TI01304F/00/EN/03.17 Products Solutions Services Technical Information Micropilot FMR67 Free space radar Level measurement in bulk solids Application • Continuous, non-contact level measurement of bulk solids ranging from powdery to lumpy • PTFE drip-off antenna or PTFE-plated, flush-mounted antenna • Maximum measuring range: 125 m (410 ft) • Temperature: –40 to +200 °C (–40 to +392 °F) • Pressure: –1 to +16 bar (–14.5 to +232 psi) • Accuracy: ± 3 mm (0.
Micropilot FMR67 Table of contents Important document information . . . . . . . . . . . . . . . 4 Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols for certain types of information . . . . . . . . . . . . . . Symbols in graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols at the device . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 4 4 5 Storage temperature . . .
Micropilot FMR67 Application Packages . . . . . . . . . . . . . . . . . . . . . . . 68 Heartbeat Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . Heartbeat Verification . . . . . . . . . . . . . . . . . . . . . . . . . Heartbeat Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 68 69 70 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . Communication-specific accessories . . . . . .
Micropilot FMR67 Important document information Safety symbols Symbol Meaning DANGER DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION NOTE! This symbol contains information on procedures and other facts which do not result in personal injury.
Micropilot FMR67 Symbol Symbols at the device Meaning - Hazardous area Indicates a hazardous area. . Safe area (non-hazardous area) Indicates the non-hazardous area. Symbol Meaning Safety instructions Observe the safety instructions contained in the associated Operating Instructions. Temperature resistance of the connection cables Specifies the minimum value of the temperature resistance of the connection cables. Endress+Hauser V. 1, Rev.
Micropilot FMR67 Terms and abbreviations Term/abbreviation Explanation 6 BA Document type "Operating Instructions" KA Document type "Brief Operating Instructions" TI Document type "Technical Information" SD Document type "Special Documentation" XA Document type "Safety Instructions" PN Nominal pressure MWP Maximum Working Pressure The MWP can also be found on the nameplate.
Micropilot FMR67 Registered trademarks HART® Registered trademark of the HART Communication Foundation, Austin, USA KALREZ®, VITON® Registered trademark of DuPont Performance Elastomers L.L.C., Wilmington, USA TEFLON® Registered trademark of E.I. DuPont de Nemours & Co., Wilmington, USA Endress+Hauser V. 1, Rev.
Micropilot FMR67 Function and system design Measuring principle The Micropilot is a "downward-looking" measuring system, operating based on the frequency modulated continuous wave method (FMCW). The antenna emits an electromagnetic wave at a continuously varying frequency. This wave is reflected by the product and received again by the antenna.
Micropilot FMR67 Input Measured variable The measured variable is the distance between the reference point and the product surface. The level is calculated based on "E", the empty distance entered. Optionally, the level can be converted to other variables (volume, mass) by linearization (32 value pairs).
Micropilot FMR67 Output Output signal HART Signal coding FSK 0.5 mA over current signal Data transmission rate 1 200 Bit/s Galvanic isolation Yes Switch output For HART devices, the switch output is available as an option. See product structure, feature 20: "Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output" Devices with PROFIBUS PA and FOUNDATION Fieldbus always have a switch output.
Micropilot FMR67 Galvanic isolation All circuits for the outputs are galvanically isolated from each other. Protocol-specific data HART Manufacturer ID 17 (0x11) Device type ID 0x112B HART specification 7.0 Device description files (DTM, DD) Information and files under: • www.endress.com • www.fieldcommgroup.org HART load min. 250 Ω HART device variables The measured values can be freely assigned to the device variables.
Micropilot FMR67 Power supply Terminal assignment 2-wire: 4-20mA HART 9 8 ! 2- w 4-2 ire le 0 ve HA mA [21 RT ] A l 4-2 0m A ope n 5 1 6 - 2 mm 4 10 2 4... HA 20mA RT + 1 Sp a 711 re pa 08x rt xx + – + – # 4...20 mA 3 B 7 1 2 4 1-c 5 han [16 ] nel ove r + 1 4-2 2 volt 0m A age pro tec + – tion + – # 4...
Micropilot FMR67 2-wire: 4-20mA HART, switch output 10 9 8 % 2- w 4-2 ire 0 7 4+ – S ope n + 1 2 Sp a 711 re pa 08x rt xx m ++ 31 -42 3+ PF 10 m A 4... HA 20 mA RT HA mA [02 RT /03 ] 6 + ≥250 Ω 4...20 mA $ 1 2 3 5 4 B 3+ + 3 4-2 4 11 0m A/ 2-c 4[17 ] + – han nel + + 1 4-2 2 FIE 0mA ove rvo LD / ltag BU ep S rote ctio n $ 1 ≥250 Ω 4...
Micropilot FMR67 2-wire: 4-20mA HART, 4-20mA 14 13 12 # 2- w 4-2 ire le 0 ve 0m A n + – 1 " + 1 2 10 + mm 11 Sp a 711 re pa 08x rt xx 4... HA 20mA RT ope 4... + 3 4 l 4-2 A A 20m HA mA [04 RT /05 ] 4...20 mA 8 9 4 + – 2 " + 4...20 mA 5 6 3 7 4 B + – 1 " + + 3 4-2 4 4...20 mA 4 8 9 0m A/ 10 2-c han [17 ] nel + 1 - 2 4FIE 20mA ove rvo LD / ltag B U ep S ro tec + – 2 " + tion 4...
Micropilot FMR67 4-wire: 4-20mA HART (10.4 to 48 VDC) 13 12 11 ! 2- w 4-2 ire 0 + 3 4 10 9 Sp a 711 re pa 08x rt xx mm 10 L+ 1 L2 ope n 4... HA 20 mA RT 48 V= 10. 4... A HA mA [08 RT ] + 8 7 ! ≥250 Ω 4...20 mA 6 1 2 3 4 5 A0011340 6 1 2 3 4 5 6 7 8 9 10 11 12 13 Endress+Hauser Terminal assignment 4-wire; 4-20mA HART (10.4 to 48 VDC) Evaluation unit, e.g.
Micropilot FMR67 4-wire: 4-20mA HART (90 to 253 VAC) 13 12 11 ! Sp a 711 re pa 08x rt xx + 3 4 mm 9 n 8 10 10 L 1 N 2 ope 4... HA 20 mA RT 3V 90. ..25 A ~ 2- w 4-2 ire 0 HA mA [09 RT ] + 7 ! ≥250 Ω 4...20 mA 6 1 2 3 4 5 A0018965 7 1 2 3 4 5 6 7 8 9 10 11 12 13 Terminal assignment 4-wire; 4-20mA HART (90 to 253 VAC) Evaluation unit, e.g.
Micropilot FMR67 Connection examples for the switch output For HART devices, the switch output is available as an option. See product structure, feature 20: "Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output" Devices with PROFIBUS PA and FOUNDATION Fieldbus always have a switch output.
Micropilot FMR67 Device plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected without opening the housing. Pin assignment of the M12 plug connector 4 3 1 2 A0011175 Pin Meaning 1 Signal + 2 not connected 3 Signal - 4 Ground Pin Meaning 1 Signal - 2 Signal + 3 Not connected 4 Screen Pin assignment of the 7/8" plug connector 1 3 2 4 A0011176 18 V. 1, Rev.
Micropilot FMR67 Supply voltage An external power supply is necessary. Various power supply units can be ordered as an accessory from Endress+Hauser.
Micropilot FMR67 "Power supply, output" 1) "Approval" 2) Terminal voltage U at device Maximum load R, depending on the supply voltage U0 of the power supply unit C: 2-wire; 4-20mA HART, 4-20mA All R [W] 16 to 30 V 500 0 10 16 20 27 30 35 U0 [V] A0031746 1) 2) Feature 020 in the product structure Feature 010 in the product structure Integrated polarity reversal protection Yes Permitted residual ripple with f = 0 to 100 Hz USS < 1 V Permitted residual ripple with f = 100 to 10000 Hz USS
Micropilot FMR67 Cable entries Connection of power supply and signal line To be selected in feature 050 "Electrical connection" • Gland M20; Material dependent on the approval: – For Non-Ex, ATEX, IECEx, NEPSI Ex ia/ic: Plastics M20x1.5 for cable ⌀5 to 10 mm (0.2 to 0.39 in) – For Dust-Ex, FM IS, CSA IS, CSA GP, Ex nA: Metal M20x1.5 for cable ⌀7 to 10 mm (0.28 to 0.39 in) 1) – For Ex d: No gland available • Thread – ½" NPT – G ½" – M20 × 1.
Micropilot FMR67 External overvoltage protection HAW562 or HAW569 from Endress+Hauser are suited as external overvoltage protection. For detailed information please refer to the following documents: • HAW562: TI01012K • HAW569: TI01013K 22 V. 1, Rev.
Micropilot FMR67 Performance characteristics Reference operating conditions • • • • • Reference accuracy Typical data under reference operating conditions: DIN EN IEC 61298-2 / DIN EN IEC 60770-1; percentage values in relation to the span. Temperature = +24 °C (+75 °F) 5 °C (9 °F) Pressure = 960 mbar abs. (14 psia) 100 mbar (1.
Micropilot FMR67 Response time Influence of ambient temperature 2) 24 The response time can be configured. The following step response times (in accordance with DIN EN IEC 61298-2 / DIN EN IEC 60770-1) 2) are when damping is switched off: Sampling rate ≥1.3 s–1 at U ≥ 24 V Response time < 3.
Micropilot FMR67 Installation Installation conditions Mounting position 1 2 3 A A0016883 • Recommended distance A wall - nozzle outer edge: ~ 1/6 of the container diameter. However, the device must not under any circumstances be mounted closer than 20 cm (7.87 in) to the container wall. If the container wall is not smooth (corrugated iron, welding seams, joints, etc.) it is recommended to maintain the largest possible distance from the wall.
Micropilot FMR67 Internal container fittings β α A0031814 Avoid the location of internal fittings (limit switches, temperature sensors, struts etc.) inside the signal beam. Pay attention to the beam angle . 26 V. 1, Rev.
Micropilot FMR67 Avoiding interference echoes β α A0031817 Metal deflection plates installed at an angle to scatter the radar signals help prevent interference echoes. Optimization options • Antenna size The larger the antenna the smaller the beam angle α,resulting in fewer interference echoes . • Mapping Measurement can be optimized by electronically suppressing interference echoes.
Micropilot FMR67 Beam angle D α W= 2 . D . tan_ 2 α W A0031824 11 Relationship between beam angle α, distance D and beamwidth diameter W The beam angle is defined as the angle α where the energy density of the radar waves reaches half the value of the maximum energy density (3dB width). Microwaves are also emitted outside the signal beam and can be reflected off interfering installations. 28 V. 1, Rev.
Micropilot FMR67 FMR67 A0032084 A0032083 Antenna 1) Drip-off, PTFE 50 mm / 2" PTFE flush mount 80 mm / 3" Beam angle α 6° 4° Distance (D) 1) Installation: Drip-off antenna PTFE 50 mm / 2" Beamwidth diameter W 5 m (16 ft) 0.52 m (1.70 ft) 0.35 m (1.15 ft) 10 m (33 ft) 1.05 m (3.44 ft) 0.70 m (2.30 ft) 15 m (49 ft) 1.57 m (5.15 ft) 1.05 m (3.44 ft) 20 m (66 ft) 2.10 m (6.89 ft) 1.40 m (4.59 ft) 25 m (82 ft) 2.62 m (8.60 ft) 1.75 m (5.74 ft) 30 m (98 ft) 3.14 m (10.30 ft) 2.
Hmax Micropilot FMR67 øD A0032209 Inner nozzle diameterD Maximum nozzle height Hmax min. 50 mm (2 in) ≤150 mm (6 in) 80 mm (3 in) ≤200 mm (8 in) 100 mm (4 in) ≤300 mm (12 in) 150 mm (6 in) ≤500 mm (20 in) Note the following if the antenna does not project out of the nozzle: • The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be rounded if possible. • Mapping must be performed.
Micropilot FMR67 A0032097 12 Micropilot FMR67 with alignment unit Radial alignment of the antenna Radial alignment of the antenna is not necessary because the effect of polarization is negligible due to the narrow beam angle. Hmax Information concerning nozzles øD A0032206 Inner nozzle diameterD Maximum nozzle height Hmax min.
Micropilot FMR67 Purge air connection for FMR67 Purge air adapter for Drip-off antennas Purge air connection 1) Meaning A without 3 Purge air adapter G 1/4" 4 Purge air adapter NPT 1/4" 1) Feature 110 in the product structure 1 A0032098 1 Purge air connection NPT 1/4" or G 1/4" Integrated purge air connection for flush-mounted antennas Purge air connection 1) Meaning 1 Purge air connection G 1/4" 2 Purge air connection NPT 1/4" 1) Feature 110 in the product structure 1 1 A0032099
Micropilot FMR67 Use In applications with strong dust emissions, the integrated purge air connection can prevent the antenna from becoming clogged. Pulse operation is recommended. Purge air pressure range • Pulse operation : Max. 6 bar (87 psi) • Continuous operation: 200 to 500 mbar (3 to 7.25 psi) Always use dry purge air. In general, purging should only be performed to the extent necessary as excess purging can cause mechanical damage (abrasion).
Micropilot FMR67 Environment Ambient temperature range Measuring device –40 to +80 °C (–40 to +176 °F) Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at temperatures outside the temperature range. Outdoor operation in strong sunlight: • Mount the device in the shade. • Avoid direct sunlight, particularly in warm climatic regions. • Use a weather protection cover (see accessories). The following diagrams only consider functional aspects.
Micropilot FMR67 FMR67 Ta P1 Antenna 1) GP: PTFE flush mount DN80 P2 P3 Seal 2) A6: FKM Viton GLT, –40 to 200 °C (–40 to 392 °F) Tp P5 P4 Temperature specifications: °C (°F) Housing type 3) A0032024 P1 Tp P2 Ta Tp P3 Ta P4 Tp Ta Tp P5 Ta Tp Ta –40 (–40) –40 (–40) –40 (–40) B: GT18 two-chamber 316L –40 76 76 76 200 63 200 (–40) (168.8) (168.8) (168.8) (392) (145.4) (392) A: GT19 two-chamber Plastic PBT –40 (–40) 200 42 200 (392) (107.
Micropilot FMR67 Altitude according to IEC61010-1 Ed.3 • Generally up to 2 000 m (6 600 ft) above MSL. • Above 2 000 m (6 600 ft) if the following conditions are met: – Ordering feature 020 "Power supply; Output" = A, B, C, E or G (2-wire versions) – Supply voltage U < 35 V – Supply voltage of overvoltage category 1 Degree of protection • With closed housing tested according to: – IP68, NEMA6P (24 h at 1.
Micropilot FMR67 Process Process temperature, process pressure The pressure ranges indicated can be reduced by the choice of process connection. The nominal pressure (PN) indicated on the nameplate refers to a reference temperature of 20 °C, and of 100 °F for ASME flanges. Observe pressure-temperature dependency. Please refer to the following standards for the pressure values permitted at higher temperatures: • EN 1092-1: 2001 Tab. 18 In terms of their stability-temperature property, the materials 1.
Micropilot FMR67 FMR67, flush mount antenna, PTFE DN80, standard flange 316L [bar] ([psi]) p 1 2 16 (232) 0 (0) -1 (-14.
Micropilot FMR67 FMR67, PTFE DN80, UNI flange 316L Feature 100 "Process connection" Feature 90 "Seal" • X3J: UNI flange DN200/8"/200A, 316L • X5J: UNI flange DN250/10"/250A, 316L A5, FKM Viton –40 to +150 °C GLT (–40 to +302 °F) 1) Process temperature range A6, FKM Viton –40 to +200 °C GLT (–40 to +392 °F) Process pressure range prel = –1 to 1 bar (–14.5 to 14.
Micropilot FMR67 Mechanical construction Dimensions Dimensions of the electronics housing R100 98 (3.86)* 90 (3.54) 144 (5.67) 141.9 (5.59) ø10 ø108.5 (4.27) 115.25 (4.54) 3.5 (4. 07) 78 (3.07) A0011666 17 Housing GT18 (316L); Dimensions in mm (in) *for devices with integrated overvoltage protection. R100 99.5 (3.92)* 90 (3.54) 144 (5.67) ø106 (4.17) 134.5 (5.3) ø10 6 (4 .17 ) 78 (3.
Micropilot FMR67 FMR67 Drip-off antenna, w/o purge air connection A B ø60 (2.36) 107 (4.21) 20 (0.79) 78 (3.07) 22 (0.87) 205 (8.07) R 127 (5.00) R ø42.5 (1.67) ø42.5 (1.
Micropilot FMR67 FMR67 Drip-off antenna, purge air connection ø100 (3.94) ø60 (2.36) 20 (0.79) 138 (5.43) 47 (1.85) R ø42.5 (1.67) øD A0032154 21 R 42 Dimensions: mm (in) Bottom edge of housing Feature 100: process connection Suitable for øD XJG: UNI flange 3"/DN80/80A, PP • 3" 150lbs • DN80 PN16 • 10K 80A 200 mm (7.87 in) XKG: UNI flange 4"/DN100/100A, PP • 4" 150lbs • DN100 PN16 • 10K 100A 228.
Micropilot FMR67 FMR67 DN80 antenna, purge air connection A B ø80 (3.15) ø60 (2.36) R H 233 (9.17) 162 (6.38) 25.5 (1.00) R ø70 (2.76) øD A0032172 22 A B R Dimensions: mm (in) Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F Bottom edge of housing Feature 100 "Process connection" Endress+Hauser Suitable for Material AGJ: NPS 3" Cl.150 RF, 316/316L ASME B16.5 NPS 3" Cl.150 RF AHJ: NPS 4" Cl.
Micropilot FMR67 FMR67 DN80 antenna, purge air connection, UNI flange 316L A B ø86 (3.39) ø60 (2.36) R 233 (9.17) 8 (0.31) 174 (6.85) 13.5 (0.53) R ø70 (2.
Micropilot FMR67 FMR67 DN80 antenna, purge air connection, UNI flange with alignment device A B ø60 (2.36) R 232 (9.13) 12 (0.47) 163 (6.42) 24 (0.94) R ø70 (2.76) ø95 (3.74) øD A0032173 24 A B R Endress+Hauser Dimensions: mm (in) Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F Bottom edge of housing V. 1, Rev.
Micropilot FMR67 4 × 90° 2 4× ° 1 4×9 0° 90 ° 90 4× ø19 (0.75) A A A ø23 (0.91) ø175 (6.89) ø185.5 (7.3) ø225 (8.86) ø26 (1.02) ø240 (9.45) ø280 (11.02) 4 ø26 (1.02) ° × 6× 12 6 ° 90 × 4 60 ° 3 60 A ø12 (0.47) × 30 ° ø26 (1.02) A A A A A-A ø358 (14.1) ø405 (15.9) 10 (0.39) ø26 (1.02) ø294.5 (11.6) ø340 (13.4) A0032136 Item Feature 100: process connection Suitable for Material 1: XCA: alignment device, UNI 4"/DN100/100A, max 14.
Micropilot FMR67 Weight Housing Part Weight GT18 housing - stainless steel Approx. 4.5 kg (9.9 lb) GT19 housing - plastic Approx. 1.2 kg (2.7 lb) GT20 housing - aluminum Approx. 1.9 kg (4.2 lb) Antenna and process connection Device Antenna 1) Weight of antenna / process connection GA: Drip-off, PTFE DN50 Max. 2 kg (4.4 lb) + flange weight 2) FMR67 GP: Max. 3.5 kg (7.
Micropilot FMR67 Materials: GT18 housing (stainless steel, corrosionresistant) 1 2.1 2.2 5.2 6 5.1 7 4 3 9 8 A0013788 No. Part Material 1 CF3M similar to 316L/1.4404 2.1 Cover of the electronics compartment • • • • • 2.2 Cover of the terminal compartment • Cover: CF3M (similar to 316L/1.4404) • Cover seal: NBR • Thread-coating: Graphite-based lubricant varnish 3 Cover lock • Screw: A4 • Clamp: 316L (1.4404) 4 Lock at the housing neck • Screw: A4-70 • Clamp: 316L (1.
Micropilot FMR67 Materials: GT19 housing (plastic) 1 2.1 2.2 5.2 6 5.1 7 4 3 9 8 A0013788 No. Part Material 1 PBT 2.1 Cover of the electronics compartment • • • • 2.2 Cover of the terminal compartment • Cover: PBT • Cover seal: EPDM • Thread-coating: Graphite-based lubricant varnish 4 • Screw: A4-70 • Clamp: 316L (1.4404) Lock at the housing neck Cover glass: PC Cover frame: PBT-PC Cover seal: EPDM Thread-coating: Graphite-based lubricant varnish 5.
Micropilot FMR67 Materials: GT20 housing (die-cast aluminum, powdercoated, seawater-resistant) 1 2.1 2.2 5.2 6 5.1 7 4 3 9 8 A0013788 50 Nr. Part Material 1 • Housing: AlSi10Mg(<0,1% Cu) • Coating: Polyester Housing, RAL 5012 (blue) 2.1 Cover of the electronics compartment; RAL 7035 (gray) • • • • • Cover: AlSi10Mg(<0,1% Cu) Window: Glass Cover seal: NBR Seal of the window: NBR Thread-coating: Graphite-based lubricant varnish 2.
Micropilot FMR67 Nr. Part Material 8 Ground terminal • • • • 9 Adhesive nameplate Plastic 1) 2) Materials: antenna and process connection Screw: A2 Spring washer: A2 Clamp: 304 (1.4301) Holder: 304 (1.4301) For the version with M12 plug the sealing material is Viton. For the version with 7/8" plug, the sealing material is NBR. FMR67 A B 4 4 3 3 5 6 5 6 2 2 1 1 A0031816 A B Antenna Drip-off DN50 Antenna flush mount DN80 No.
Micropilot FMR67 52 No. Component part Material 1 Antenna PTFE Seals Viton: FKM 2 Flange / process connection Aluminum 3 Antenna adapter, housing adapter 316L / 1.4404 4 Housing seal EPDM 5 Threaded adapter, screw plug Purge air adapter 316L / 1.4404 6 Sensor adapter with alignment device 316L / 1.4404 7 Lock washer 3.1645 / aluminum Threaded fasteners A4-70 A2-70 V. 1, Rev.
Micropilot FMR67 Materials: Weather protection cover 1 2 3 7 4 5 6 A0015473 Endress+Hauser No Part: Material 1 Protection cover: 316L (1.4404) 2 Molded rubber part (4x): EPDM 3 Clamping screw: 316L (1.4404) + carbon fibre 4 Bracket: 316L (1.4404) 5 • Cheese head screw: A4-70 • Nut: A4 • Spring washer: A4 6 Ground terminal • Screw: A4 • Spring washer: A4 • Clamp: 316L (1.4404) • Holder: 316L (1.4404) 7 • Washer: A4 • Cheese head screw: A4-70 V. 1, Rev.
Micropilot FMR67 Operability Operating concept Operator-oriented menu structure for user-specific tasks • Commissioning • Operation • Diagnostics • Expert level Operating languages • English • Deutsch • Français • Español • Italiano • Nederlands • Portuguesa • Polski • русский язык (Russian) • Svenska • Türkçe • 中文 (Chinese) • 日本語 (Japanese) • 한국어 (Korean) • Bahasa Indonesia • tiếng Việt (Vietnamese) • čeština (Czech) Feature 500 of the product structure determines which of these languages is preset on de
Micropilot FMR67 Format for displaying measured variables and status variables can be individually configured Permitted ambient temperature for the display: –20 to +70 °C (–4 to +158 °F) The readability of the display may be impaired at temperatures outside the temperature range.
Micropilot FMR67 Via service interface (CDI) 3 2 1 A0032466 1 2 3 56 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface) Commubox FXA291 Computer with "FieldCare" operating tool V. 1, Rev.
Micropilot FMR67 System integration via Fieldgate Vendor Managed Inventory By using Fieldgates to interrogate tank or silo levels remotely, suppliers of raw materials can provide their regular customers with information about the current supplies at any time and, for example, account for them in their own production planning. For their part, the Fieldgates monitor the configured level limits and, if required, automatically activate the next supply.
Micropilot FMR67 Certificates and approvals CE mark The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the corresponding EC Declaration of Conformity together with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. RoHS The measuring system complies with the substance restrictions of the Restriction on Hazardous Substances Directive 2011/65/EU (RoHS 2).
Micropilot FMR67 Note: A partial examination shall be performed for pressure instruments that are part of safety equipment for the protection of a pipe or vessel from exceeding allowable limits (equipment with safety function in accordance with Pressure Equipment Directive 2014/68/EU, Article 2, point 4).
Micropilot FMR67 Country Name of the station Latitude Longitude Sweden Onsala 57°23'45" North 11°55'35" East Switzerland Bleien 47°20'26" North 08°06'44" East Spain Yebes 40°31'27" North 03°05'22" West Robledo 40°25'38" North 04°14'57" West Penc 47°47'22" North 19°16'53" East Hungary As a general rule, the requirements outlined in EN 302729-1/2 must be observed.
Micropilot FMR67 CRN approval Some device versions have CRN approval. Devices are CRN approved if the following two conditions are met: • The device has a CSA approval (product structure: feature 010 "Approval") • The device has a CRN-approved process connection as per the following table: Feature 100 in the product structure Process connection AGJ NPS 3" Cl.150 RF, 316/316L AHJ NPS 4" Cl.
Micropilot FMR67 Test, certificate Feature 580 "Test, certificate" Description JA 3.1 Material certificate, wetted metal parts, EN10204-3.1 inspection certificate JD 3.1 Material certificate, pressurized parts, EN10204-3.1 inspection certificate KV Declaration of Conformity ASME B31.3: The construction, the material used, the pressure and temperature ranges and the labeling of the devices meet the requirements of ASME B31.
Micropilot FMR67 Other standards and guidelines Endress+Hauser • EN 60529 Degrees of protection provided by enclosures (IP code) • EN 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use • IEC/EN 61326 "Emission in accordance with Class A requirements". Electromagnetic compatibility (EMC requirements).
Micropilot FMR67 Ordering information Ordering information Detailed ordering information is available from the following sources: • In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate" -> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator. • From your Endress+Hauser Sales Center: www.addresses.endress.
Micropilot FMR67 The following points must be considered if option F3 (3-point linearity protocol) was selected in feature 550 ("Calibration"). 3-point linearity protocol The 3 points of the linearity protocol are defined as follows: 1 500 (19.
Micropilot FMR67 The following points must be considered if option F4 (5-point linearity protocol) was selected in feature 550 ("Calibration"). 5-point linearity protocol The 5 points of the linearity protocol are evenly distributed over the measuring range (0% - 100%). Empty calibration (E) and Full calibration (F) must be specified in order to define the measuring range 9).
Micropilot FMR67 Customer-specific configuration Services 10) If the option IJ: "Customized parameterization HART", IK "Customized parameterization PA" or IL "Customized parameterization FF" has been selected in feature 570 "Service", presettings that differ from the default settings can be selected for the following parameters: Parameters Communication protocol Picklist / range of values Setup → Unit of length • HART • PA • FF • • • • Setup → Empty calibration • HART • PA • FF max.
Micropilot FMR67 Application Packages Heartbeat Diagnostics Availability Available in all device versions. Function • Continuous self-monitoring of the device. • Diagnostic messages output to – the local display. – an asset management system (e.g. FieldCare/DeviceCare). – an automation system (e.g. PLC). Advantages • Device condition information is available immediately and processed in time.
Micropilot FMR67 Heartbeat Verification Availability Available for the following options of feature 540 "Application Package": • EH: Heartbeat Verification + Monitoring • EJ: Heartbeat Verification Device functionality checked on demand • • • • Verification of the correct functioning of the measuring device within specifications. The verification result provides information about the condition of the device: Passed or Failed. The results are documented in a verification report.
Micropilot FMR67 Heartbeat Monitoring Availability Available for the following options of feature 540 "Application Package": EH: Heartbeat Verification + Monitoring Function • In addition to the verification parameters, the corresponding parameter values are also logged. • Existing measured variables, such as the echo amplitude, are used in the Foam detection and Build-up detection wizards. The Foam detection and Build-up detection wizards cannot be used together.
Micropilot FMR67 Accessories Device-specific accessories Accessory Weather protection cover Description 222 (8.74) Weather protection cover A0015466 298.5 (11.8) 255.1 (10) 273.7 (10.8) 164 (6.46) b 35° (6.1 156 65° 4) a ° 55 A0015472 29 a b Weather protection cover; Dimensions: mm (in) 37,8 mm (1,5 in) 54 mm (2,1 in) weather protection cover can be ordered together with the device (product structure, feature 620 "Accessory The Enclosed", option PB "Weather Protection Cover").
Micropilot FMR67 Adjustable flange seal Accessories Description 4° Adjustable flange seal ød øD 1 h 2 3 hmin hmax ±8° A0032292 1 2 3 UNI slip-on flange Adjustable flange seal Nozzle material properties and process conditions of the adjustable flange seal must be compatible with the properties The (temperature, pressure, resistance) of the process.
Micropilot FMR67 Accessories Description Technical data: version ASME/JIS Order number 71249070 71249072 71249073 Compatible with • ASME 3" 150lbs • JIS 80A 10K ASME 4" 150lbs ASME 6" 150lbs Recommended screw length Recommended screw size 100 mm (3.9 in) 100 mm (3.9 in) 110 mm (4.3 in) M14 M14 M18 Material EPDM Process pressure –0.1 to 0.1 bar (–1.45 to 1.45 psi) Process temperature Endress+Hauser –40 to +80 °C (–40 to +176 °F) D 133 mm (5.2 in) 171 mm (6.7 in) 219 mm (8.
Micropilot FMR67 Mounting bracket adjustable Accessories Description Mounting bracket adjustable 99.5 (3.9) 260 (10.2) 48(1.9) 122 (4.8) 65 (2.6) ø9(0.4) 9(0.4) 12(0.5) 35(1.4) 100 (3.9) 16 (0.6) A0032295 Material: 304 (1.
Micropilot FMR67 Remote display FHX50 Accessories Description Remote display FHX50 1. 2. 3. 4. A0019128 • Material: – Plastic PBT – 316L/1.
Micropilot FMR67 Overvoltage protection Accessory Description Overvoltage protection for 2-wire-devices OVP10 (1 channel) OVP20 (2 channel) A0021734 Technical data • Resistance per channel: 2 * 0.5 Ωmax • Threshold DC voltage: 400 to 700 V • Threshold impulse voltage: < 800 V • Capacitance at 1 MHz: < 1.5 pF • Nominal arrest impulse voltage (8/20 μs): 10 kA • Suited for wire cross-sections: 0.2 to 2.
Micropilot FMR67 Communication-specific accessories Accessory Description Commubox FXA195 HART For intrinsically safe HART communication with FieldCare via the USB interface. Accessory Description Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a computer.
Micropilot FMR67 Accessory Description Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It enables efficient device configuration and diagnostics for HART and FOUNDATION fieldbus devices in the non-Ex area. For details, see Operating Instructions BA01202S Accessory Description Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance.
Micropilot FMR67 Supplementary documentation For an overview of the scope of the associated Technical Documentation, refer to the following: • The W@M Device Viewer: enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. The following document types are available: In the Download Area of the Endress+Hauser Internet site: www.endress.
Micropilot FMR67 Feature 010 Approval Feature 020 "Power Supply; Output" B 2) C 3) E 4)/G 5) K 6)/L 7) * 8) * 8) * 8) * 8) - 8) 8) 8) 8) - A FA FB FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 Div.2 * FC FM XP Cl.I Div.1 Gr.A-D * 8) * 8) * 8) * 8) * 8) FD FM XP Cl.I,II,III Div.1 Gr.A-G, AEx db, NI Cl.1 Div.2 * 8) * 8) * 8) * 8) * 8) FE FM DIP Cl.II,III Div.1 Gr.
Micropilot FMR67 Feature 010 Approval Feature 020 "Power Supply; Output" A 1) 2) 3) 4) 5) 6) 7) 8) 1) B 2) C 3) E 4)/G 5) K 6)/L 7) N3 NEPSI Ex d[ia] IIC T6 Ga/Gb, DIP A20/21 T85…90oC IP66 * 8) * 8) * 8) * 8) * 8) 8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G * 8) * 8) * 8) * 8) - 2-wire; 4-20mA HART 2-wire; 4-20mA HART, switch output 2-wire; 4-20mA HART, 4-20mA 2-wire; FOUNDATION Fieldbus, switch output 2-wire; PROFIBUS PA, switch output 4-wire 90-253VAC; 4-20mA HART 4-wire 10.
www.addresses.endress.