IntegrAlarm USER AND INSTALLER MANUAL (SMOKE DETECTOR) IntegrAlarm MODEL IA-SMK1 November 2003 Page 8 of 8 pages Document # E0015.16.
Table of Contents 1 IntegrAlarm Overview..................................................................................... 3 2 Smoke Detector............................................................................................... 5 2.1 Description ....................................................................................................... 5 2.2 Technical Specifications ................................................................................. 5 2.3 Installation .........
1 IntegrAlarm Overview The IntegrAlarm wireless security system includes a Control Panel and a number of wireless peripheral units. The system operates on the ISM wireless band of 902-928 MHz, in frequency hopping mode, transmitting short (about 5 ms) packets of data, with each packet transmitted on a different frequency. Time and frequency synchronization is maintained by a synchronization signal transmitted by the system Control Panel to the various peripherals (including the IA SMK-1) every 3 minutes.
FCC Compliance Statement The FCC Wants You to Know This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
2 Smoke Detector 2.1 Description The UL-approved smoke detector sensor unit consists of an RF transceiver, a microcontroller, a photoelectric smoke detector cell with processing ASIC, a test button, a buzzer and two batteries. The sensor unit is composed of the following principal parts: • Mounting plate. • Sensor base. • Sensor PCB with RF controller, terminal block, test button, buzzer and LED. • 9V alkaline battery type 1604. • 3V Lithium HNO2 battery type CR2 • Cover.
Weight (grams): 270. Page 8 of 8 pages Document # E0015.16.
2.3 Installation Installation of each smoke detector is a three-step procedure. The sensor should first be registered via the IntegrAlarm Control Panel. It should then be mounted on the door or window to be secured, and then tested to confirm that it operates properly. 2.3.1 Registration From Installer Menu on Control Panel, select ENROLL. Screen will show: ENTER ZONE # Use numeric keypad at right of Control Panel to enter the desired zone number. The description of the zone number (e.g.
Before mounting the smoke detector, it is necessary to ensure that all of the components listed in Section 2.1 above are present and in good order. Disassemble the sensor assembly and perform a visual inspection. Write down the serial number from sensor base on a piece of paper for use in the registration process as set forth in Section 2.3.2 below. Now, using two screws, attach the mounting plate to the ceiling in the marked location as shown in Figure 1 below.