unbekannt unbekannt Products Solutions Services Technical Information Micropilot FMR60B HART Free space radar Level measurement in liquids Application • • • • • • Continuous, non-contact level measurement of liquids, pastes and sludges Process connections: Thread or mounting bracket Maximum measuring range: 50 m (164 ft) Temperature: –40 to +200 °C (–40 to +392 °F) Pressure: –1 to +20 bar (–14.5 to +290 psi) Accuracy: ±1 mm (±0.
Micropilot FMR60B HART Table of contents Important document information . . . . . . . . . . . . . . . 4 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Graphic conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Process pressure range . . . . . . . . . . . . . . . . . . . . . . . . . 35 Dielectric constant . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Micropilot FMR60B HART Memograph M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RN42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 62 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Document function . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 63 Endress+Hauser V. 1, Rev.
Micropilot FMR60B HART Important document information Symbols Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury.
Micropilot FMR60B HART • Installation, explosion and electrical connection drawings are presented in simplified format • Devices, assemblies, components and dimensional drawings are presented in reduced-line format • Dimensional drawings are not to-scale representations; the dimensions indicated are rounded off to 2 decimal places • Unless otherwise described, flanges are presented with sealing surface form EN1091-1, B2; ASME B16.
Micropilot FMR60B HART D = (c ∆t) / 2 where c is the speed of propagation of the wave. In summary, D can be calculated from the measured difference frequency Δf. D is then used to determine the content of the tank or silo. Input Measured variable The measured variable is the distance between the reference point and the product surface. The level is calculated based on "E", the empty distance entered. Measuring range The measuring range starts at the point where the beam hits the tank floor.
A Micropilot FMR60B HART B H 100% 0% C A0031828 A B C H Antenna tip + 10 mm (0.4 in) Smallest possible measuring range Distance above tank floor = 50 to 80 mm (1.97 to 3.15 in); (water-based medium εr = 2) Vessel height > 0.7 m (2.3 ft) The media groups and the possible measuring range are described as a function of the application and media group in the following section. If the dielectric constant of the medium is not known, to ensure a reliable measurement assume the medium belongs to group B.
Micropilot FMR60B HART Integrated antenna, PEEK, 20 mm (0.75 in) in storage vessel Media group Measuring range A0 (εr 1.2 to 1.4) 1.5 m (5 ft) A (εr 1.4 to 1.9) 2.5 m (8 ft) B (εr 1.9 to 4) 5 m (16 ft) C (εr 4 to 10) 8 m (26 ft) D (εr >10) 10 m (33 ft) Integrated antenna, PEEK, 40 mm (1.5 in) in storage vessel Media group Measuring range A0 (εr 1.2 to 1.4) 3 m (10 ft) A (εr 1.4 to 1.9) 6 m (20 ft) B (εr 1.
Micropilot FMR60B HART PTFE Drip-off antenna, 50 mm (2 in) in storage vessel Media group Measuring range A0 (εr 1.2 to 1.4) 7 m (23 ft) A (εr 1.4 to 1.9) 12 m (39 ft) B (εr 1.9 to 4) 23 m (75 ft) C (εr 4 to 10) 40 m (131 ft) D (εr >10) 50 m (164 ft) Measurement in buffer vessel Buffer vessel - measuring conditions Moving medium surface (e.g. permanent free filling from above, mixing jets) Integrated antenna, PEEK, 40 mm (1.5 in) in buffer vessel Media group Measuring range A0 (εr 1.2 to 1.
Micropilot FMR60B HART PTFE Drip-off antenna, 50 mm (2 in) in buffer vessel Media group Measuring range A0 (εr 1.2 to 1.4) 4 m (13 ft) A (εr 1.4 to 1.9) 7 m (23 ft) B (εr 1.9 to 4) 13 m (43 ft) C (εr 4 to 10) 28 m (92 ft) D (εr >10) 44 m (144 ft) Measurement in vessel with agitator Vessel with agitator - measuring conditions Turbulent medium surface (e.g. from filling from above, stirrers and baffles) Integrated antenna, PEEK, 20 mm (0.
Micropilot FMR60B HART Encapsulated antenna, PVDF, 40 mm (1.5 in) in vessel with agitator Media group Measuring range A0 (εr 1.2 to 1.4) 1 m (3.3 ft) A (εr 1.4 to 1.9) 1.5 m (5 ft) B (εr 1.9 to 4) 3 m (10 ft) C (εr 4 to 10) 7 m (23 ft) D (εr >10) 11 m (36 ft) PTFE Drip-off antenna, 50 mm (2 in) in vessel with agitator Operating frequency Media group Measuring range A0 (εr 1.2 to 1.4) 2 m (7 ft) A (εr 1.4 to 1.9) 4 m (13 ft) B (εr 1.
Micropilot FMR60B HART The current output offers a choice of three different operating modes: • 4.0 to 20.5 mA • NAMUR NE 43: 3.8 to 20.5 mA (factory setting) • US mode: 3.9 to 20.8 mA Signal on alarm Current output Failure mode (according to NAMUR Recommendation NE 43): • Minimum alarm (= factory setting): 3.
Micropilot FMR60B HART Device type ID: 0x11C1 Device revision: 1 HART specification: 7 DD version: 1 Device description files (DTM, DD) Information and files under: • www.endress.com On the product page for the device: Documents/Software → Device drivers • www.fieldcommgroup.org HART load: Min.
Micropilot FMR60B HART Multidrop current: 4 mA Time to establish connection: < 30 s Power supply Terminal assignment Single compartment housing 3 2 - 1 + A0042594 3 1 2 3 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Dual compartment housing - + 3 2 1 A0042803 4 1 2 3 14 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal V.
Micropilot FMR60B HART Dual compartment housing, L-form - + 3 2 1 A0045842 5 1 2 3 Terminals Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal • Supply voltage and internal ground terminal: 0.5 to 2.5 mm2 (20 to 14 AWG) • External ground terminal: 0.5 to 4 mm2 (20 to 12 AWG) In the case of devices with a plug, it is not necessary to open the housing for connection purposes.
Micropilot FMR60B HART Measuring devices with Harting plug Han7D A – B + 8 + – 7 6 1 2 5 3 4 Han7D + – A0041011 A B + Electrical connection for devices with Harting plug Han7D View of the plug-in connection on the device Brown Green/yellow Blue Material CuZn, gold-plated plug-in jack and plug contacts Supply voltage The supply voltage depends on the selected type of device approval Non-hazardous, Ex d, Ex e 10.5 to 35 VDC Ex i 10.
Micropilot FMR60B HART LWARNING Explosion Hazard! ‣ Please refer to the separate documentation on applications in hazardous areas for the safety instructions. For optimum electromagnetic compatibility: • Keep the potential matching line as short as possible • Observe a cross-section of at least 2.
Micropilot FMR60B HART Overvoltage category Overvoltage category II Performance characteristics Reference operating conditions • • • • • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F) Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi) Humidity = 60 % ±15 % Reflector: metal plate with diameter ≥ 1 m (40 in) No major interference reflections inside the signal beam Maximum measured error Reference accuracy Accuracy The accuracy is the sum of the non-linearity, non-repeatability and hysteresis.
Micropilot FMR60B HART The following step response times apply (in accordance with DIN EN IEC 61298-2 / DIN EN IEC 60770-1) when damping is switched off: • Pulse frequency ≥ 5/s (cycle time ≤ 200 ms) at U= 10.5 to 35 V, I= 4 to 20 mA and Tamb= –50 to +80 °C (–58 to +176 °F) • Step response time < 1 s Influence of ambient temperature The output changes due to the effect of the ambient temperature with respect to the reference temperature.
Micropilot FMR60B HART Mounting Mounting location 1 2 3 A A0016882 A 1 2 3 Orientation Recommended distance from wall to nozzle outer edge ~ 1/6 of the vessel diameter. The device should never be mounted closer than 15 cm (5.91 in) to the tank wall.
Micropilot FMR60B HART Avoiding interference echoes A0031813 Metal deflector plates, installed at an angle to scatter the radar signals, help prevent interference echoes. Vertical alignment of antenna axis Align the antenna so that it is perpendicular to the product surface. The maximum reach of the antenna can be reduced, or additional interference signals can occur, if the antenna is not installed perpendicular to the product.
Micropilot FMR60B HART PTFE Drip-off antenna 50 mm (2 in) Information about the mounting nozzle The maximum nozzle length Hmax depends on the nozzle diameter D. H max Maximum nozzle length Hmax as a function of the nozzle diameter D D Hmax 50 to 80 mm (2 to 3.2 in) 750 mm (30 in) 80 to 100 mm (3.2 to 4 in) 1 150 mm (46 in) 100 to 150 mm (4 to 6 in) 1 450 mm (58 in) ≥150 mm (6 in) 2 200 mm (88 in) øD In the case of longer nozzles, reduced measuring performance must be expected.
Micropilot FMR60B HART H max Maximum nozzle length Hmax as a function of the nozzle diameter D øD ØD Hmax 40 to 50 mm (1.6 to 2 in) 400 mm (16 in) 50 to 80 mm (2 to 3.2 in) 550 mm (22 in) 80 to 100 mm (3.2 to 4 in) 850 mm (34 in) 100 to 150 mm (4 to 6 in) 1 050 mm (42 in) ≥150 mm (6 in) 1 600 mm (64 in) In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs.
Micropilot FMR60B HART Drip-off, PTFE 50 mm (2 in) antenna, α = 6 ° D W = D × 0.10 α W D W 5 m (16 ft) 0.52 m (1.70 ft) 10 m (33 ft) 1.04 m (3.41 ft) 15 m (49 ft) 1.56 m (5.12 ft) 20 m (66 ft) 2.08 m (6.82 ft) 25 m (82 ft) 2.60 m (8.53 ft) 30 m (98 ft) 3.12 m (10.24 ft) 35 m (115 ft) 3.64 m (11.94 ft) 40 m (131 ft) 4.16 m (13.65 ft) 45 m (148 ft) 4.68 m (15.35 ft) 50 m (164 ft) 5.20 m (17.06 ft) Integrated antenna, PEEK 20 mm / 3/4", α 14 ° D W 5 m (16 ft) 1.23 m (4.
Micropilot FMR60B HART Special mounting instructions Measurement through a ball valve A0034564 • Measurements can be performed through an open full bore ball valve without any problems. • At the transitions, no gap exceeding 1 mm (0.04 in) may be left. • Opening diameter of ball valve must always correspond to the pipe diameter; avoid edges and constrictions.
Micropilot FMR60B HART If process temperatures are high, the device should be included in the usual container insulation system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The rib structure (1) must not be insulated. Environment Ambient temperature range The following values apply up to a process temperature of +85 °C (+185 °F). At higher process temperatures, the permitted ambient temperature is reduced.
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0048826 9 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: 0 to +150 °C (+32 to +302 °F) with CSA C/US approval = = = = = Tp: Tp: Tp: Tp: Tp: 0 °C (+32 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +150 °C (+302 °F) | Ta: +25 °C (+77 °F) +150 °C (+302 °F) | Ta: 0 °C (+32 °F) 0 °C (+32 °F) | Ta: 0 °C (+32 °F) Order option; process temperature range: –20 to +200 °C (–4 to +392 °F) Ta P1 P2 P3 P5 P4 Tp A0032024
Micropilot FMR60B HART Ta P1 P2 P3 P5 Tp P4 A0032024 12 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +80 °C (–40 to +176 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +80 °C (+176 °F) | Ta: +75 °C (+167 °F) +80 °C (+176 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature range of –40 to
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0048826 15 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: 0 to +130 °C (+32 to +266 °F) with CSA C/US approval = = = = = Tp: Tp: Tp: Tp: Tp: 0 °C (+32 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +130 °C (+266 °F) | Ta: +52 °C (+126 °F) +130 °C (+266 °F) | Ta: 0 °C (+32 °F) 0 °C (+32 °F) | Ta: 0 °C (+32 °F) Process temperature range: –40 to +150 °C (–40 to +302 °F) Ta P1 P2 P3 P5 Tp P4 A0032024 16 P1
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 18 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +200 °C (–40 to +392 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +200 °C (+392 °F) | Ta: +27 °C (+81 °F) +200 °C (+392 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature range of –40 to
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 21 P1 P2 P3 P4 P5 = = = = = Aluminum housing material; process temperature range: –20 to +200 °C (–4 to +392 °F) Tp: Tp: Tp: Tp: Tp: –20 °C (–4 °F) | Ta: +79 °C (+174 °F) +79 °C (+174 °F) | Ta: +79 °C (+174 °F) +200 °C (+392 °F) | Ta: +47 °C (+117 °F) +200 °C (+392 °F) | Ta: –20 °C (–4 °F) –20 °C (–4 °F) | Ta: –20 °C (–4 °F) Order option; process temperature range: –40 to +80 °C (–40 to +176 °F) Ta P1 P2 P3 P5 P4 Tp A0032024 22 P1 P2 P3
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 24 P1 P2 P3 P4 P5 = = = = = Aluminum housing material; process temperature range: –40 to +150 °C (–40 to +302 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +79 °C (+174 °F) +79 °C (+174 °F) | Ta: +79 °C (+174 °F) +150 °C (+302 °F) | Ta: +53 °C (+127 °F) +150 °C (+302 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Order option; process temperature range: –40 to +200 °C (–40 to +392 °F) Ta P1 P2 P3 P5 P4 Tp A0032024 25 P1
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 27 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –20 to +200 °C (–4 to +392 °F) Tp: Tp: Tp: Tp: Tp: –20 °C (–4 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +200 °C (+392 °F) | Ta: +38 °C (+100 °F) +200 °C (+392 °F) | Ta: –20 °C (–4 °F) –20 °C (–4 °F) | Ta: –20 °C (–4 °F) Order option; process temperature range: –40 to +80 °C (–40 to +176 °F) Ta P1 P2 P3 P5 P4 Tp A0032024 28 P1 P2 P3 P4
Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 30 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –40 to +200 °C (–40 to +392 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +200 °C (+392 °F) | Ta: +38 °C (+100 °F) +200 °C (+392 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Storage temperature • Without LCD display: –40 to +90 °C (–40 to +194 °F) • With LCD display: –40 to +85 °C (–40 to +1
Micropilot FMR60B HART Process Process pressure range LWARNING The maximum pressure for the device depends on the lowest-rated component with regard to pressure (components are: process connection, optional mounted parts or accessories). ‣ Only operate the device within the specified limits for the components! ‣ MWP (Maximum Working Pressure): The MWP is specified on the nameplate. This value refers to a reference temperature of +20 °C (+68 °F) and may be applied to the device for an unlimited time.
Micropilot FMR60B HART Process connection UNI flange PP Seal Tp Process pressure range FKM Viton GLT –40 to +80 °C (–40 to +176 °F) –1 to 3 bar (–14.5 to 43.5 psi) EPDM –40 to +80 °C (–40 to +176 °F) –1 to 3 bar (–14.5 to 43.5 psi) The following temperature restriction applies for devices with the HNBR or FFKM Kalrez O-ring A0047726 HNBR –20 to +80 °C (–4 to +176 °F) –1 to 3 bar (–14.5 to 43.5 psi) FFKM Kalrez –20 to +80 °C (–4 to +176 °F) –1 to 3 bar (–14.5 to 43.
Micropilot FMR60B HART Contact Endress+Hauser for applications with lower dielectric constants than indicated. Mechanical construction The dimensions of the individual components must be added together for the total dimensions. Dimensions Plastic single compartment housing !94 (3.7) 2 123.9 (4.88) 125.3 (4.93) 1 107.5 (4.23) A0048768 31 1 2 Endress+Hauser Dimensions of single compartment housing, plastic (PBT) Height with cover with plastic viewing window Cover without viewing window V.
Micropilot FMR60B HART Aluminum single compartment housing !101 (3.98) 1 3 124 (4.88) 127 (5) 138 (5.43) 2 45 (1.77) 125 (4.92) ESC - + E A0038380 32 1 2 3 38 Dimensions of aluminum single compartment housing Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window V. 1, Rev.
Micropilot FMR60B HART Dual compartment housing 132 (5.2) 121 (4.76) 115 (4.53) 118 (4.65) 131 (5.16) 127 (5) 2 !101 (3.98) 3 ESC - + E 1 64 (2.52) 54 (2.13) 78 (3.07) 143 (5.63) A0038377 33 1 2 3 Endress+Hauser Dimensions of dual compartment housing Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window V. 1, Rev.
Micropilot FMR60B HART Dual compartment housing, L-form 133 (5.24) 130 (5.12) 110 (4.33) 3 2 144 (5.67) !101 (3.98) !101 (3.98) 1 140 (5.51) 138 (5.43) ESC - + E A0038381 34 1 2 3 Dimensions of dual compartment housing, L-form Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window Encapsulated antenna, PVDF, 40 mm (1.5 in) R 105.4 (4.15) 50 mm 72.2 (2.84) 50.2 (1.98) 1 !43.7 (1.
Micropilot FMR60B HART Encapsulated antenna, PVDF, 40 mm (1.5 in), process connection UNI flange 72.2 (2.84) 50 mm R 105.4 (4.15) 52.2 (2.06) 1 !43.7 (1.72) A0048829 36 R 1 Dimensions of encapsulated antenna, PVDF, 40 mm (1.5 in), process connection UNI flange. Unit of measurement mm (in) Reference point of measurement Bottom edge of housing UNI flange 3"/DN80/80A G 1 1/2 !200 (7.9) !160 (6.3) !150 (5.9) 19 (0.75) 45° 20 (0.79) A0048847 37 Dimensions of UNI flange 3"/DN80/80A.
Micropilot FMR60B HART UNI flange 4"/DN100/100A G 1 1/2 !228.6 (9) !190.5 (7.5) !175 (6.9) 19 (0.75) 45° 20 (0.79) A0048848 38 Dimensions of UNI flange 4"/DN100/100A. Unit of measurement mm (in) Suitable for ASME B16.5, 4" 150lbs / EN1092-1; DN100 PN16 / JIS B2220; 10K 100A Material: PP, weight 0.70 kg (1.54 lb) UNI flange 6"/DN150/150A G 1 1/2 !285 (11.2) !241.3 (9.5) !240 (9.4) 23 (0.9) 45° 20 (0.79) A0048849 39 Dimensions of UNI flange 6"/DN150/150A.
Micropilot FMR60B HART Drip-off antenna 50 mm (2 in), threaded process connection A B 1 L2 22 (0.87) L1 1 R 78 (3.07) 55 mm !42.5 (1.67) A0046479 40 A B 1 R L1 L2 Endress+Hauser Dimensions of Drip-off antenna 50 mm (2 in), threaded process connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Bottom edge of housing Reference point of measurement 97 mm (3.82 in); version with Ex d or XP approval +5 mm (+0.
Micropilot FMR60B HART Drip-off antenna 50 mm (2 in), UNI flange process connection A B 1 L1 L4 L2 L3 1 78 (3.07) R !42.5 (1.67) A0046480 41 A B 1 R L1 L2 L3 L4 Dimensions of Drip-off antenna 50 mm (2 in), UNI flange process connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Bottom edge of housing Reference point of measurement 175 mm (6.89 in); version with Ex d or XP approval +5 mm (+0.20 in) 77 mm (3.
Micropilot FMR60B HART UNI flange 4"/DN100/100A G 1 1/2 !228.6 (9) !190.5 (7.5) !175 (6.9) 19 (0.75) 45° 20 (0.79) A0048848 43 Dimensions of UNI flange 4"/DN100/100A. Unit of measurement mm (in) Suitable for ASME B16.5, 4" 150lbs / EN1092-1; DN100 PN16 / JIS B2220; 10K 100A Material: • PP, weight 0.70 kg (1.54 lb) • 316L, weight 5.80 kg (12.79 lb) UNI flange 6"/DN150/150A G 1 1/2 !285 (11.2) !241.3 (9.5) !240 (9.4) 23 (0.9) 45° 20 (0.
Micropilot FMR60B HART Integrated antenna, PEEK, 20 mm (0.75 in) A B 1 36 mm 22 (0.87) L1 L2 1 R !23.8 (0.94) !32.2 (1.27) A0046481 45 A B R 1 L1 L2 46 Dimensions; integrated antenna, PEEK, 20 mm (0.75 in); process connection, thread 3/4". Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Reference point of measurement Bottom edge of housing 112 mm (4.41 in); version with Ex d or XP approval +5 mm (+0.20 in) 124 mm (4.
Micropilot FMR60B HART Integrated antenna, PEEK, 40 mm (1.5 in) A 1 B 30 (1.18) L1 L2 1 R !42.5 (1.67) !54.8 (2.18) A0046482 46 A B R 1 L1 L2 Weight Dimensions; integrated antenna, PEEK, 40 mm (1.5 in); process connection, thread 1-1/2". Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Reference point of measurement Bottom edge of housing 153 mm (6.02 in); version with Ex d or XP approval +5 mm (+0.20 in) 165 mm (6.
Micropilot FMR60B HART Materials Materials not in contact with process Plastic housing • • • • • • • • • • • • • Housing: PBT/PC Blind cover: PBT/PC Transparent cover: PA12 Cover with viewing window: PBT/PC and PC Cover seal: EPDM Potential equalization: 316L Seal under potential equalization: EPDM Plug: PBT-GF30-FR M20 cable gland: PA Seal on plug and cable gland: EPDM Threaded adapter as replacement for cable glands: PA66-GF30 Nameplate: plastic foil TAG plate: plastic foil, metal or provided by the cu
Micropilot FMR60B HART Drip-off antenna 50 mm (2 in) 4 5 6 3 2 1 A0046603 48 1 2 3 4 5 6 Material; Drip-off antenna 50 mm (2 in) Antenna: PTFE, seal material can be selected (order option) Threaded sleeve: 316L / 1.4404 Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404 Synthetic/organic fiber elastomer seal (asbestos-free), FA material UNI flange, material can be selected (order option) Integrated antenna, PEEK, 20 mm (0.
Micropilot FMR60B HART Integrated antenna, PEEK, 40 mm (1.5 in) 3 2 1 A0046606 50 1 2 3 Material; integrated antenna, PEEK, 40 mm (1.5 in) Antenna: PEEK, seal material can be selected (order option) Process connection: 316L / 1.4404 Housing adapter: 316L / 1.
Micropilot FMR60B HART • • • • • • • • Local operation русский язык (Russian) Türkçe 中文 (Chinese) 日本語 (Japanese) 한국어 (Korean) tiếng Việt (Vietnamese) čeština (Czech) Svenska Operating keys and DIP switches on the HART electronic insert off on 1 2 off on Display 4 3 A0046129 51 1 1+2 2 3 4 Operating keys and DIP switches on the HART electronic insert Operating key for reset password (for Bluetooth login and Maintenance user role) Operating keys for device reset (as-delivered state) Operating k
Micropilot FMR60B HART Remote operation Via HART protocol Via service interface (CDI) Operation via Bluetooth® wireless technology (optional) Prerequisite • Measuring device with display including Bluetooth • Smartphone or tablet with Endress+Hauser SmartBlue app or PC with DeviceCare from version 1.07.05 or FieldXpert SMT70 The connection has a range of up to 25 m (82 ft). The range can vary depending on environmental conditions such as attachments, walls or ceilings.
Micropilot FMR60B HART Explosion-protected smartphones and tablets If used in hazardous areas, mobile end devices with an Ex approval must be used. Functional safety Use for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous or diverse redundancy), independently evaluated by TÜV Rheinland in accordance with IEC 61508, refer to the "Functional Safety Manual" for information.
Micropilot FMR60B HART Country Name of the station Latitude Longitude Sardinia 39° 29' 50" North 09° 14' 40" East Poland Fort Skala Krakow 50° 03' 18" North 19° 49' 36" East Russia Dmitrov 56° 26' 00" North 37° 27' 00" East Kalyazin 57° 13' 22" North 37° 54' 01" East Pushchino 54° 49' 00" North 37° 40' 00" East Zelenchukskaya 43° 49' 53" North 41° 35' 32" East Sweden Onsala 57° 23' 45" North 11° 55' 35" East Switzerland Bleien 47° 20' 26" North 08° 06' 44" East Spain Yebes
Micropilot FMR60B HART • The installation of the LPR/TLPR device shall be done by trained installers, in strict compliance with the manufacturer’s instructions. • The use of this device is on a “no-interference, no-protection” basis. That is, the user shall accept operations of high-powered radar in the same frequency band which may interfere with or damage this device. However, devices found to interfere with primary licensing operations will be required to be removed at the user’s expense.
Micropilot FMR60B HART A R F E 100% 0% A0032643 R A E F Reference point of measurement Minimum distance between reference point R and 100% mark Empty calibration Full calibration Measuring range restrictions The following restrictions must be considered when selecting E and F: • Minimum distance between reference point R and 100% mark A ≥ antenna length + 200 mm (8 in) Minimum value: 400 mm (16 in) • Minimum span F ≥ 400 mm (16 in) • Maximum value for Empty calibration E ≤ 30 m (98 ft) • The linear
Micropilot FMR60B HART • • • • • • • • RFID TAG + paper adhesive label RFID TAG + TAG provided by the customer DIN91406 stainless steel TAG DIN91406 stainless steel TAG + NFC TAG DIN91406 stainless steel TAG, stainless steel TAG DIN91406 stainless steel TAG + NFC, stainless steel TAG DIN91406 stainless steel TAG, plate supplied DIN91406 stainless steel TAG + NFC, plate supplied Definition of tag name Specify in the additional specification: 3 lines with a maximum of 18 characters per line The specified t
Micropilot FMR60B HART "Foam detection" wizard This wizard configures the automatic foam detection. Foam detection can be linked to a output variable or status information e.g. to control a sprinkler used to dissolve the foam. It is also possible to monitor the foam increase in a so called foam index. The foam index can also be linked to a output variable and can be shown on the display. Preparation: The Foam monitoring initialization should only be done without or less foam.
Micropilot FMR60B HART Material • Weather protection cover: 316L • Clamping screw: A4 • Holder: 316L Order number for accessories: 71438303 Plastic weather protection cover The weather protection cover can be ordered together with the device via the "Accessory enclosed" product structure. It is used to protect against direct sunlight, precipitation and ice. The plastic weather protection cover is suitable for the single compartment housing made of aluminum.
Micropilot FMR60B HART 156 (6.14) 9 (0.35) 3 (0.12) 282 (11.1) 230 (9.06) 35 (1.38) 65 (2.56) 6 (0.24) 32.5 (1.28) !9 (0.35) A0048769 56 Dimensions of mounting bracket. Unit of measurement mm (in) Scope of delivery: • 1 × mounting bracket, 316L (1.4404) • 2 × holder, 316L (1.4404) • 6 × screws, A4 • 4 × lock washer, A4 Suitable for device with: • Single compartment housing • Dual compartment housing, L-form and: • Encapsulated antenna, PVDF, 40 mm (1.
Micropilot FMR60B HART M12 socket, angled, 5 m (16 ft) cable • M12 socket material: • Body: TPU • Union nut: nickel-plated die-cast zinc • Cable material: PVC • Cable Li Y YM 4×0.34 mm2 (20 AWG) • Cable colors • 1 = BN = brown • 2 = WH = white • 3 = BU = blue • 4 = BK = black • Order number: 52010285 Remote display FHX50B The remote display is ordered via the Product Configurator. If the remote display is to be used, the device version Prepared for display FHX50B must be ordered.
Micropilot FMR60B HART Commubox FXA195 HART For intrinsically safe HART communication with FieldCare via the USB interface For details, see "Technical Information" TI00404F HART Loop Converter HMX50 Is used to evaluate and convert dynamic HART process variables to analog current signals or limit values.
Micropilot FMR60B HART Documentation For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.
*unbekannt* unbekannt www.addresses.endress.