BA02247F/00/EN/01.22-00 71575911 2022-08-01 Products Solutions 01.00.
Micropilot FMR60B HART 1. Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number 2. www.endress.com/deviceviewer Endress+Hauser Operations App 3.
Micropilot FMR60B HART Table of contents Table of contents 1 Document information . . . . . . . . . . . . . . 5 1.1 1.2 1.4 1.5 Purpose of this document . . . . . . . . . . . . . . . . . Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Safety symbols . . . . . . . . . . . . . . . . . . 1.2.2 Symbols for certain types of information and graphics . . . . . . . . . . . Documentation . . . . . . . . . . . . . . . . . . . . . . . . 1.3.1 Technical Information (TI) . . . . . . . . .
Table of contents Micropilot FMR60B HART 9 Commissioning . . . . . . . . . . . . . . . . . . . . 35 13 9.1 9.2 9.3 13.1 9.7 9.8 Preliminaries . . . . . . . . . . . . . . . . . . . . . . . . Function check . . . . . . . . . . . . . . . . . . . . . . . Establishing a connection via FieldCare and DeviceCare . . . . . . . . . . . . . . . . . . . . . . . . . . 9.3.1 Via HART protocol . . . . . . . . . . . . . . . 9.3.2 Via service interface (CDI) . . . . . . . . .
Micropilot FMR60B HART Document information 1 Document information 1.1 Purpose of this document These Operating Instructions contain all the information that is required in the various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal. 1.2 Symbols 1.2.1 Safety symbols DANGER This symbol alerts you to a dangerous situation.
Document information Micropilot FMR60B HART Write-protected parameter 1, 2, 3, ... Item numbers A, B, C, ... Views Safety instructions Observe the safety instructions contained in the associated Operating Instructions 1.3 Documentation The following types of documentation are available in the Download Area of the Endress +Hauser website (www.endress.com/downloads): For an overview of the scope of the associated Technical Documentation, refer to the following: • Device Viewer (www.endress.
Micropilot FMR60B HART Document information TI Document type "Technical Information" SD Document type "Special Documentation" XA Document type "Safety Instructions" PN Nominal pressure MWP Maximum working pressure The MWP is indicated on the nameplate.
Basic safety instructions Micropilot FMR60B HART 2 Basic safety instructions 2.1 Requirements for personnel The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Personnel must be authorized by the plant owner/operator. ‣ Be familiar with federal/national regulations.
Micropilot FMR60B HART Basic safety instructions Danger of burns from contact with surfaces! ‣ For elevated fluid temperatures, ensure protection against contact to prevent burns. 2.3 Workplace safety When working on and with the device: ‣ Wear the required personal protective equipment according to federal/national regulations. ‣ Switch off the supply voltage before connecting the device. 2.
Basic safety instructions Micropilot FMR60B HART operators' security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves. 2.8 Device-specific IT security The device offers specific functions to support protective measures by the operator. These functions can be configured by the user and guarantee greater in-operation safety if used correctly.
Micropilot FMR60B HART Product description 3 Product description 3.1 Product design 1 2 4 3 5 A0046661 1 1 2 3 4 5 Endress+Hauser Design of the Micropilot FMR60B Electronics housing Encapsulated antenna, PVDF, 40 mm (1.5 in) Drip-off antenna 50 mm (2 in) - threaded or UNI flange process connection Integrated antenna, PEEK, 20 mm (0.75 in) Integrated antenna, PEEK, 40 mm (1.
Incoming acceptance and product identification Micropilot FMR60B HART 4 Incoming acceptance and product identification 4.
Micropilot FMR60B HART Incoming acceptance and product identification 4.2.2 Manufacturer address Endress+Hauser SE+Co. KG Hauptstraße 1 79689 Maulburg, Germany Place of manufacture: See nameplate. 4.3 Storage and transport 4.3.1 Storage conditions • Use the original packaging • Store the device in clean and dry conditions and protect from damage caused by shocks Storage temperature range See Technical Information. 4.3.
Mounting Micropilot FMR60B HART 5 Mounting 5.1 General instructions LWARNING Loss of protection rating if the device is opened in a wet environment. ‣ Only open the device in a dry environment! 1. Install the device or turn the housing so that the cable entries do not point upwards. A0029263 2. Always firmly tighten the housing cover and the cable entries. 3. Counter-tighten the cable entries. 4. A drip loop must be provided when laying the cables. 5.2 Mounting requirements 5.2.
Micropilot FMR60B HART Mounting 5.2.2 Avoiding interference echoes A0031813 Metal deflector plates, installed at an angle to scatter the radar signals, help prevent interference echoes. 5.2.3 Vertical alignment of antenna axis Align the antenna so that it is perpendicular to the product surface. The maximum reach of the antenna can be reduced, or additional interference signals can occur, if the antenna is not installed perpendicular to the product. 5.2.
Mounting Micropilot FMR60B HART H max Maximum nozzle length Hmax as a function of the nozzle diameter D D Hmax 50 to 80 mm (2 to 3.2 in) 600 mm (24 in) 80 to 100 mm (3.2 to 4 in) 1 000 mm (24 in) 100 to 150 mm (4 to 6 in) 1 250 mm (50 in) ≥ 150 mm (6 in) 1 850 mm (74 in) øD In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs. • The edge of the nozzle should be rounded.
Micropilot FMR60B HART Mounting 5.3.3 Integrated antenna, PEEK 20 mm (0.75 in) Information concerning threaded connections • When screwing in, turn by the hex bolt only. • Tool: open-ended wrench 36 mm • Maximum permissible torque: 50 Nm (36 lbf ft) Information about the mounting nozzle The maximum nozzle length Hmax depends on the nozzle diameter D. H max Maximum nozzle length Hmax as a function of the nozzle diameter D øD D Hmax 40 to 50 mm (1.6 to 2 in) 200 mm (8 in) 50 to 80 mm (2 to 3.
Mounting Micropilot FMR60B HART ØD Hmax 100 to 150 mm (4 to 6 in) 1 050 mm (42 in) ≥150 mm (6 in) 1 600 mm (64 in) In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs. • The edge of the nozzle should be rounded. • Mapping must be performed. • Please contact the manufacturer's support department for applications with nozzles that are higher than indicated in the table. 5.3.
Micropilot FMR60B HART Mounting 3. 1. 4 0.7 Nm 2. 4. A0038224 1. If fitted: release the screw of the cover lock for the electronics compartment cover using the Allen key. 2. Unscrew the electronics compartment cover from the transmitter housing and check the cover seal. 3. Press the release mechanism and remove the display module. 4. Turn the display module to the desired position: maximum 4 × 90 ° in each direction.
Mounting Micropilot FMR60B HART LWARNING Supply voltage switched on! Risk of electric shock and/or explosion! ‣ Switch off the supply voltage before opening the measuring device. 1→ 2→ 3→ 4 mm 1. 2. 2. 2x 1. 0.7 Nm A0046831 A0046832 A0046833 ‣ If fitted: release the screw of ‣ Unscrew the display cover and ‣ Press the release mechanism, 4→ 5→ 6→ the cover lock for the display cover using the Allen key. check the cover seal. remove the display module. 4 mm 2x 1. 0.7 Nm 2.
Micropilot FMR60B HART Mounting 7→ 8 Di sp lay 2. 1. A0048406 ‣ Plug in the connection for the display module in the connection compartment. ‣ Fit the display module in the desired position until it clicks into place. 5.3.8 A0046928 ‣ Screw the display cover firmly back onto the housing. If fitted: tighten the screw of the cover lock using the Allen key 0.7 Nm (0.52 lbf ft). Closing the housing covers NOTICE Thread and housing damaged from dirt! ‣ Remove dirt (e.g.
Electrical connection Micropilot FMR60B HART 6 Electrical connection 6.1 Connecting requirements 6.1.1 Cover with securing screw In the case of devices for use in the hazardous area with a certain type of protection, the cover is sealed by a securing screw. NOTICE If the securing screw is not positioned correctly, the cover cannot provide secure sealing. ‣ Open the cover: slacken the screw of the cover lock with a maximum of 2 turns so that the screw does not fall out.
Micropilot FMR60B HART Electrical connection 6.2 Connecting the device A B 1 C 1 D 1 1 A0046659 A B C D 1 Plastic single compartment housing Aluminum single compartment housing Dual compartment housing Dual compartment housing, L-form Connection compartment cover Housing thread The thread of the electronics and connection compartment is coated with lubricant varnish. Avoid additional lubrication. 6.2.
Electrical connection Micropilot FMR60B HART U 18.5 17.5 16.5 15.5 A 14.5 13.5 12.5 B 11.0 C 10.5 3.6 ILOOP 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 A0047056 A B C Display lighting switched on, Bluetooth can be switched on optionally Display lighting switched off, Bluetooth can be switched on optionally Display lighting switched off and Bluetooth not active 6.2.2 Cable specification Rated cross-section • Supply voltage 0.5 to 2.
Micropilot FMR60B HART Electrical connection 6.2.4 Overvoltage protection The overvoltage protection can optionally be ordered as a "Mounted accessory" via the product structure Devices without optional overvoltage protection Equipment from Endress+Hauser fulfills the requirements of the product standard IEC / DIN EN 61326-1 (Table 2 Industrial Environment).
Electrical connection Micropilot FMR60B HART 6.2.
Micropilot FMR60B HART Electrical connection Dual compartment housing, L-form - + 3 2 1 A0045842 6 1 2 3 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal 6.2.
Electrical connection Micropilot FMR60B HART Devices with M12 plug 4 3 1 2 A0011175 1 2 3 4 Signal + Not assigned Signal – Ground Measuring devices with Harting plug Han7D A B – + 8 + – 7 6 1 2 5 3 4 Han7D + – A0041011 A B + Electrical connection for devices with Harting plug Han7D View of the plug-in connection on the device Brown Green/yellow Blue Material CuZn, gold-plated plug-in jack and plug contacts 6.3 Ensuring the degree of protection 6.3.
Micropilot FMR60B HART Electrical connection NOTICE Plug M12 and plug HAN7D: incorrect mounting can invalidate the IP protection class! ‣ The degree of protection only applies if the connecting cable used is plugged in and screwed tight. ‣ The degree of protection only applies if the connecting cable used is specified according to IP67, NEMA Type 4X. ‣ The IP protection classes are only maintained if the dummy cap is used or the cable is connected. 6.
Operation options Micropilot FMR60B HART 7 Operation options 7.1 Overview of operating options • Operation via operating keys and DIP switches on the electronic insert • Operation via optical operating keys on the device display (optional) • Operation via Bluetooth® wireless technology (with optional device display with Bluetooth) with Smartblue app or FieldXpert, DeviceCare • Operation via operating tool (Endress+Hauser FieldCare/DeviceCare, handheld terminal, AMS, PDM, ...) 7.
Micropilot FMR60B HART Operation options If an incorrect access code is entered, the user obtains the access rights of the Operator role. 7.4 Access to the operating menu via the local display 7.4.1 Device display (optional) Possible to operate the optical operating keys through the cover. No need to open the device.
Operation options Micropilot FMR60B HART 7.4.2 Operation via Bluetooth® wireless technology (optional) Requirement • Device with device display including Bluetooth • Smartphone or tablet with Endress+Hauser SmartBlue app or PC with DeviceCare from version 1.07.05 or FieldXpert SMT70 The range of the connection is up to 25 m (82 ft). The range can vary depending on environmental conditions such as attachments, walls or ceilings.
Micropilot FMR60B HART Operation options 7.6 DeviceCare 7.6.1 Function scope Tool for connecting and configuring Endress+Hauser field devices. The fastest way to configure Endress+Hauser field devices is with the dedicated "DeviceCare" tool. Together with the device type managers (DTMs), DeviceCare presents a convenient, comprehensive solution. For details, see Innovation Brochure IN01047S 7.7 FieldCare 7.7.1 Function scope FDT-based plant asset management tool from Endress+Hauser.
System integration Micropilot FMR60B HART 8 System integration 8.1 Overview of device description files • Manufacturer ID: 17 (0x0011) • Device type ID: 0x11C1 • HART specification: 7.6 • DD files, information and files can be found at: • www.endress.com • www.fieldcommgroup.org 8.
Micropilot FMR60B HART Commissioning 9 Commissioning All configuration tools provide a commissioning assistant that supports the user when setting the most important configuration parameters (Guidance menu Commissioning wizard). 9.1 Preliminaries The measuring range and the unit in which the measured value is transmitted correspond to the data on the nameplate. LWARNING The settings of the current output are relevant for safety! This can result in product overflow.
Commissioning Micropilot FMR60B HART 9.3.2 Via service interface (CDI) 1 2 3 A0039148 1 2 3 Computer with FieldCare/DeviceCare operating tool Commubox FXA291 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface) 9.4 Configuring the device address via software See "HART address" parameter Enter the address to exchange data via the HART protocol. • Guidance → Commissioning → HART address • Application → HART output → Configuration → HART address 9.
Micropilot FMR60B HART Commissioning 9.6 Device configuration 9.6.1 Level measurement in liquids R BD 100% D E F L 0% A0016933 10 R D L E F Configuration parameters for level measurement in liquids Reference point of measurement Distance Level "Empty calibration" parameter (= 0%) "Full calibration" parameter (= 100%) 9.6.
Operation Micropilot FMR60B HART 10 Operation 10.1 Reading off the device locking status Displaying active write protection in the Locking status parameter : • Local display The symbol appears on the main page • Operating tool (FieldCare/DeviceCare) : Navigation: System → Device management → Locking status 10.2 Reading off measured values All the measured values can be read off using the Measured values submenu. Navigation: Application menu → Measured values submenu 10.
Micropilot FMR60B HART Diagnostics and troubleshooting 11 Diagnostics and troubleshooting 11.1 General troubleshooting 11.1.
Diagnostics and troubleshooting Micropilot FMR60B HART Device is not visible in the live list • Possible cause: No Bluetooth connection available Remedial action: Enable Bluetooth in the field device via display or software tool and/or in the smartphone/tablet • Possible cause: Bluetooth signal outside range Remedial action: Reduce distance between field device and smartphone/tablet The connection has a range of up to 25 m (82 ft).
Micropilot FMR60B HART Diagnostics and troubleshooting 1 X 2 A0043759 1 2 Status signal Status symbol with diagnostic event Faults detected by the self-monitoring system of the device are displayed as a diagnostic message in alternation with the measured value display. XXXXXXXXX S S801 XXXXXXXXX 1 2 3 i A0043103 1 2 3 Status signal Status symbol with diagnostic event Event text Status signals F "Failure (F)" option A device error has occurred. The measured value is no longer valid.
Diagnostics and troubleshooting Micropilot FMR60B HART XXXXXXXXX S 1 S801 XXXXXXXXX 2 3 5 6 4 A0038013 1 2 3 4 5 6 Status signal Event text Status symbol Diagnostic event Status signal Event number If two or more diagnostic events occur simultaneously, only the diagnostic message with the highest priority is shown. "Active diagnostics" parameter Key Opens the message about the remedial measures. Key Acknowledge warnings. Key Back to operating menu. 11.
Micropilot FMR60B HART Diagnostics and troubleshooting 11.7 Diagnostic list In the Diagnostic list submenu submenu, up to 5 currently pending diagnostic messages can be displayed. If more than 5 messages are pending, the messages with the highest priority are shown on the display. Navigation path Diagnostics → Diagnostic list Calling up and closing the remedial measures 1. Press . The message for the remedial measures for the selected diagnostic event opens. 2. Press + simultaneously.
Diagnostics and troubleshooting Micropilot FMR60B HART Diagnostic number Short text Remedy instructions Status signal [from the factory] Diagnostic behavior [from the factory] 412 Processing download Download active, please wait C Warning 420 HART Device Configuration Locked Check device locking configuration. S Warning 421 HART Loop Current fixed Check Multi-drop mode or current simulation.
Micropilot FMR60B HART Diagnostics and troubleshooting Diagnostic number 1) Short text Remedy instructions Status signal [from the factory] Diagnostic behavior [from the factory] 942 In safety distance 1. Check level 2. Check safety distance 3. Reset self holding S Warning 1) 952 Foam detected Check process conditions C Warning 1) 968 Level limited 1. Check level 2. Check limit parameters S Warning Diagnostic behavior can be changed. 11.9 Event logbook 11.9.
Diagnostics and troubleshooting Micropilot FMR60B HART • Out of specification (S) • Maintenance required (M) • Information 11.9.
Micropilot FMR60B HART Diagnostics and troubleshooting Reset device parameter For details see the "Description of device parameters" documentation. 11.10.2 Resetting the device via keys on the electronic insert Reset the password 15 s I I I I off on I Display II 2× A0050210 11 Sequence - resetting the password Deleting/resetting the password 1. Press operating key I three times. The Reset Password function is started, the LED flashes. 2. Press operating key I once within 15 s.
Diagnostics and troubleshooting Micropilot FMR60B HART For details see the "Description of device parameters" documentation. 11.12 Firmware history The firmware version can explicitly be ordered via the product structure. This makes it possible to ensure the compatibility of the firmware version with an existing or planned system integration. 11.12.1 Version 01.00.
Micropilot FMR60B HART Maintenance 12 Maintenance No special maintenance work is required. 12.1 Exterior cleaning Notes on cleaning • The cleaning agents used should not corrode the surfaces and the seals • Observe the degree of protection of the device 12.2 Seals The process seals, located on the process connection of the device, should be replaced periodically. The interval between changes depends on the frequency of the cleaning cycles, the cleaning temperature and the medium temperature.
Repair Micropilot FMR60B HART 13 Repair 13.1 General information 13.1.1 Repair concept Endress+Hauser repair concept • The devices have a modular design • Repairs can be carried out by Endress+Hauser Service or by appropriately trained customers • Spare parts are grouped into logical kits with the associated replacement instructions For more information on service and spare parts, please contact your Endress+Hauser sales representative. 13.1.
Micropilot FMR60B HART Repair 13.3.1 HistoROM It is not necessary to perform a new device calibration after replacing the display or transmitter electronics. The spare part is supplied without HistoROM. After removing the transmitter electronics, remove HistoRom and insert it into the new spare part. 13.4 Return The requirements for safe device return can vary depending on the device type and national legislation. 1. Refer to the web page for information: http://www.endress.
Accessories Micropilot FMR60B HART 14 Accessories 14.1 Weather protection cover 316L The weather protection cover can be ordered together with the device via the "Accessory enclosed" product structure. It is used to protect against direct sunlight, precipitation and ice. Weather protection cover 316L is suitable for the dual compartment housing made of aluminum or 316L. The delivery includes the holder for direct mounting on the housing. 228.9 (9.01) 136.4 (5.37) 92.5 (3.64) 135 (5.31) 102.5 (4.
Micropilot FMR60B HART Accessories Material Plastic Order number for accessories: 71438291 14.3 Mounting bracket, adjustable The device can be mounted on a wall or ceiling with the mounting bracket. The device can be aligned with the product surface with the swivel function. The mounting bracket can be ordered together with the device via the product structure "Accessory enclosed". A0048745 15 Ceiling or wall mounting 156 (6.14) 9 (0.35) 3 (0.12) 6 (0.24) 282 (11.1) 230 (9.06) 35 (1.
Accessories Micropilot FMR60B HART Scope of delivery: • 1 × mounting bracket, 316L (1.4404) • 2 × holder, 316L (1.4404) • 6 × screws, A4 • 4 × lock washer, A4 Suitable for device with: • Single compartment housing • Dual compartment housing, L-form and: • Encapsulated antenna, PVDF, 40 mm (1.5 in) • Drip-off antenna 50 mm (2 in), threaded process connection FMR6xB mounting device order number: 71523849 There is no conductive connection between the mounting bracket and the transmitter housing.
Micropilot FMR60B HART Accessories C A D B E A0046692 A B C D E Plastic single compartment housing, remote display Aluminum single compartment housing, remote display Device side, plastic single compartment housing prepared for remote display Device side, aluminum single compartment housing prepared for remote display Device side, dual compartment housing, L-form, prepared for remote display Material of single compartment housing, remote display • Aluminum • Plastic Degree of protection: • IP68 / NE
Accessories Micropilot FMR60B HART Order number: 71063562 For details, see "Technical Information" TI00429F and Operating Instructions BA00371F 14.9 FieldPort SWA50 Intelligent Bluetooth® and/or WirelessHART adapter for all HART field devices For details, see "Technical Information" TI01468S 14.10 Wireless HART adapter SWA70 The WirelessHART adapter is used for the wireless connection of field devices.
Micropilot FMR60B HART Accessories 14.15 Memograph M The Memograph M graphic data manager provides information on all the relevant process variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on an SD card or USB stick. Technical Information TI00133R and Operating Instructions BA00247R 14.
Technical data Micropilot FMR60B HART 15 Technical data 15.1 Input Measured variable The measured variable is the distance between the reference point and the product surface. The level is calculated based on "E", the empty distance entered. Measuring range The measuring range starts at the point where the beam hits the tank floor. Levels below this point cannot be measured, particularly in the case of spherical bases or conical outlets.
Technical data A Micropilot FMR60B HART B H 100% 0% C A0031828 A B C H Antenna tip + 10 mm (0.4 in) Smallest possible measuring range Distance above tank floor = 50 to 80 mm (1.97 to 3.15 in); (water-based medium εr = 2) Vessel height > 0.7 m (2.3 ft) The media groups and the possible measuring range are described as a function of the application and media group in the following section.
Technical data Micropilot FMR60B HART Media groups • A0 (εr 1.2 to 1.4) e.g. n-butane, liquid nitrogen, liquid hydrogen • A (εr 1.4 to 1.9) Non-conductive liquids, e.g. liquefied gas • B (εr 1.9 to 4) Non-conductive liquids, e.g. gasoline, oil, toluene, etc. • C (εr 4 to 10) e.g. concentrated acid, organic solvents, ester, aniline, etc.
Micropilot FMR60B HART Technical data Integrated antenna, PEEK, 40 mm (1.5 in) in storage vessel Media group Measuring range A0 (εr 1.2 to 1.4) 3 m (10 ft) A (εr 1.4 to 1.9) 6 m (20 ft) B (εr 1.9 to 4) 11 m (36 ft) C (εr 4 to 10) 15 m (49 ft) D (εr >10) 22 m (72 ft) Encapsulated antenna, PVDF, 40 mm (1.5 in) in storage vessel Media group Measuring range A0 (εr 1.2 to 1.4) 3 m (10 ft) A (εr 1.4 to 1.9) 6 m (20 ft) B (εr 1.
Technical data Micropilot FMR60B HART Integrated antenna, PEEK, 40 mm (1.5 in) in buffer vessel Media group Measuring range A0 (εr 1.2 to 1.4) 1.5 m (5 ft) A (εr 1.4 to 1.9) 3 m (10 ft) B (εr 1.9 to 4) 6 m (20 ft) C (εr 4 to 10) 13 m (43 ft) D (εr >10) 20 m (66 ft) Encapsulated antenna, PVDF, 40 mm (1.5 in) in buffer vessel Media group Measuring range A0 (εr 1.2 to 1.4) 1.5 m (5 ft) A (εr 1.4 to 1.9) 3 m (10 ft) B (εr 1.
Micropilot FMR60B HART Technical data Integrated antenna, PEEK, 20 mm (0.75 in) in vessel with agitator Media group Measuring range A (εr 1.4 to 1.9) 1 m (3.3 ft) B (εr 1.9 to 4) 1.5 m (5 ft) C (εr 4 to 10) 3 m (10 ft) D (εr >10) 5 m (16 ft) Integrated antenna, PEEK, 40 mm (1.5 in) in vessel with agitator Media group Measuring range A0 (εr 1.2 to 1.4) 1 m (3.3 ft) A (εr 1.4 to 1.9) 1.5 m (5 ft) B (εr 1.
Technical data Micropilot FMR60B HART PTFE Drip-off antenna, 50 mm (2 in) in vessel with agitator Operating frequency Media group Measuring range A0 (εr 1.2 to 1.4) 2 m (7 ft) A (εr 1.4 to 1.9) 4 m (13 ft) B (εr 1.9 to 4) 7 m (23 ft) C (εr 4 to 10) 15 m (49 ft) D (εr >10) 25 m (82 ft) Approx. 80 GHz Up to 8 devices can be installed in a tank without the devices mutually influencing one another. Transmission power • Peak power: 6.3 mW • Average output power: 63 µW 15.
Micropilot FMR60B HART Technical data Operating tool via HART communication Status signal (according to NAMUR Recommendation NE 107): Plain text display Linearization The linearization function of the device allows the conversion of the measured value into any unit of length, weight, flow or volume.
Technical data Micropilot FMR60B HART Device description files (DTM, DD) Information and files under: • www.endress.com On the product page for the device: Documents/Software → Device drivers • www.fieldcommgroup.org HART load: Min.
Micropilot FMR60B HART Technical data Time to establish connection: < 30 s 15.3 Ambient temperature range Environment The following values apply up to a process temperature of +85 °C (+185 °F). At higher process temperatures, the permitted ambient temperature is reduced.
Technical data Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0048826 18 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: 0 to +150 °C (+32 to +302 °F) with CSA C/US approval = = = = = Tp: Tp: Tp: Tp: Tp: 0 °C (+32 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +150 °C (+302 °F) | Ta: +25 °C (+77 °F) +150 °C (+302 °F) | Ta: 0 °C (+32 °F) 0 °C (+32 °F) | Ta: 0 °C (+32 °F) Order option; process temperature range: –20 to +200 °C (–4 to +392 °F) Ta P1 P2 P3 P
Micropilot FMR60B HART Technical data Ta P1 P2 P3 P5 P4 Tp A0032024 21 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +80 °C (–40 to +176 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +80 °C (+176 °F) | Ta: +75 °C (+167 °F) +80 °C (+176 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature r
Technical data Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 23 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +130 °C (–40 to +266 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +130 °C (+266 °F) | Ta: +52 °C (+126 °F) +130 °C (+266 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperatur
Micropilot FMR60B HART Technical data Ta P1 P2 P3 P5 P4 Tp A0032024 25 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +150 °C (–40 to +302 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +150 °C (+302 °F) | Ta: +25 °C (+77 °F) +150 °C (+302 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature
Technical data Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 27 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +200 °C (–40 to +392 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +200 °C (+392 °F) | Ta: +27 °C (+81 °F) +200 °C (+392 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature
Micropilot FMR60B HART Technical data Ta P1 P2 P3 P5 P4 Tp A0032024 30 P1 P2 P3 P4 P5 = = = = = Aluminum housing material; process temperature range: –20 to +200 °C (–4 to +392 °F) Tp: Tp: Tp: Tp: Tp: –20 °C (–4 °F) | Ta: +79 °C (+174 °F) +79 °C (+174 °F) | Ta: +79 °C (+174 °F) +200 °C (+392 °F) | Ta: +47 °C (+117 °F) +200 °C (+392 °F) | Ta: –20 °C (–4 °F) –20 °C (–4 °F) | Ta: –20 °C (–4 °F) Order option; process temperature range: –40 to +80 °C (–40 to +176 °F) Ta P1 P2 P3 P5 P4 Tp A003202
Technical data Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 33 P1 P2 P3 P4 P5 = = = = = Aluminum housing material; process temperature range: –40 to +150 °C (–40 to +302 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +79 °C (+174 °F) +79 °C (+174 °F) | Ta: +79 °C (+174 °F) +150 °C (+302 °F) | Ta: +53 °C (+127 °F) +150 °C (+302 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Order option; process temperature range: –40 to +200 °C (–40 to +392 °F) Ta P1 P2 P3 P5 P4 Tp A
Micropilot FMR60B HART Technical data Ta P1 P2 P3 P5 P4 Tp A0032024 36 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –20 to +200 °C (–4 to +392 °F) Tp: Tp: Tp: Tp: Tp: –20 °C (–4 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +200 °C (+392 °F) | Ta: +38 °C (+100 °F) +200 °C (+392 °F) | Ta: –20 °C (–4 °F) –20 °C (–4 °F) | Ta: –20 °C (–4 °F) Order option; process temperature range: –40 to +80 °C (–40 to +176 °F) Ta P1 P2 P3 P5 P4 Tp A0032024
Technical data Micropilot FMR60B HART Ta P1 P2 P3 P5 P4 Tp A0032024 39 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –40 to +200 °C (–40 to +392 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +200 °C (+392 °F) | Ta: +38 °C (+100 °F) +200 °C (+392 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Storage temperature • Without LCD display: –40 to +90 °C (–40 to +194 °F) • With LCD display: –40 to +
Micropilot FMR60B HART Technical data NOTICE Plug M12 and plug HAN7D: incorrect mounting can invalidate the IP protection class! ‣ The degree of protection only applies if the connecting cable used is plugged in and screwed tight. ‣ The degree of protection only applies if the connecting cable used is specified according to IP67 NEMA Type 4X. ‣ The IP protection classes are only maintained if the dummy cap is used or the cable is connected.
Technical data Micropilot FMR60B HART Process connection UNI flange PP Seal Tp Process pressure range PVDF encapsulated –40 to +80 °C (–40 to +176 °F) –1 to 3 bar (–14.5 to 43.5 psi) The following temperature restriction applies for devices with the dust ignition-proof approval category 1D, 2D or 3D PVDF encapsulated –20 to +80 °C (–4 to +176 °F) –1 to 3 bar (–14.5 to 43.5 psi) A0047947 The pressure range may be further restricted in the event of a CRN approval.
Micropilot FMR60B HART Technical data Integrated antenna, PEEK, 20 mm (0.75 in) Process connection thread 3/4" Seal Tp Process pressure range FKM Viton GLT –40 to +150 °C (–40 to +302 °F) –1 to 20 bar (–14.5 to 290 psi) FKM Viton GLT –40 to +200 °C (–40 to +392 °F) –1 to 20 bar (–14.5 to 290 psi) FFKM Kalrez –20 to +150 °C (–4 to +302 °F) –1 to 20 bar (–14.5 to 290 psi) FFKM Kalrez –20 to +200 °C (–4 to +392 °F) –1 to 20 bar (–14.
Index Micropilot FMR60B HART Index A Access authorization to parameters Read access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Write access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Access code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Incorrect input . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Micropilot FMR60B HART Index Write access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*71575911* 71575911 www.addresses.endress.