IntegrAlarm USER AND INSTALLER MANUAL (REMOTE SIREN / STROBE UNIT) IntegrAlarm MODEL IA-SRN1 May 16, 2004 Page 1 of 12 Document # E.0015.16.07 443713.
Table of Contents 1 IntegrAlarm Overview..................................................................................... 3 2 Remote Siren/Strobe Unit .............................................................................. 5 2.1 Description ....................................................................................................... 5 2.2 Technical Specifications ................................................................................. 6 3 Installation .................
1 IntegrAlarm Overview The IntegrAlarm wireless security system includes a Control Panel and a number of wireless peripheral units. The system operates on the ISM wireless band of 902-928 MHz, in frequency hopping mode, transmitting short (about 10 ms) packets of data, with each packet transmitted on a different frequency. The system operates on 56 pseudo random selected channels.
FCC Compliance Statement The FCC Wants You to Know This equipment has been tested and found to comply with the limits for a Class B digital unit, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
2 Remote Siren/Strobe Unit 2.1 Description The IntegrAlarm model IA-SRN1 remote siren / strobe unit consists of an RF transceiver, a micro-controller with non-volatile memory, siren generator and amplifier, a piezo element and horn, a high voltage power supply and a discharge tube, a power supply with back-up batteries, and a wall mounted mains isolation transformer, 115 to 12 VAC.
2.2 Technical Specifications Communication principle – two-way. Operating frequency band – ISM 902-928 MHz. Mode of operation – frequency hopping; every packet is transmitted on a different pseudo random selected frequency. Packet transmission duration – less than 10 milliseconds. Packet transmission destination address – destination ID and system ID. Received packet validation check – CRC. Received valid packet acknowledgment – each received valid packet is acknowledged by the addressed destination.
3 Installation Installation of a siren / strobe unit is a five-step procedure. • Step 1: Select and mark the location on the outside wall of the building to be secured, where the siren / strobe unit is to be installed. The siren / strobe unit should be installed in a relatively sheltered spot – for example, under an overhanging roof – in order to protect it from rain, hail, etc. It should be installed high enough to be out of reach without a ladder, to discourage tampering.
4 Enrolling Procedure 4.1 General Note: Assignment of units to protect specific zones should be completed before enrolling procedure may be implemented. See Control Panel Installer Manual, Section 3.2, Installer Function Programming, for instructions. Note: The Installer functions can only be implemented by the system installer. If an ordinary User or Master ID or an incorrect code is entered for any Installer function, an INCORRECT ID prompt will be displayed and an "Incorrect ID" voice prompt will sound.
Press OK at top of Control Panel. An ENTER ID prompt will be displayed and an "Enter ID" voice prompt will sound. Enter your Installer ID. Press the DOWN key repeatedly until the following screen appears: INSTALLER MENU 10: ENROLL ZONES Press OK at top of Control Panel. Screen will show: ENTER ZONE # 1 FRONT DOOR Overwrite the desired number using the numeric keypad and press OK at top of Control Panel.
Prepare unit for Place Test (Section 5 below) as follows: When zone enrollment is complete, secure the unit temporarily to the outside wall of the building to be secured, using an adhesive compound or a double side adhesive tape and proceed to Place Test as described below. Note: For first time installation for this system, Section 4.2 must be repeated for each siren / strobe unit in the system. Page 10 of 12 Document # E.0015.16.07 443713.
5 Place Test From the Enroll Zones menu as shown in Section 4.2 above, press DOWN key at top of Control Panel. Screen will show: INSTALLER MENU 11: PLACE TEST Note: This operation refers to the unit for which Section 4.2 was just performed. Press OK at top of Control Panel. Screen will show: PLEASE ACTIVATE THE ZONE Go to the location where the siren / strobe unit is to be installed, temporarily mount the unit and connect it to mains.
Page 12 of 12 Document # E.0015.16.07 443713.