Intelligent Electronic swing handle – User operations guide PDU Version handle User Operations Guide .
Intelligent Electronic swing handle – User operations guide Key dimensions: MOTOR MODEL ELECTRICAL SPECIFICATION: -POWER 4.5V TO 5V - OPERATON CURRENT: LESS THAN 500mA AT 5V DC WITH NO EXTERNAL MECHANICAL LOAD APPLIED TO HANDLE. - MAX CURENT WITH STALLED ACTUATOR: 1A AT 5V DC. - STANDBY CURRENT: 300mA, TYPICAL.
Intelligent Electronic swing handle – User operations guide FCC COMPLIANCE / TM / WARRANTY FCC ID:2AYS5DRLCKHIDP To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installées doivent être situées de facon à ce que la population ne puisse y être exposée à une distance de moin de 20 cm.
Intelligent Electronic swing handle – User operations guide • Safety Instructions • Please refer to the below instructions before using the Ihandle. Save this manual for future reference. • • • • ■ If cleaning The Ihandle is required. Don’t use liquid or spray detergent; use a moist cloth. ■ Install and operate the Ihandle Preferably, in an air-conditioned environment with temperatures not exceeding 50ºCelsius (122ºFahrenheit).
Intelligent Electronic swing handle – User operations guide Standard supplied Inventory * can be modified to suit specific requirements PDU Version Smart-Handle Kit: The Smart-Handle Kit comprises the following: • • • • • • • • • • • Quantity 1pcs Quantity 1pcs Quantity 1pcs Quantity 1pcs Quantity 2pcs Quantity 5pcs Quantity 1pcs Quantity 1pcs Quantity 1pcs Quantity 1pcs Quantity 2pcs Smart Handle QTY (1) Intelligent swing handle 2m communications cable female rj45 to 4pin JST connector 1.
Intelligent Electronic swing handle – User operations guide Network Cable 2.5m QTY (1) Metal bracket back cover (1) fixing screw (3) Double-sided tape QTY (2) Cable Protect Cover (1) Cable Tie Key QTY (5) QTY (2) Thin Rotation limiter (1) Spring screw (1) Optional extras. Rev.1.
Intelligent Electronic swing handle – User operations guide Door cams Multi latching rod system gearbox Installation: Check the cut-out dimensions. For retrofit, remove the existing rack handles and check the cut-out dimensions (see picture below for typical front door and rear door). Keep the cam from the existing handles (used in Step 4). Note: The Smart-Handle can be retrofitted on racks subject to the door having a cut-out dimensions 125mmx50mm. Rev.1.
Intelligent Electronic swing handle – User operations guide 1. Typical door Typical door 2. Push the Smart-Handle through the cut-out in the door. Rev.1.
Intelligent Electronic swing handle – User operations guide 3. Put the metal back cover on the inside of the handle and insert the 3 screws to secure the handle in place, alternate between the screws while tightening to prevent skewing of the handle. 4. Place the door cam over the handle spindle and then a thick or thin door limiter using the spring screw to secure the mechanism. (For retrofit, re-use the front and rear door cam). Check the cam closes snuggly when the handle is rotated.
Intelligent Electronic swing handle – User operations guide 5. Repeat the procedure for the second door. Network connection: Front Door 1. Connect the Smart-handle Comms Cable 4 pin to RJ45 150mm cable to the iHandle and attach the Blue Network Cable to the RJ45 connector. 2. Connect the RJ45 coupler and Blue Network Extension Cable to the Blue Network Cable. 3. Route and fix the network cable using cable ties and adhesive pads.
Intelligent Electronic swing handle – User operations guide Rear Door 1. The network connection for the rear door is the same as the front door. 2. Ensure the network cable has slack on the hinge side of the door so that it does not get pinched. 3. Connect the RED Network cable to the RJ45 Sensor Port on either the IPDU or sensor POD Door Switch Sensor 1. The Door Switch Sensor consists of two parts: ● 1.2m cable to 5pin connector with Door switch sensor ● Magnet 2.
Intelligent Electronic swing handle – User operations guide 6. The magnet and switch sensor must come into contact when the door is closed for the sensor to determine door closed status. Lock: 1. The Euro profile lock barrel can be replaced with an alternate lock barrel either before or after the handle is installed. 2. Removing the lock retaining screw. 3. Slide the lock cylinder barrel out of the Smart-handle and replace it with the alternate barrel. 4. Re-install the lock retaining screw.
Intelligent Electronic swing handle – User operations guide Rev.1.
Intelligent Electronic swing handle – User operations guide LED light status: LATCH & LED colour STATUS definitions • • • • • • • SECURED SOLID GREEN ELECTRONICALLY RELEASED BLINKING GREEN UNAUTHORISED CARD SWIPE BLINKING MECHANICALLY RELEASED WITH KEY BLINKING RED ELECTRONICALLY LOCKED/SWINGHANDLE OPEN BLINKING DOOR CONTACT OPEN FOR 5 MINUTES BLINKING RED/BLUE ERROR DETECTED SOLID RED Rev.1.
Intelligent Electronic swing handle – User operations guide Operate with PDU: 1.Setup: The Smart-handle can be connected to PDU before or after PDU power up, it usually take 10 to 50 seconds for the Smart-handle detected by PDU, once the Smart-handle detected, the sensor handle, keyed lock and relevant information can be found from PDU’s local display, web GUI or snmp interface.
Intelligent Electronic swing handle – User operations guide Rack Access Control page allows PDU user to perform following configuration: o o o o Authorize an rf id card user Lock/Unlock the handle Change the auto lock time All above configure are under the Action Button as following Authorize rf id card user An ID card user need to be defined given card ID and user name.
Intelligent Electronic swing handle – User operations guide check the event log of the PDU(it takes about 30 seconds for the PDU to pull the latest event from Handle), the log should include item like following: Take the ID from event log, and put into the new user creation pag ( From Action -> New) The username can be in any test – just for memories , select the correct PDU number and Aisle from drop-down selector, click create, the ID card will be authorized to lock/unlock the handle, all authorized car
Intelligent Electronic swing handle – User operations guide Lock/Unlock the handle Lock/Unlock page gives PDU user to performan lock unlock without access the handle with a ID card Rev.1.
Intelligent Electronic swing handle – User operations guide Change the auto lock time The handle come with the auto lock function, if the the lock is open for 3 minutes in default, it will automatically close it. The default auto lock time can be changed in the Change the auto lock time page The auto lock time can be configured between 3-30 minitues. Operate with PoE Handle Please refer to PoE handle user manual Rev.1.
Intelligent Electronic swing handle – User operations guide FAQ: • • • • • • • • • • What if the smart-Handle fails how do I access my IT cabinet? Use the override key provide to manually open the swing handle.