FCC Part 22 Transmitter Certification Test Report FCC ID: DNY0A1EKOMINI8 FCC Rule Part: CFR 47 Part 22 Subpart H ACS Report Number: 05-0373-22H Manufacturer: EMS Wireless Equipment Type: Cellular Bi-Directional Amplifier Model: EKOMINI-8 Operator’s Manual 5015 B.U.
TM EkoMini BAND SELECTIVE INDOOR REPEATER OPERATOR’S MANUAL 2850 Colonnades Court Norcross, GA 30071 U. S. A. Tel: +770.582.0555 Fax: +770.729.
EMS Wireless Disclaimer Every attempt has been made to make this material complete, accurate, and up-todate. Users are cautioned, however, that EMS Wireless reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors.
EMS Wireless WARNINGS, CAUTIONS, AND GENERAL NOTES This product conforms to FCC Part 15. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
EMS Wireless Service Do not attempt to modify or service any part of this product other than in accordance with procedures outlined in this Operator's Manual. If the product does not meet its warranted specifications, or if a problem is encountered that requires service, notify EMS Wireless’ customer support department. Service will be rendered according the EMS Wireless’ warranty and repair policy.
EMS Wireless 2. Specific Product Warranty Instructions All EMS Wireless products are manufactured to high quality standards and are warranted against defects in workmanship, materials and construction, and to no further extent. Any claim for repair or replacement of a device found to be defective on incoming inspection by a customer must be made within 30 days of receipt of the shipment, or within 30 days of discovery of a defect within the warranty period.
EMS Wireless 3.
EMS Wireless EkoMini™ Manual Description The EkoMini is a band selective, bi-directional amplifier unit and was designed to provide enhanced RF coverage for wireless systems in small facilities. Usage includes providing coverage in retail stores, offices, warehouses, restaurants, homes, etc. The EkoMini is housed in an indoor mountable enclosure, and is powered with a regulated wall mountable power supply.
EMS Wireless The EkoMini has 30 dB of gain control in the uplink and downlink signal paths. This gain is controlled by two methods. Up to 14 dB can be controlled by adjusting the user peak limit switches located behind an access plate on the side of the unit to limit the maximum output power level. The uplink and downlink attenuators are controlled by the internal microprocessor to adjust the maximum gain of the unit for both paths.
EMS Wireless Uplink Gain Offset, reduces uplink gain Gain Offset (dBm) 0 -2 -4 -6 One off on off on Two off off on on If a unit is initially set-up or moved from one location to another, pressing and holding the reset switch a minimum of 5 seconds until the LED’s blink will restart the automatic set up feature.
EMS Wireless Protocol Selection To insure proper RF power output the proper protocol must be selected this insures the software will properly distinguish the detected RF power level. CDMA is the only protocol that requires a different look up table/RF calibration. Protocol Selection Switch Five CDMA All Other* On Off *All other protocols include; AMPS, GSM, PCS 1900, IDEN, ESMR, TDMA Band Selection EkoMini 1.9 PCS Band, is available in two models.
EMS Wireless EkoMini Cellular Band switches 3 and 4 are used to EkoMinimize the gain of the adjacent bands control channels by increasing the frequency roll off in band. It should be noted that the two switches shift the center frequency of the band; they do not change the bandwidth of the filter. The operation band is preset by the factory and not customer changeable.
EMS Wireless A factory default password is preprogrammed into the unit as 11111. The user may change this in the program mode of operation. There is also a factory access password. Up to three numbers and alarm codes or paging pin numbers can be sent. The unit will send an alarm to the first number when an alarm occurs. (The alarm is not sent during the red flashing alert period. It is delayed 5 minutes to be certain the alarm will not clear itself).
EMS Wireless or factory personnel may also review them. Retrieving log history requires entering the password. Command, Clear Log File, is accessible only with the factory password. Alarms All alarms are considered major since there are no field replaceable modules in the unit. All alarms are indicated locally and immediately by the Alarm LED indicator blinking red. Once the Alarm State has existed for 5 minutes, the Alarm LED will have a constant red indication.
EMS Wireless The EkoMini can be programmed requiring a Keep Alive activation from as often as the user desires, but at least once daily. The factory default requires one daily activation and is set to occur between 3:00 and 4:00 AM.
EMS Wireless detectable level. A quick check can be made by getting within a few feet of the Rerad Antenna, while watching the Uplink RF indicator. Primary Power The EkoMini Unit operates on 9 VDC input power @ 6 Amps. This is supplied with a regulated wall mount supply, which is UL and CSA listed. These are available to operate on AC input voltages of 90 to 260 VAC. Donor Antenna This input/output is connected to an antenna, which is directed at the desired cell site.
EMS Wireless Introduction EkoMini is quick and easy to install, using a minimum set of common tools. This section will provide the basic steps to performing the installation of EkoMini. Please read complete instructions before beginning assembly. Getting Started: Unpack all of the boxes and insure all of the material is included for your installation requirements and undamaged in shipment.
EMS Wireless Select mounting location of Rerad antenna to provide maximum coverage while maintaining at least a 20-foot spacing from closest cell phone usage if possible to reduce the possibility of overdrive. IMPORTANT: Before performing channel or amplitude adjustments on any unit, make sure power is OFF. System Set Up Instructions: -During initial set-up, downlink signal must be presented to the unit. -Apply Power after setting user switches and unit will automatically set up.
EMS Wireless Setting up your EkoMini: For the EkoMini to Report Alarms, the unit must be first connected to a telephone line. To activate the unit to remotely report alarms, the unit must be contacted by modem via a computer, the setup procedure completed and the unit issued the Activate Report Alarms Command: (set rp actv = yes). If any of these steps are skipped the unit will not function properly. STEP 1. Contacting the EkoMini. This can be achieved by using ANY Hyper Terminal Program. A.
EMS Wireless STEP 2. Setting up the EkoMini. A. Set the Report 1 Dial out Telephone Number. RP 1 DIAL (Dial out Number. 20 digits) B. Set The Pin Number (if Applicable). RP 1 PINN (Pin Number. 10 digits, maximum) C. Set Report 2 Dial out Telephone Number. RP 2 DIAL (Dial out Number. 20 digits) D. Set The Pin Number (if Applicable). RP 2 PINN (Pin Number. 10 digits, maximum) E. Set Delay for dialing out Telephone Number 2 after 1. RP 2 DLAY (Dial Delay in minutes from Telephone Number 1, 0-999) F.
EMS Wireless STEP 3. Testing the Reporting. A. Testing the remote alarming. test report 1 Note: Before logging off the unit, it is advisable to test the configuration. By issuing a test report 1 command, the unit will log the user off and try to send an alarm code to the Report 1. If there are no alarms, it will send a 0. Keep Alive Functionality Theory of Operation: The EkoMini's Keep Alive can be set up to function in one of various formats.
EMS Wireless Commands: MENU = Displays List of Commands HELP = Displays List of Commands And Help Formatting EVNT = Displays User Alarm Log CONF = Displays Basic Configuration RPRT = Displays Report Alarms Settings KPAL = Displays KeepAlive settings TEST REPORT # = Will log off user and attempt to page report # with alarm cleared code. Enter KADIAL to test the Keep Alive Number. Example (TEST REPORT KADIAL) SET: KTIME = Keep Alive time, Answer and Dial. xx:xx (24 hr.
EMS Wireless Important Notes: The EkoMini has a factory default auto answer set for 2 rings. Factory Default Settings: KTIME = 03:30 (24 hr.
EMS Wireless EMS Wireless EkoMini Manual 23
EMS Wireless Trouble Shooting: The EkoMini has no field replaceable parts; repair limited to correcting improper set-up or customer software programming, installation issues or defective units.
EMS Wireless Specifications: Frequency-Models EkoMini 1.9-15, Band A EkoMini 1.9-15, Band B EkoMini 1.9-15 Band C EkoMini 1.9-5, Band D EkoMini 1.9-5 Band E EkoMini 1.
EMS Wireless Specifications: Frequency-Models EkoMini 8-14CB, Cellular B EkoMini 8-2.5CBE, Cellular BE EkoMini 8-11CA, Cellular A EkoMini 8-1.
EMS Wireless 2850 Colonnades Court Norcross, GA 30071 U. S. A. Tel: +770.582.0555 Fax: +770.729.0075 900-0801-A17 Rev.