Type Acceptance Test Report Multimode PCS Repeater FCC Rule Parts: 2, 15 & 24 ACS Report Number: 03-0089-24TA Manufacturer: EMS Wireless Model: Link2Cell Installation Guide 5015 B.U.
Link2Cell™-19 SOHO Signal Enhancer Small Office – Home Office SIGNAL ENHANCER OPERATOR’S MANUAL 2850 Colonnades Court NW Norcross, GA 30071 Phone: 770-582-0555 Fax: 770-729-0075 Email: www.emswireless.
Preliminary Document Confidential EMS Wireless Disclaimer Every attempt has been made to make this material complete, accurate, and up-to-date. Users are cautioned, however, that EMS Wireless reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors.
Preliminary Document Confidential EMS Wireless WARNINGS, CAUTIONS, AND GENERAL NOTES This product conforms to FCC Part 15. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Preliminary Document Confidential EMS Wireless Safety Considerations When installing or using this product, observe all safety precautions during handling and operation. Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product. EMS Wireless assumes no liability for the customer's failure to comply with these precautions.
Preliminary Document Confidential EMS Wireless Service Do not attempt to modify or service any part of this product other than in accordance with procedures outlined in this Operator's Manual. If the product does not meet its warranted specifications, or if a problem is encountered that requires service, notify EMS Wireless’ sales department. Service will be rendered according the EMS Wireless’ warranty and repair policy.
Preliminary Document Confidential EMS Wireless a. Return authorization shall be received from the EMS Wireless Customer Service prior to returning any device. Advise the EMS Wireless Customer Service of the model, serial number, and the discrepancy. The device shall then be forwarded to EMS Wireless, transportation prepaid. Devices returned freight collect or without authorization may not be accepted. b.
Preliminary Document Confidential EMS Wireless Handling the Link2Cell™ -19 1. Use ESD precautions when dealing with the modules within the Link2Cell™ -19 so that units are not damaged. 2. Opening the unit voids warranty. 3. Disconnecting any component within the Link2Cell™-19 when powered can damage or destroy the equipment and will void the warranty.
Preliminary Document Confidential EMS Wireless Link2Cell™-19 Manual Description The Link2Cell™-19 SOHO, (Small Office-Home Office) Signal Enhancer, is a PCS band, bidirectional amplifier unit and was designed to provide enhanced RF coverage for wireless systems in small facilities. Usage includes providing coverage in retail stores, offices, warehouses, restaurants, homes, etc. The Link2Cell™-19 is housed in an indoor mountable enclosure, and is powered with a regulated wall mountable power supply.
Preliminary Document Confidential EMS Wireless Red indicator. User can try recycling the power which will allow the unit to go thru its automatic set up operation but if the problem persists contact your service provider.
Preliminary Document Confidential EMS Wireless Primary Power The Link2Cell™ Unit operates on 9 VDC input power @ 1 Amp. This is supplied with a regulated wall mount supply, which is UL, and CSA listed. These are available to operate on AC input voltage of 115 VAC. Donor/Server Antenna Internal donor and server antenna are each 13 dB nominal gain. The donor antenna must be orientated to point in the direction of the Service Providers cell site location.
Preliminary Document Confidential EMS Wireless Installation: Note 1: The user is cautioned that modification or changes to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Note 2: Manufacturer’s rated composite output power, individual channel power will vary depending on the number of channels and distance from each cell site being received Note 3: This device complies with Part 15 of the FCC Rules.
Preliminary Document Confidential EMS Wireless Getting Started: Unpack all of the boxes and insure all of the material is included for your installation requirements and undamaged in shipment.
Preliminary Document Confidential EMS Wireless Link2Cell™-19 Unit Orientation & Installation Link2Cell™ is designed for optimum use as an in-door signal enhancer. The housing is not weather resistant and the automatic set up procedure assumes sufficient isolation between antennas. Since the Link2Cell™ has a total of 53 dB active gain and an isolation of 73 dB must be obtained between the internal donor and the server antenna.
Preliminary Document Confidential EMS Wireless -Select the window that provides the strongest signal strength from the cell site to your portable phone by viewing the number of bars displayed on the face of the phone.
Preliminary Document Confidential EMS Wireless -Attach Mounting Base (with the open U potion in an upward ? position) to the selected position mounting surface area using the appropriate mounting hardware, (4 Wall anchors and 4 mounting screws). Slide Link2Cell Unit into Mounting Base Attach Mounting Base to Mounting Surface Using Appropriate Mounting Hardware -In a downward ? sliding motion, hook the Link2Cell™ Unit onto the secured mounting base.
Preliminary Document Confidential EMS Wireless IMPORTANT: Before performing any maintenance or changing the position or location of the unit, make sure power plug is removed from the 110 AC wall socket. Once the unit is repositioned, the power should be plugged into the 110 wall socket, this will insure the unit is set to maximum gain and performance. System Set Up Instructions: -After installing unit, apply power and Link2Cell™ unit will automatically set up.
Preliminary Document Confidential EMS Wireless Trouble Shooting: The Link2Cell™-19 has no field replaceable parts; repair is limited to improper mounting location with respect to the cell site, insufficient RF signal levels, and installation or defective units.