unbekannt unbekannt Products Solutions Services Technical Information Micropilot FMR67B HART Free space radar Level measurement in bulk solids Application • • • • • • Continuous, non-contact level measurement of powdered to granular bulk solids Process connections: Flanges with purge air and alignment unit Maximum measuring range: 125 m (410 ft) Temperature: –40 to +450 °C (–40 to +842 °F) Pressure: –1 to +160 bar (–14.5 to +2 321 psi) Accuracy: ±3 mm (±0.
Micropilot FMR67B HART Table of contents Important document information . . . . . . . . . . . . . . . 4 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Function and system design . . . . . . . . . . . . . . . . . . . 5 Mechanical construction . . . . . . . . . . . . . . . . . . . . Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Graphic conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Measuring principle . . . . . . .
Micropilot FMR67B HART RN42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Document function . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 69 Endress+Hauser V. 1, Rev.
Micropilot FMR67B HART Important document information Symbols Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury.
Micropilot FMR67B HART • Installation, explosion and electrical connection drawings are presented in simplified format • Devices, assemblies, components and dimensional drawings are presented in reduced-line format • Dimensional drawings are not to-scale representations; the dimensions indicated are rounded off to 2 decimal places • Unless otherwise described, flanges are presented with sealing surface form EN1091-1, B2; ASME B16.
Micropilot FMR67B HART D = (c ∆t) / 2 where c is the speed of propagation of the wave. In summary, D can be calculated from the measured difference frequency Δf. D is then used to determine the content of the tank or silo. Input Measured variable The measured variable is the distance between the reference point and the product surface. The level is calculated based on "E", the empty distance entered. Measuring range The start of the measuring range is the point where the beam hits the floor.
A Micropilot FMR67B HART B H 100% 0% C A0031829 A B C H Antenna tip + 10 mm (0.4 in) Smallest possible measuring range Distance above silo floor = 50 to 80 mm (1.97 to 3.15 in) Silo height > 0.7 m (2.3 ft) For the dielectric constants (DC values) of many media commonly used in industry, please refer to: • Dielectric constant (DC value) Compendium CP01076F • The Endress+Hauser "DC Values app" (available for Android and iOS) Operating frequency Approx.
Micropilot FMR67B HART Signal on alarm Current output Failure mode (according to NAMUR Recommendation NE 43): • Minimum alarm (= factory setting): 3.
Micropilot FMR67B HART HART specification: 7 DD version: 1 Device description files (DTM, DD) Information and files under: • www.endress.com On the product page for the device: Documents/Software → Device drivers • www.fieldcommgroup.org HART load: Min.
Micropilot FMR67B HART Power supply Terminal assignment Single compartment housing 3 2 - 1 + A0042594 3 1 2 3 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal Dual compartment housing - + 3 2 1 A0042803 4 1 2 3 10 Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal V. 1, Rev.
Micropilot FMR67B HART Dual compartment housing, L-form - + 3 2 1 A0045842 5 1 2 3 Terminals Connection terminals and ground terminal in the connection compartment Positive terminal Negative terminal Internal ground terminal • Supply voltage and internal ground terminal: 0.5 to 2.5 mm2 (20 to 14 AWG) • External ground terminal: 0.5 to 4 mm2 (20 to 12 AWG) In the case of devices with a plug, it is not necessary to open the housing for connection purposes.
Micropilot FMR67B HART Measuring devices with Harting plug Han7D A – B + 8 + – 7 6 1 2 5 3 4 Han7D + – A0041011 A B + Electrical connection for devices with Harting plug Han7D View of the plug-in connection on the device Brown Green/yellow Blue Material CuZn, gold-plated plug-in jack and plug contacts Supply voltage The supply voltage depends on the selected type of device approval Non-hazardous, Ex d, Ex e 10.5 to 35 VDC Ex i 10.
Micropilot FMR67B HART LWARNING Explosion Hazard! ‣ Please refer to the separate documentation on applications in hazardous areas for the safety instructions. For optimum electromagnetic compatibility: • Keep the potential matching line as short as possible • Observe a cross-section of at least 2.
Micropilot FMR67B HART Overvoltage category Overvoltage category II Performance characteristics Reference operating conditions • • • • • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F) Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi) Humidity = 60 % ±15 % Reflector: metal plate with diameter ≥ 1 m (40 in) No major interference reflections inside the signal beam Maximum measured error Reference accuracy The devices are optimized for bulk solid applications on delivery.
Micropilot FMR67B HART • Digital: 1 mm • Analog: 1 µA Response time According to DIN EN IEC 61298-2 / DIN EN IEC 60770-1 , the step response time is the time following an abrupt change in the input signal up until the changed output signal has adopted 90 % of the steady-state value for the first time. The response time can be configured.
Micropilot FMR67B HART Orientation Internal vessel fittings α A0031814 Avoid internal fittings (point level switches, temperature sensors, struts, vacuum rings, heating coils, baffles etc.) inside the signal beam. Pay attention to the beam angle α. Avoiding interference echoes A0031817 16 V. 1, Rev.
Micropilot FMR67B HART Metal deflector plates, installed at an angle to scatter the radar signals, help prevent interference echoes. Vertical alignment of antenna axis Align the antenna so that it is perpendicular to the product surface. The maximum reach of the antenna can be reduced, or additional interference signals can occur, if the antenna is not installed perpendicular to the product.
Micropilot FMR67B HART Information about the mounting nozzle The maximum nozzle length Hmax depends on the nozzle diameter D. H max The maximum nozzle length Hmax depends on the nozzle diameter D D Hmax 80 to 100 mm (3.2 to 4 in) 1 700 mm (67 in) 100 to 150 mm (4 to 6 in) 2 100 mm (83 in) ≥ 150 mm (6 in) 3 200 mm (126 in) øD In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs.
Micropilot FMR67B HART H max Antenna nozzle mounting, flush mount 80 mm (3 in) ØD Hmax 80 to 100 mm (3.2 to 4 in) 1 750 mm (70 in) 100 to 150 mm (4 to 6 in) 2 200 mm (88 in) ≥ 150 mm (6 in) 3 300 mm (132 in) øD In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs. • The edge of the nozzle should be rounded. • Mapping must be performed.
Micropilot FMR67B HART H max The maximum length of the nozzle Hmax depends on the nozzle diameter D D Hmax min. 80 to 100 mm (3 to 4 in) 1 450 mm (57 in) 100 to 150 mm (4 to 6 in) 1 800 mm (71 in) ≥ 150 mm (6 in) 2 700 mm (106 in) øD In the case of longer nozzles, reduced measuring performance must be expected. Please note the following: • The end of the nozzle must be smooth and free from burrs. • The edge of the nozzle should be rounded. • Mapping must be performed.
Micropilot FMR67B HART D α W= 2 . D . tan_ 2 α W A0031824 10 Relationship between beam angle α, distance D and beamwidth diameter W The beamwidth diameter W depends on the beam angle α and the distance D. Horn antenna 65 mm (2.56 in), α 4 ° D W = D × 0.07 α W D W 5 m (16 ft) 0.35 m (1.15 ft) 10 m (33 ft) 0.70 m (2.30 ft) 15 m (49 ft) 1.05 m (3.45 ft) 20 m (66 ft) 1.40 m (4.59 ft) 25 m (82 ft) 1.75 m (5.74 ft) 30 m (98 ft) 2.10 m (6.89 ft) 35 m (115 ft) 2.45 m (8.
Micropilot FMR67B HART PTFE, flush mount 80 mm (3 in) antenna, α 3 ° D W = D × 0.05 α W Special mounting instructions D W 5 m (16 ft) 0.25 m (0.82 ft) 10 m (33 ft) 0.50 m (1.64 ft) 15 m (49 ft) 0.75 m (2.46 ft) 20 m (66 ft) 1.00 m (3.28 ft) 25 m (82 ft) 1.25 m (4.10 ft) 30 m (98 ft) 1.50 m (4.92 ft) 35 m (115 ft) 1.75 m (5.74 ft) 40 m (131 ft) 2.00 m (6.56 ft) 45 m (148 ft) 2.25 m (7.38 ft) 50 m (164 ft) 2.50 m (8.20 ft) 60 m (197 ft) 3.00 m (9.84 ft) 70 m (230 ft) 3.50 m (11.
Micropilot FMR67B HART Container with heat insulation 1 2 A0046566 If process temperatures are high, the device should be included in the usual container insulation system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The rib structure (1) must not be insulated. Environment Ambient temperature range The following values apply up to a process temperature of +85 °C (+185 °F). At higher process temperatures, the permitted ambient temperature is reduced.
Micropilot FMR67B HART Ta P1 P2 P3 Tp P5 P4 A0032024 11 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +80 °C (–40 to +176 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +80 °C (+176 °F) | Ta: +75 °C (+167 °F) +80 °C (+176 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature range of –40 to +8
Micropilot FMR67B HART Ta P1 P2 P3 P5 P4 Tp A0048826 14 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: 0 to +150 °C (+32 to +302 °F) with CSA C/US approval = = = = = Tp: Tp: Tp: Tp: Tp: 0 °C (+32 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +150 °C (+302 °F) | Ta: +25 °C (+77 °F) +150 °C (+302 °F) | Ta: 0 °C (+32 °F) 0 °C (+32 °F) | Ta: 0 °C (+32 °F) Process temperature range: –40 to +200 °C (–40 to +392 °F) Ta P1 P2 P3 Tp P5 P4 A0032024 15 P1 P2
Micropilot FMR67B HART Ta P1 P2 P3 Tp P5 P4 A0032024 17 P1 P2 P3 P4 P5 Plastic housing material; process temperature range: –40 to +280 °C (–40 to +536 °F) = = = = = Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +280 °C (+536 °F) | Ta: +48 °C (+118 °F) +280 °C (+536 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) In the case of devices with plastic housings and CSA C/US approval, the selected process temperature range of –40 to
Micropilot FMR67B HART Process temperature range: 0 to +450 °C (+32 to +842 °F), with CSA C/US approval Ta P1 P2 P3 P5 P4 Tp A0048826 20 P1 P2 P3 P4 P5 = = = = = Plastic housing material; process temperature range: 0 to +450 °C (+32 to +842 °F) with CSA C/US approval Tp: Tp: Tp: Tp: Tp: 0 °C (+32 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +450 °C (+842 °F) | Ta: +20 °C (+68 °F) +450 °C (+842 °F) | Ta: 0 °C (+32 °F) 0 °C (+32 °F) | Ta: 0 °C (+32 °F) Aluminum housing materia
Micropilot FMR67B HART Ta P1 P2 P3 Tp P5 P4 A0032024 23 P1 P2 P3 P4 P5 = = = = = Aluminum housing material; process temperature range: –40 to +200 °C (–40 to +392 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +76 °C (+169 °F) +76 °C (+169 °F) | Ta: +76 °C (+169 °F) +200 °C (+392 °F) | Ta: +47 °C (+117 °F) +200 °C (+392 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Process temperature range: –40 to +280 °C (–40 to +536 °F) Ta P1 P2 P3 Tp P5 P4 A0032024 24 P1 P2 P3 P4 P5 =
Micropilot FMR67B HART Ta P1 P2 P3 Tp P5 P4 A0032024 26 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –40 to +80 °C (–40 to +176 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +80 °C (+176 °F) | Ta: +77 °C (+171 °F) +80 °C (+176 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Order option; process temperature range: –40 to +150 °C (–40 to +302 °F) Ta P1 P2 P3 Tp P5 P4 A0032024 27 P1 P2 P3 P4
Micropilot FMR67B HART Ta P1 P2 P3 Tp P5 P4 A0032024 29 P1 P2 P3 P4 P5 = = = = = 316L housing material; process temperature range: –40 to +280 °C (–40 to +536 °F) Tp: Tp: Tp: Tp: Tp: –40 °C (–40 °F) | Ta: +77 °C (+171 °F) +77 °C (+171 °F) | Ta: +77 °C (+171 °F) +280 °C (+536 °F) | Ta: +54 °C (+129 °F) +280 °C (+536 °F) | Ta: –40 °C (–40 °F) –40 °C (–40 °F) | Ta: –40 °C (–40 °F) Process temperature range: –40 to +450 °C (–40 to +842 °F) Ta P1 P2 P3 Tp P5 P4 A0032024 30 P1 P2 P3 P4 P5 = = =
Micropilot FMR67B HART • Thread NPT1/2, IP66/68 TYPE 4X/6P • HAN7D plug, 90 degrees, IP65 NEMA Type 4X • M12 plug • When housing is closed and connecting cable is plugged in: IP66/67 NEMA Type 4X • When housing is open or connecting cable is not plugged in: IP20, NEMA Type 1 NOTICE Plug M12 and plug HAN7D: incorrect mounting can invalidate the IP protection class! ‣ The degree of protection only applies if the connecting cable used is plugged in and screwed tight.
Micropilot FMR67B HART Horn antenna 65 mm (2.6 in) Process connection standard flange Seal Tp Process pressure range Graphite –40 to +280 °C (–40 to +536 °F) –1 to 160 bar (–14.5 to 2 320.6 psi) Graphite –40 to +450 °C (–40 to +842 °F) –1 to 160 bar (–14.5 to 2 320.6 psi) A0047836 Process connection UNI flange, aluminum adjustable Seal Tp Process pressure range Graphite –40 to +280 °C (–40 to +536 °F) –1 to 1 bar (–14.5 to 14.
Micropilot FMR67B HART Process connection UNI flange, aluminum adjustable with purge air connection Seal Tp Process pressure range FKM Viton GLT –40 to +150 °C (–40 to +302 °F) –1 to 1 bar (–14.5 to 14.5 psi) FKM Viton GLT –40 to +200 °C (–40 to +392 °F) –1 to 1 bar (–14.5 to 14.5 psi) A0047830 The pressure range may be further restricted in the event of a CRN approval. Dielectric constant For bulk solids εr ≥ 1.
Micropilot FMR67B HART Aluminum single compartment housing !101 (3.98) 1 3 124 (4.88) 127 (5) 138 (5.43) 2 45 (1.77) 125 (4.92) ESC - + E A0038380 32 1 2 3 34 Dimensions of aluminum single compartment housing Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window V. 1, Rev.
Micropilot FMR67B HART Dual compartment housing 132 (5.2) 121 (4.76) 115 (4.53) 118 (4.65) 131 (5.16) 127 (5) 2 !101 (3.98) 3 ESC - + E 1 64 (2.52) 54 (2.13) 78 (3.07) 143 (5.63) A0038377 33 1 2 3 Endress+Hauser Dimensions of dual compartment housing Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window V. 1, Rev.
Micropilot FMR67B HART Dual compartment housing, L-form 133 (5.24) 130 (5.12) 110 (4.33) 3 2 144 (5.67) !101 (3.98) !101 (3.98) 1 140 (5.51) 138 (5.43) ESC - + E A0038381 34 1 2 3 Dimensions of dual compartment housing, L-form Height with cover with glass viewing window (devices for Ex d, dust Ex) Height with cover with plastic viewing window Cover without viewing window DN65 horn antenna - flange process connection 1 263 (10.35) L1 R !65 (2.
Micropilot FMR67B HART DN65 horn antenna, with UNI flange and alignment unit 1 263 (10.35) L1 R !65 (2.56) A0048883 36 R 1 L1 Dimensions of DN65 horn antenna, with UNI flange and alignment unit. Unit of measurement mm (in) Reference point of measurement Bottom edge of housing 466 mm (18.35 in); version with Ex d or XP approval +5 mm (+0.20 in) ° (= 3 90 60°) ° 4× 9) .8 (6 90 5 17 ! !23 (0.91) !19 (0.75) !95.2 (3.75) 22 (0.87) 10 (0.
Micropilot FMR67B HART UNI flange UNI 4"/DN100/100A Suitable for ASME B16.5, 4" 150lbs / EN1092-1; DN100 PN16 / JIS B2220; 10K 100A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 1.4 kg (3.09 lb) The number of bolts is reduced in some cases. To match different standards the bores are enlarged. Therefore the bolts should be aligned centrally to the counter flange before tightening. !95.2 (3.75) 22 (0.87) 10 (0.39) UNI flange 6"/DN150/150A for antennas with alignment unit !26 (1.
Micropilot FMR67B HART UNI flange 8"/DN200/200A for antennas with alignment unit 22 (0.87) 10 (0.39) A-A !95.2 (3.75) 15° 30° 30° 15° A 15° 30° 30 ° A !294.5 (11.6) !340 (13.4) !26 (1.02) 15° A0048840 39 Dimensions of UNI flange 8"/DN200/200A for antennas with alignment unit. Unit of measurement mm (in) UNI flange 8"/DN200/200A Suitable for ASME B16.5, 8" 150lbs / EN1092-1; DN200 PN16 / JIS B2220; 10K 200A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 3.2 kg (7.
Micropilot FMR67B HART 22 (0.87) 10 (0.39) UNI flange 10"/DN250/250A for antennas with alignment unit !95.2 (3.75) !26 (1.02) 12 ×3 30 0° (= ° 360° ) !358 (14.1) !405 (15.9) A0048841 40 Dimensions of UNI flange 10"/DN250/250A for antennas with alignment unit. Unit of measurement mm (in) UNI flange 10"/DN250/250A Suitable for ASME B16.5, 10" 150lbs / EN1092-1; DN250 PN16 / JIS B2220; 10K 250A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 4.7 kg (10.
Micropilot FMR67B HART Drip-off antenna, PTFE, 50 mm (2 in), with UNI flange and purge air connection 47 (1.85) L1 L2 1 R !42.5 (1.67) A0046488 41 1 R L1 L2 Dimensions of Drip-off antenna, PTFE, 50 mm (2 in), with UNI flange and purge air connection. Unit of measurement mm (in) Bottom edge of housing Reference point of measurement 175 mm (6.89 in); version with Ex d or XP approval +5 mm (+0.20 in) 108 mm (4.25 in); version with Ex d or XP approval +5 mm (+0.
Micropilot FMR67B HART UNI flange 4"/DN100/100A for Drip-off antenna, PTFE, 50 mm (2 in) with purge air connection 228.6 (9) 190.5 (7.5) 175 (6.9) M80×1.5 19 (0.75) 45° 20 (0.79) A0048876 43 UNI flange 4"/DN100/100A for Drip-off antenna, PTFE, 50 mm (2 in) with purge air connection. Unit of measurement mm (in) UNI flange 4"/DN100/100A Suitable for flange: 4" 150lbs; DN100 PN16; 10K 100A • Material: PP • Process pressure: ≤1 bar (14.5 psi) • Weight: 0.65 kg (1.
Micropilot FMR67B HART Antenna flush mount, PTFE, 80 mm (3 in), with standard flange and purge air connection A B 1 25.5 (1.0) L1 L4 L2 L3 1 R !62.5 (2.46) A0046489 45 A B R 1 L1 L2 L3 L4 Dimensions of antenna flush mount, PTFE, 80 mm (3 in), with standard flange and purge air connection . Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Reference point of measurement Bottom edge of housing 158 mm (6.
Micropilot FMR67B HART Antenna flush mount, PTFE, 80 mm (3 in), with UNI flange and purge air connection A B 1 13.5 (0.53) L1 L4 L2 L3 1 R !50 (1.97) A0046490 46 A B R 1 L1 L2 L3 L4 Dimensions of antenna flush mount, PTFE, 80 mm (3 in), with UNI flange and purge air connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Reference point of measurement Bottom edge of housing 158 mm (6.
Micropilot FMR67B HART UNI flange 8"/DN200/200A Suitable for ASME B16.5, 8" 150lbs / EN1092-1; DN200 PN16 / JIS B2220; 10K 200A • Material 316L • Process pressure: ≤1 bar (14.5 psi) • Weight: 5.1 kg (11.24 lb) 6× 60 ° !29 (1.14) !358 (14.1) !405 (15.9) !80.3 (3.16) UNI flange 10"/DN250/250A for antenna flush mount, PTFE, 80 mm (3 in), purge air connection 8 (0.31) A0048821 48 Dimensions of UNI flange 10"/DN250/250A for DN80 antenna with purge air connection.
Micropilot FMR67B HART Antenna flush mount, 80 mm (3 in), with UNI flange, alignment unit and purge air connection 1 L1 L4 L2 B L3 A 1 !47 (1.85) 11.5 (0.45) R A0046491 49 A B R 1 L1 L2 L3 L4 46 Dimensions of antenna flush mount, 80 mm (3 in), with UNI flange, alignment unit and purge air connection. Unit of measurement mm (in) Process temperature version ≤150 °C (302 °F) Process temperature version ≤200 °C (392 °F) Reference point of measurement Bottom edge of housing 158 mm (6.
Micropilot FMR67B HART ° (= 3 90 60°) ° 4× 9) .8 (6 90 5 17 ! !23 (0.91) !19 (0.75) !95.2 (3.75) 22 (0.87) 10 (0.39) UNI flange UNI 4"/DN100/100A for antennas with alignment unit 45 ° ° 4× 90 90° (=360°) !185 (7.28) !225 (8.86) A0048838 50 Dimensions of UNI flange UNI 4"/DN100/100A for antennas with alignment unit. Unit of measurement mm (in) UNI flange UNI 4"/DN100/100A Suitable for ASME B16.
Micropilot FMR67B HART !95.2 (3.75) 22 (0.87) 10 (0.39) UNI flange 6"/DN150/150A for antennas with alignment unit !26 (1.02) 4×90°(=360°) 90° 45 ° ° 90 ° 90 4× !12 (0.47) (=3 60 °) ! 240 (9.45) !280 (11) A0048839 51 Dimensions of UNI flange 6"/DN150/150A for antennas with alignment unit. Unit of measurement mm (in) UNI flange 6"/DN150/150A Suitable for ASME B16.5, 6" 150lbs / EN1092-1; DN150 PN16 / JIS B2220; 10K 150A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 2.
Micropilot FMR67B HART UNI flange 8"/DN200/200A for antennas with alignment unit 22 (0.87) 10 (0.39) A-A !95.2 (3.75) 15° 30° 30° 15° A 15° 30° 30 ° A !294.5 (11.6) !340 (13.4) !26 (1.02) 15° A0048840 52 Dimensions of UNI flange 8"/DN200/200A for antennas with alignment unit. Unit of measurement mm (in) UNI flange 8"/DN200/200A Suitable for ASME B16.5, 8" 150lbs / EN1092-1; DN200 PN16 / JIS B2220; 10K 200A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 3.2 kg (7.
Micropilot FMR67B HART 22 (0.87) 10 (0.39) UNI flange 10"/DN250/250A for antennas with alignment unit !95.2 (3.75) !26 (1.02) 12 ×3 30 0° (= ° 360° ) !358 (14.1) !405 (15.9) A0048841 53 Dimensions of UNI flange 10"/DN250/250A for antennas with alignment unit. Unit of measurement mm (in) UNI flange 10"/DN250/250A Suitable for ASME B16.5, 10" 150lbs / EN1092-1; DN250 PN16 / JIS B2220; 10K 250A • Material: Aluminum • Process pressure: ≤1 bar (14.5 psi) • Weight: 4.7 kg (10.
Micropilot FMR67B HART Antenna and process connection adapter The flange weight (316/316L) depends on the selected standard and sealing surface. Details -> TI00426F or in the relevant standard The heaviest version is indicated for the antenna weights DN65 horn antenna 4.40 kg (9.70 lb) + flange weight Drip-off antenna 50 mm (2 in) 1.70 kg (3.75 lb) Antenna flush mount, PTFE, 80 mm (3 in) 3.20 kg (7.
Micropilot FMR67B HART Materials in contact with the medium DN65 horn antenna 3 2 1 A0046618 54 1 2 3 Material; DN65 horn antenna. Unit of measurement mm (in) Horn: 316L / 1.4404 Antenna: Al2O3 (ceramic) Antenna seal: graphite Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404 DN65 horn antenna, with UNI flange and alignment unit 3 4 5 6 2 1 A0048884 55 1 2 3 4 5 6 52 Material; DN65 horn antenna, with UNI flange and alignment unit.
Micropilot FMR67B HART Drip-off antenna, purge air connection 4 3 5 6 2 7 1 A0046611 56 1 2 3 4 5 6 7 Material; Drip-off antenna, purge air connection . Unit of measurement mm (in) Antenna: PTFE, seal material FKM Viton GLT Process connection: PP Housing sensor adapter: 316L / 1.4404 Synthetic/organic fiber elastomer seal (asbestos-free), FA material Threaded adapter, plug screw fitting: 316L / 1.
Micropilot FMR67B HART Antenna flush mount, 80 mm (3 in), with UNI flange and purge air connection 3 4 5 2 1 A0046613 58 1 2 3 4 5 Material; antenna flush mount, 80 mm (3 in), with UNI flange and purge air connection. Unit of measurement mm (in) Antenna: PTFE, seal material FKM Viton GLT Process connection: 316L / 1.4404 Housing adapter: 316L / 1.4404 Threaded adapter, plug screw fitting: 316L / 1.
Micropilot FMR67B HART Operability Operating concept Operator-oriented menu structure for user-specific tasks • Guidance • Diagnostics • Application • System Fast and safe commissioning • Interactive wizard with graphical user interface for guided commissioning in FieldCare, DeviceCare or DTM, AMS and PDM-based third-party tools or SmartBlue • Menu guidance with short explanations of the individual parameter functions • Standardized operation at the device and in the operating tools Integrated HistoROM da
Micropilot FMR67B HART Local operation Operating keys and DIP switches on the HART electronic insert off on 1 2 off on Display 4 3 A0046129 60 1 1+2 2 3 4 Operating keys and DIP switches on the HART electronic insert Operating key for reset password (for Bluetooth login and Maintenance user role) Operating keys for device reset (as-delivered state) Operating key II (only for factory reset) DIP switch for alarm current DIP switch for locking and unlocking the device The setting of the DIP swit
Micropilot FMR67B HART System integration HART Version 7 Supported operating tools Smartphone or tablet with Endress+Hauser SmartBlue app, DeviceCare from version 1.07.05, FieldCare, DTM, AMS and PDM HistoROM data management When replacing the electronic insert, the stored data is transferred by reconnecting the HistoROM. The device serial number is saved in the HistoROM. The electronics serial number is saved in the electronics.
Micropilot FMR67B HART If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber of its own), there is no pressure accessory present within the meaning of the Directive. EN 302729 radio standard The devices comply with the LPR (Level Probing Radar) radio standard EN 302729. The devices are approved for unrestricted use inside and outside closed containers in countries of the EU and the EFTA.
Micropilot FMR67B HART EN 302372 radio standard The devices comply with the TLPR (Tanks Level Probing Radar) radio standard EN 302372 and are permitted for use in closed vessels. Points a to f in Annex E of EN 302372 must be observed for the installation. FCC This device complies with Part 15 of the FCC rules.
Micropilot FMR67B HART • NAMUR NE 107 Status categorization in accordance with NE 107 • NAMUR NE 131 Requirements for field devices for standard applications • IEC 61508 Functional safety of safety-related electric/electronic/programmable electronic systems Ordering information Detailed ordering information is available from your nearest sales organization www.addresses.endress.com or in the Product Configurator at www.endress.com: 1. Select the product using the filters and search field. 2.
Micropilot FMR67B HART Measuring range restrictions The following restrictions must be considered when selecting E and F: • Minimum distance between reference point R and 100% mark A ≥ antenna length + 200 mm (8 in) Minimum value: 400 mm (16 in) • Minimum span F ≥ 400 mm (16 in) • Maximum value for Empty calibration E ≤ 50 m (164 ft) • The linearity check is performed under reference operating conditions.
Micropilot FMR67B HART Application packages Heartbeat Technology The Heartbeat Technology application package offers diagnostic functionality through continuous self-monitoring, the transmission of additional measured variables to an external Condition Monitoring system and the in-situ verification of devices in the application. The application package can be ordered together with the device or can be activated subsequently with an activation code.
Micropilot FMR67B HART Areas of application • Measurement in liquids and solids • Reliable detection of buildup on the antenna Detailed description Special Documentation SD02953F Accessories Weather protection cover 316L The weather protection cover can be ordered together with the device via the "Accessory enclosed" product structure. It is used to protect against direct sunlight, precipitation and ice. Weather protection cover 316L is suitable for the dual compartment housing made of aluminum or 316L.
Micropilot FMR67B HART 122 (4.8) !115 (4.53) 140 (5.51) 165 (6.5) 32 (1.26) 140 (5.51) A0038280 63 Dimensions. Unit of measurement mm (in) Material Plastic Order number for accessories: 71438291 Adjustable flange seal The adjustable flange seal is used to align the sensor to the surface of the product. It can be ordered directly with the device via the product structure "Accessory enclosed" or individually via the specific order number.
Micropilot FMR67B HART 33 (1.3) 23.5 (0.93) ø115 (4.53) ø162 (6.38) 14 (0.55) 4° ±8° A0046696 Technical data • • • • • Material: EPDM Recommended screw size: M14 Recommended screw length: 100 mm (3.9 in) Process pressure: –0.1 to 0.1 bar (–1.45 to 1.45 psi) Process temperature:–40 to +80 °C (–40 to +176 °F) Ordering information • The flange seal can be ordered together with the device via the "Accessory enclosed" product structure.
Micropilot FMR67B HART Technical data • • • • • Material: EPDM Recommended screw size: M14 Recommended screw length: 100 mm (3.9 in) Process pressure: –0.1 to 0.1 bar (–1.45 to 1.45 psi) Process temperature:–40 to +80 °C (–40 to +176 °F) Ordering information • The flange seal can be ordered together with the device via the "Accessory enclosed" product structure. • Order number: 71249070 Seal, adjustable, ASME 4" The seal, adjustable, ASME 4" is compatible with flanges ASME 4" 150 lbs 14 (0.55) 33 (1.
Micropilot FMR67B HART Ordering information • The flange seal can be ordered together with the device via the "Accessory enclosed" product structure.
Micropilot FMR67B HART Material of single compartment housing, remote display • Aluminum • Plastic Degree of protection: • IP68 / NEMA 6P • IP66 / NEMA 4x Connecting cable: • Connecting cable (option) up to 30 m (98 ft) • Standard cable provided by customer onsite up to 60 m (196 ft) Ambient temperature: • –40 to +80 °C (–40 to +176 °F) • Option: –50 to +80 °C (–58 to +176 °F) Commubox FXA195 HART For intrinsically safe HART communication with FieldCare via the USB interface For details, see "Technical In
Micropilot FMR67B HART Memograph M The Memograph M graphic data manager provides information on all the relevant process variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on an SD card or USB stick.
Micropilot FMR67B HART Apple® Apple, the Apple logo, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Android® Android, Google Play and the Google Play logo are trademarks of Google Inc. KALREZ®, VITON® Registered trademarks of DuPont Performance Elastomers L.L.C., Wilmington, DE USA 70 V. 1, Rev.
*unbekannt* unbekannt www.addresses.endress.