TI01253G/00/EN/02.16 Products Solutions Services Technical Information Micropilot NMR84 Tank Gauging Application Micropilot NMR8 Series intelligent tank gauges are designed for high accuracy liquid level measurement in storage and process applications. They fulfill the exacting demands of tank inventory management, inventory control, custody transfer, loss control, total cost saving, and safe operation.
Micropilot NMR84 Table of contents Document information . . . . . . . . . . . . . . . . . . . . . . . 3 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Function and system design . . . . . . . . . . . . . . . . . . . 5 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Integration of tank sensors . . . . . . . . . . . . . . . . . . . . . . . 6 Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Input . . . . . . . . .
Micropilot NMR84 Document information Symbols Safety symbols Symbol Meaning DANGER DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION CAUTION! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury.
Micropilot NMR84 Symbols in graphics Symbol Meaning 1, 2, 3 ... Item numbers , , … A, B, C, ... A-A, B-B, C-C, ... 4 Series of steps Views Sections - Hazardous area Indicates a hazardous area. . Safe area (non-hazardous area) Indicates the non-hazardous area.
Micropilot NMR84 Function and system design Measuring principle Micropilot is a directional level radar, operating based on the "Frequency-Modulated Continuous Wave" principle (FMCW). The radar emits a precise crystal-oscillated, continuously varying frequency wave from the antenna. The wave is reflected off the product surface and received again by the radar system. D R A0023768 1 R D FMCW principle: Emission and reflection of the continuous wave.
Micropilot NMR84 Integration of tank sensors In addition to measuring the level, the device can also be used for the integration of tank sensors into tank inventory systems. All measured and calculated values can be displayed at the built-in display. Via a field communication protocol, they can be transferred to an inventory control system.
Micropilot NMR84 Measuring system • From single tank level measurement to the largest oil refinery applications, Endress+Hauser tank gauging devices are an integral part of tank farm management solutions. A wide variety of data output protocols are available for seamless integration into many commonly used systems. • A primary example is Tankvision from Endress+Hauser. Tankvision is a scalable system offering local tank management for multiple loops via Modbus or V1 protocols.
Micropilot NMR84 Input Measured variable Maximum measuring range The measured variable is the distance between a reference point (mounting flange) and a reflective surface (e.g. product surface). Antenna 1) Weight+Measure approval 2) Maximum measuring range BD: Planar 100mm/4" any 0.8 to 20 m (2.
Micropilot NMR84 Output I/O modules D 1 2 3 4 C 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 A 1 2 3 4 D 1 2 3 4 C 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 A 1 2 3 4 1 2 E 1 2 E 1 CDI 3 4 1 CDI i F 21 1 G2 HR on 3 POWER WP SIM i F 12 G12 3 4 HR on POWER WP SIM A0027363 6 Position of the I/O modules in the terminal compartment The terminal compartment contains up to four I/O modules, depending on the order code. • Modules with four terminals can be in any of these slots.
Micropilot NMR84 Ordering feature 060: "Secondary IO Digital Exd" NMx8x - xxxx xx xx XX ...
Micropilot NMR84 "V1": Technical data No.
Micropilot NMR84 Power supply Terminal assignment D 1 2 3 4 C 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 A 1 2 3 4 1 D 1 2 3 4 C 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 A 1 2 3 4 1 2 E 1 2 E CDI i F 12 3 4 HR on 3 POWER WP SIM 1 CDI 1 G2 i F 12 3 4 1 G2 HR on 3 WP SIM POWER G1 L G3 N AC 85...
Micropilot NMR84 Cable entries Ordering feature 090 "Electrical Connection" 1) Cable entries (with blind plugs) A 7 x thread M20 B 7 x thread M25 C 7 x thread G1/2 D 7 x thread G3/4 E 7 x thread NPT1/2 F 7 x thread NPT3/4 1) Position 13 of the order code, e.g. NMx8x-xxxxxxxxxxxxA... For the following devices with TIIS Ex d approval, cable glands are attached to the device (see position 1 and 2 of the order code). These cable glands must be used. • Micropilot NMR84-TA...
Micropilot NMR84 Performance characteristics Reference operating conditions According to OIML R85 (2008) • Temperature: –25 to +55 °C (–13 to 131 °F) • Atmospheric pressure • Relative humidity (air): 65 % ±15 % • Medium with good reflectivity and calm surface • No major interference reflections inside the signal beam Measured value resolution ≤ 0.1 mm (0.
Micropilot NMR84 Installation Installation conditions Conditions for the stilling well • • • • • • • • • Metal (no enamel coating) Constant diameter (no rectangular stilling wells) Weld seam as smooth as possible For best radar propagation behavior it is recommended to have holes instead of slots. If slots can not be avoided, they should be as thin and short as possible. Maximum gap between antenna/horn and wall of the stilling well: 5 mm (0.2 in). At any transition (e.g.
Micropilot NMR84 Environment Ambient temperature range Device –40 to +60 °C (–40 to +140 °F) Display module –20 to +70 °C (–4 to +158 °F) readability of the display may be impaired at temperatures outside this temperature The range. The following diagrams take into account only functional aspects. There may be further restrictions for certified device versions. Please refer to the separate Safety Instructions.
Micropilot NMR84 With a temperature (Tp) at the process connection the admissible ambient temperature (Ta) is reduced according to the following diagram (temperature derating): Ambient temperature limits for NMR81 P1 Ta P2 P3 Tp P4 P5 Temperature unit: °C (°F) I/O configuration A0019351 P1 P2 P3 P4 P5 Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta 1 -40 (-40) 55 (131) 55 (131) 55 (131) 150 (302) 50 (122) 150 (302) -40 (-40) -40 (-40) -40 (-40) 2 -40 (-40) 60 (140) 60 (140) 60 (140) 150 (
Micropilot NMR84 Process Process temperature range Process pressure range Dielectric constant 18 Device Process temperature range NMR84 –40 to +150 °C (–40 to +302 °F) Device Process pressure range NMR84 –1 to +25 bar (–14.5 to +362 psi) Application Dielectric constant Stilling well εr ≥ 1.
Micropilot NMR84 Custody transfer approval Ordering feature 150 "Accuracy, Weight + Measure Approval" 1) Accuracy properties ICR Standard version (±1 mm), without calibration certificate ICW Standard version (±1 mm), 3-point calibration certificate ICX Standard version (±1 mm), 5-point calibration certificate NTA (in preparation) Maximum performance (±0.5 mm), type approval according to NMi, OIML R85, API 3.
Micropilot NMR84 Mechanical construction Dimensions Housing 144 (5.67) ø20 1 (7 .91 ) 215 (8.46) A0023482 9 Dimensions of the electronics housing; unit of measurement: mm (in); adapters for cable entries are not taken into account in this drawing. Process connection and sensor B b b A 28.8(1.13) 46.5(1.83) 96.5(3.8) 117.5 (4.63) ø150(5.91) L1 ø100(3.94) øE 30.5(1.2) 37.9(1.49) 68.5(2.7) 117.5 (4.
Micropilot NMR84 Antenna extension Ordering feature 100 "Antenna" 1) Dimension BD: Planar 100mm/4" BF: Planar 150mm/6" BG: Planar 200mm/8" e - - 192 mm (7.56 in) 242 mm (9.53 in) 292 mm (11.5 in) L1 - - 341 mm (13.4 in) 494 mm (19.4 in) 521 mm (20.5 in) 1) BH: Planar 250mm/10" BJ: Planar 300mm/12" Position 14 and 15 of the order code Flanges according to ASME B16.5 Pressure rating 1) 150 lbs 300 lbs 1) Nominal diameter 1) Dimension 4" 6" 8" 10" b 23.9 mm (0.94 in) 25.
Micropilot NMR84 Flanges according to JPI 7S-15 Pressure Dimension ratingNomina l diameter 1) 150 lbs 300 lbs 1) 22 Nominal diameter 1) 100A 150A b 23.9 mm (0.94 in) 25.4 mm (1 in) E 228.6 mm (9 in) 279.4 mm (11 in) b 31.8 mm (1.
Micropilot NMR84 UNI flanges ø23 (0.91) ø12 (0.47) B A-A 3 1 8 (0.31) M80x1.5 2 A A øK øD D C 15° 60 ° ø29 (1.14) 60 ° 90° ø26 (1.02) øK øD øK øD A0027691 11 B C D UNI flange DN150/6"/150 UNI flange DN200/8"/200 UNI flange DN250/10"/250 Position Option of ordering feature 140 ("Process Connection") 1) Suitable for B RKJ C D 1) Endress+Hauser UNI flanges ⌀D ⌀K Material • DN150, PN10/16 (EN1092-1) 280 mm • NPS 6" Cl. 150 (ASME B16.5) (11.
Micropilot NMR84 2 [0°] 1 [337.5°] 0° 4 [22.5°] 2 [60°] 3 [322.5°] 1 [67.5°] 2 [300°] 3 [82.5°] 1 [292.5°] 1 [112.5°] 3 [262.5°] 2 [120°] 1 [247.5°] 3 [142.5°] 2 [240°] 1 [157.5°] 4 [202.5°] 2 [180°] ø482 (19) ±1.5 A0027690 12 1 2 3 4 24 Bores for 10K 300A (JIS B2220) Bores for NPS 12" Cl.150 (ASME B16.
Micropilot NMR84 Materials Materials of housing 1 8 2 7 9 3 10 6 4 5 A0027788 Endress+Hauser Pos. Part Materials for Aluminum version 1) Materials for stainless steel version 2) 1 Housing AC 43000 T6 316L (1.4404) 2 Cover • • • • • • • • 3 Cover lock • Capstan screw: 316L (1.4404) • Clamp: 316L (1.4435) • Capstan screw: 316L (1.4404) • Clamp: 316L (1.4435) 4 Tag for measuring point label 316L (1.4404) 316L (1.4404) 5 Pressure release stopper for Ex i/IS chamber 316L (1.
Micropilot NMR84 Pos. Part Materials for Aluminum version 1) Materials for stainless steel version 2) 9 Dummy plug, cable gland or adapter 3) • Dummy plug – 1.4435 – LD-PE • Adapter: – Ms/Ni (TIIS) – 1.4404 (other versions) • Seal: – EPDM – NBR – PTFE tape • Dummy plug – 1.4435 – LD-PE • Adapter: – Ms/Ni (TIIS) – 1.4404 (other versions) • Seal: – EPDM – NBR – PTFE tape 10 Ground terminal • Screw: A4-70 • Spring washer: A4 • Clamp and holder: 316L (1.
Micropilot NMR84 Materials of antenna and process connection A B 1 1 2 2 3 A0018957 A B Pos. Part Material 1 Flange ASME/EN/JIS/JPI: 316L (1.4404/1.4435) Adapter 316L (1.4404) Housing adpater 316L (1.4404) Sensor adapter 316L (1.4404) Housing and retaining ring 316L (1.4404) Screw A2 Planar antenna PTFE Sealing ring FKM /HNBR / FFKM Antenna extension 316L (1.
Micropilot NMR84 Operability Operating concept Operator-oriented menu structure for user-specific tasks • Commissioning • Operation • Diagnostics • Expert level Operating languages • English • German • Japanese Feature 500 of the product structure determines which of these languages is preset on delivery.
Micropilot NMR84 Remote operation 7 5 6 NXA820 4 1 2 3 A0025621 14 1 2 3 4 5 6 7 Remote operation of Tank Gauging devices Proservo NMS8x Tankside Monitor NRF81 Micropilot NMR8x Field protocol (e.g. Modbus, V1) Tankvision Tank Scanner NXA820 Ethernet Computer with operating tool (e.g.
Micropilot NMR84 Certificates and approvals CE mark The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the corresponding EC Declaration of Conformity together with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
Micropilot NMR84 produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. [Any] changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Micropilot NMR84 Metrological standards • OIML R85 (2008) "Requirements for ambient temperature low –25 °C (–13 °F) and ambient temperature high +55 °C (+131 °F) • "Mess- und Eichverordnung" (Calibration regulations for the Federal Republic of Germany) • Directive 2004/22/EC of the European Parliament and of the Council of 31 March 2004 on measuring instruments 32 Endress+Hauser
Micropilot NMR84 Ordering information Ordering information Detailed ordering information is available from the following sources: • In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate" -> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator. • From your Endress+Hauser Sales Center: www.addresses.endress.
Micropilot NMR84 Customized parametrization Option of ordering feature 570 "Service" Meaning IJ Customized parametrization HART (in preparation) IX Customized parametrization V1 (in preparation) IZ Customized parametrization Modbus (in preparation) If one of these options has been selected, customer specific presets can be selected for the following parameters: Marking Parameter Selection list / range of values Tank reference height 0 to 999 999.
Micropilot NMR84 Application packages Advanced tank measurement methods The device software provides the following tank measurement methods: • Direct level measurement → 35 • Hybrid tank measurement system (HTMS) → 36 • Hydrostatic tank shell correction (HyTD) → 37 • Thermal tank shell correction (CTSh) → 37 Direct level measurement If no advanced tank measurement methods have been selected, level and temperature are measured directly.
Micropilot NMR84 Hybrid tank measurement system (HTMS) HTMS uses level and pressure measurements to calculate the contents of the tank and (optionally) the density of the medium. HTMS measuring modes Measuring mode Installation example HTMS + P1 Measured variables Calculated variables Density of the • Level • Bottom pressure (at position medium D1) 1 mode should be used in atmospheric (i.e.
Micropilot NMR84 Hydrostatic tank shell correction (HyTD) Δx The hydrostatic tank shell correction can be used to compensate for vertical movement of the Gauge Reference Height due to bulging of the tank shell caused by the hydrostatic pressure exerted by the liquid stored in the tank. The compensation is based on a linear approximation obtained from manual hand dips at several levels distributed over the full range of the tank.
Micropilot NMR84 Accessories Device-specific accessories Weather protection cover 56.1 (2.21) 32.5 (1.28) 319 (12.6) 361.6 (14.2) A0028019 17 Weather protection cover; dimensions: mm (in) Materials Part Material Protection cover and mounting brackets 316L (1.4404) Screws and washers A4 The weather protection cover can be ordered together with the device (ordering feature 620 "Accessory Enclosed", option PA "Weather Protection Cover") or as an accessory.
Micropilot NMR84 Communication-specific accessories Accessory Description Commubox FXA195 HART For intrinsically safe HART communication with FieldCare via the USB interface. Accessory Description Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a computer.
Micropilot NMR84 Documentation Technical Information (TI) Brief Operating Instructions (KA) The Technical Information contains all the technical data on the device and provides an overview of the accessories and other products that can be ordered for the device. Device Technical Information Micropilot NMR84 TI01253G The Brief Operating Instructions contain all the essential information from incoming acceptance to initial commissioning.
Micropilot NMR84 Registered trademarks FieldCare® Registered trademark of the Endress+Hauser Process Solutions AG, Reinach, Switzerland MODBUS® Registered trademark of the MODBUS-IDA, Hopkinton, MA, USA Endress+Hauser 41
*unbekannt* www.addresses.endress.