Pub No.
MODEL 13800 User Guide ENERNET CORPORATION IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. THIS EQUIPMENT COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
MODEL 13800 User Guide ANTENNA FCC ID: TGD13800 / IC: 6120A-13800 The wireless RF equipment described in this document is supplied This device complies with Part 15 of the FCC Rules. Operation is with one of the following two (2) antenna configurations.
MODEL 13800 User Guide INTRODUCTION MESH NETWORK OVERVIEW This document discusses the model 138 Programmable Serial A simple overview example of EnernetWorks™ is shown in Gateway — EnernetWorks™ Network Adapter (PSG). The Figure 1. A network interface device communicates with an arbitrary number of targeted EnernetWorks™ capable nodes PSG Network Adapter provides a bridge between an EnernetWorks™ 900MHz mesh network and an EIA-232 network interface device.
MODEL 13800 User Guide Network Interface Thermostat Control Node Model 138 1st Gateway RS232 Thermostat Control Node Thermostat Control Node Thermostat Control Node Thermostat Control Node N Ø Building Electrical wiring RF/PLC Repeater Thermostat Control Node Model 138 2nd Gateway RF/PLC Repeater Thermostat Control Node Thermostat Control Node Thermostat Control Node RF/PLC Repeater Thermostat Control Node Thermostat Control Node Figure 1: EnernetWorks™ Mesh Network Overview 5 Thermost
MODEL 13800 User Guide INTERCONNECTION The PSG Network Adapter is powered by the supplied 9-volt DC wall-plug power source. A standard 9-pin serial cable connects Decimal S1 S2 S3 S4 S5 S6 S7 S8 the PSG Network Adapter to a network interface device. (Refer to 0 DN DN DN DN DN DN DN DN Figure 2.) 1 DN DN DN DN DN DN DN UP 2 DN DN DN DN DN DN UP DN 3 DN DN DN DN DN DN UP UP etc.
MODEL 13800 User Guide ANTENNA P/N: ANT-916-CW-RH ANT CONNECTOR NETWORK ADAPTER EIA-232 SERVICE 9-Pin Serial cable CONFIGURATION POWER NETWORK Wall-Plug Figure 2: Network Adapter — Programmable Serial Gateway 7
MODEL 13800 User Guide SERVICE 1 BUTTON NETWORK CONFIGURATION 2 3 4 5 6 7 8 LED Figure 3: Network Adapter — Configuration Switches and Service Pin Button NOTE: The orange two-pin connector labeled “NETWORK” is not used.
MODEL 13800 User Guide TESTING 6. You can now execute the following PSG Network Adapter commands as needed: The PSG Network Adapter operates in two protocol modes – binary and ASCII. Binary mode is used only by applications such CMD as the Monet™ suite, and enables detailed, automated control and ? Display firmware version number B or b Set building address. Same as setting DIP switches. S or s Toggle serial diagnostic mode. Certain mesh network monitoring of target nodes on the mesh network.
MODEL 13800 User Guide N or n X or x Invoke and display PSG Network Adapter neighbor 3. If you are using the dipole/cable antenna option, place count (see next section) only the antenna in its proposed location. Screw the Enable/disable ASCII responses. Used to squelch any other end of the cable to the PSG Network Adapter ASCII asynchronous responses (i.e. send only binary antenna connector. (WARNING: HAND TIGHTEN mode). This is reset by command R ONLY, DO NOT USE TOOLS.