FCC Part 24 Transmitter Certification Test Report FCC ID: DNY0B2SCELL1900 FCC Rule Part: CFR 47 Part 24 Subpart E ACS Report Number: 05-0272-24E Manufacturer: EMS Wireless Equipment Type: PCS Band Bi-Directional Amplifier Model: SelectaCell-19-S Operators Manual 5015 B.U.
® SelectaCell -19S OPERATOR’S MANUAL (Preliminary) 1900 MHz BAND-SELECT INDOOR REPEATER 2850 Colonnades Court Norcross, GA 30071 U. S. A. Tel: +770.582.0555 Fax: +770.729.0075 IM609873-1 Rev.
Handling the SelectaCell® 1. Use ESD precautions when dealing with the modules within the SelectaCell™ so that units are not damaged. 2. Opening the unit voids warranty. 3. Disconnecting any component within the SelectaCell™ when powered can damage or destroy the equipment and will void the warranty. 1.0 Description The SelectaCell® repeater, is a PCS band, band selective bi-directional amplifier with integrated donor and server antennas.
SelectaCellTM Operator’s Manual – Preliminary 4.0 EMS Wireless Primary Power The SelectaCell® operates on 7.5 VDC input power @ 0.7 Amp. This unit is supplied with a regulated wall mount power supply, which is UL, and CSA listed and will operate on AC input voltage of 90-240 VAC. 5.0 Donor/Server Antenna Internal donor and server antennas have 13 dB and 10dB gain, respectively.
SelectaCellTM Operator’s Manual – Preliminary 7.0 EMS Wireless Introduction SelectaCell® setup is automated for easy installation. This section will provide the basic steps to performing the unit’s setup and installation. SelectaCell® is designed to automatically optimize set up and will improve performance in most applications as long as a signal can be received at a window. Actual area of coverage that will be improved will vary depending on the signal level received and blockage.
SelectaCellTM Operator’s Manual – Preliminary 8.0 EMS Wireless Setup Instructions There are two setup methods that may be used to select and set a 5 or 15 MHz frequency band on SelectaCell™; a. Manual Push Button b. Computer setup through the USB ports Setup Instructions using the Manual Push Button SelectaCell-19S must be set up to the proper assigned frequency band before completing installation.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless 5. Once the desired band is selected, hold down the button for 3 seconds, this will now program the unit for the selected band and enter the unit into downlink monitor mode. 6. In downlink monitor mode only the downlink signal is being amplified. The LCD display will have bars on the left side indicating downlink signal and bars on the right side indicating downlink gain.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless · install the.........."Setup.exe" (double click) · Follow the set up procedure displayed 4. Connect a USB type “A” Male to “A” Male cable into computer USB port and the SelectaCell® Note: The SelectaCell® AC power should not be plugged in at this time. a. A pop-up window should appear on the computer screen advising that new USB hardware is present and the driver is being installed. b.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless Frequency setting changes are password protected and by pressing Ctrl-Alt-p enter password as all caps " PASSWORD" a. Select the “By Band” method of Frequency Selection i. Select the appropriate PCS band or sub-band with a mouse click. (Single alpha letter of entire band or alpha numeric segments). ii.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless Screen Shots Interface Overview Using the USB Connection The preliminary version of the SelectaCell® application has 3 menu tabs that can be selected from the top portion of the application. Screenshots and explanations of the menus are as follows: Identity Startup Screen Screen A Identity screen displays SelectaCell® unit version, Model, Serial and PCB Serial Number plus any error status indicators.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless Frequency Screen Screen B Indicates frequency / PCS band of operation and also displays error indicators. Select the frequency tab and select the appropriate PCS band or sub-band with a mouse click. Activate the “Set” button with a mouse click to setup either by the desired band in the SelectaCell® or input the center frequency for the downlink and the uplink will automatically display .
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless Control Screen Screen C Displays downlink and uplink output power and gain and is used to restart the SelectaCell® after selecting a new frequency band. After selecting the PCS band, in the previous frequency screen, activate “Restart” button with a mouse click initiate automated setup.
SelectaCellTM Operator’s Manual – Preliminary 9.0 EMS Wireless Specifications Downlink Operating Frequency, Uplink Operating Frequency, Downlink Transmit Power, Uplink Transmit Power, System Gain, Gain Flatness Noise Figure Spurious Output @ Rated Power, FCC Regulations, Spurious Emissions Operating Temperature Power AC to DC External MTBF Automatic System Set Up Certifications Meets or exceeds the EIA/TIA requirements for CDMA, TDMA or GSM system protocols.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless These products are covered by the following warranties: 1. General Warranty EMS Wireless warrants to the original purchaser all standard products sold by EMS Wireless to be free of defects in material and workmanship for the duration of the warranty period of one (1) year from date of shipment from EMS Wireless.
SelectaCellTM Operator’s Manual – Preliminary c. 3. EMS Wireless Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment.
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless SelectaCell®-19S Manual Confidential and Proprietary Information IM609873-1 Rev 01 07/11/05 EMS Wireless 17
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless SelectaCell®-19S Manual Confidential and Proprietary Information IM609873-1 Rev 01 07/11/05 EMS Wireless 18
SelectaCellTM Operator’s Manual – Preliminary EMS Wireless 2850 Colonnades Court Norcross, GA 30071 PH: 770.582.0555 FAX: 770.729.