulated to avoid a short-circuit
Do not let the red wire touch any other wire. Doing so may burn out the transmitter.
*Switch not included
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800
Email:
sales@seco
-
larm.com
PITSW1
Order Part#
762
-
121
%
MI_SK
-
9x9T1
-
GBWQ_210114
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale
to the original
customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-
LARM. This Warranty is void
if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or fau
lty installation, or if for any
other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workma
nship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-
LARM be liable for any
special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-
LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2021 SECO-LARM U.S.A.,
Inc.
All rights reserved.
California Proposition 65 Warning: These products may contain chemicals which are known to the State of California
to cause cancer and birth defects or other reproductive harm.
For more information, go to www.P65Warnings.ca.gov.
Fig. 1
Built
-
in button
+
Red
Black
Blue wires
Insulate unused wires
AC Adapter optional
3~13 VDC
DC Soure
Fig. 3
External switch and
built-in button
+
Red
Black
Blue wires
AC
Adapter optiona
l
. If not used,
insulate red and black wires.
3~13 VDC
Switch
Fig. 2
External
inline
power-on switch
+
Red
Black
Blue wires
Connect the blue wires
.
The
battery
must be removed in this situation.
3~13 VDC
Switch
FCC COMPLIANCE STATEMENT FCC ID: K4E919T2GDW
This device complies with part 15 of the FCC rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2)
this device must
accept any interference received, including interference that may cause undesired operation.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the de
vice
could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.
DC Soure
DC Soure

Summary of content (1 pages)