Owner's manual

BLU-CP Pulpit Control
BLU-CP Wiring Instructions
IMPORTANT: CAT5 wiring for the RJ-45 connector needs to be
crimped to TIA/EIA 568B Standards (see below) on both ends of the cable.
You must crimp and test the wiring with an approved CAT5 568A/B
tester before connecting any cable between the BLU-CP and either a
BLU-CIF or BLU-IF Interface unit. Failure to crimp wiring to the correct
standard could possibly lead to component damage.
CAUTION: If the BLU-CP is being installed in a remodel, check the
width of the opening in the pedestal for proper clearance of the ribbon cable.
You should not crimp or crush the ribbon cable during the install. If the
opening in the pedestal is too narrow, you can either chisel out more
clearance or mount the BLU-CP up using the enclosed nylon standoffs.
The BLU-CP is a pulpit control module for BSS
Audio London Series Digital Signal
Processors. It is built on a 2.5” X 6” aluminum
plate with a Mylar overlay on the front side of
the plate containing the integrated switches and
status LED’s. The switches on the top of the
BLU-CP adjust the height of the pulpit. The
middle switches adjust the volume in the
Chapel, and between these switches are five
LED’s that provide a visual indication of the
volume level. The bottom switch turns the
sound system on and off, and it has an LED
associated with it for indicating when the sound
system is on. On the backside of the BLU-CP is
a single RJ-45 Cat5e connector for connecting
the module to the DSP, and a 3-pin Euro-block
for connecting to the pulpit motor.