eNfusion™ HSD-Xi High-speed Data Terminal System Description, Installation, and Maintenance Manual MN-1252-42003, Revision B00 This document provides procedures for the equipment listed below.
PROPRIETARY STATEMENT This document contains information which is proprietary and confidential to EMS SATCOM (EMS Technologies Canada, Ltd.). Neither this document nor the information contained within may be used for any purpose other than the purpose for which it was prepared. Neither this document nor the information contained within may be disclosed or copied without the prior written permission of EMS SATCOM. © 2007, 2008, 2009 EMS Technologies Canada, Ltd. All Rights Reserved.
CUSTOMER RESPONSE FORM To help us improve the quality of our product documentation, EMS SATCOM would appreciate your comments and suggestions on this publication. Please complete the following customer survey and send to EMS SATCOM at: EMS SATCOM 400 Maple Grove Road Ottawa, ON, K2V 1B8 E-mail: techdocs@emssatcom.
Blank Page 23-15-30 CR-2 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal RECORD OF REVISIONS When revisions are received, insert revised pages, record the date, and initial.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 RR-2 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal SERVICE BULLETIN LIST Service Bulletin Number Subject 23-15-30 Manual Rev. Manual Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 SBL-2 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal LIST OF EFFECTIVE PAGES * An asterisk indicates pages changed, added, or deleted by the current revision. F indicates a right foldout page with a blank back.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 LEP-2 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal TABLE OF CONTENTS INTRODUCTION 1. General ........................................................................................................... INTRO-1 2. How This document is Organized ................................................................ INTRO-1 3. Illustration of Equipment .............................................................................. INTRO-2 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal C. Front Panel LEDs ............................................................................................................ 1-7 D. Fault Conditions............................................................................................................... 1-8 E. HSD-Xi Maintenance Port............................................................................................... 1-8 8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 5. Installing the HSD-Xi and ESCM............................................................................ 3-5 A. Hardware and Software Requirements............................................................................ 3-5 B. User Interfaces ................................................................................................................ 3-5 C. Creating Connections ..........
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal D. Repair Facility Approvals ................................................................................................. 5-8 E. Return for Repair Information .......................................................................................... 5-9 (1) Warranty Returns ........................................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal LIST OF FIGURES Figure INTRO-1 HSD-Xi Terminal ..................................................................................... INTRO-2 Figure 1-1 Simplified Aeronautical Satellite Communications System ....................................... 1-2 Figure 3-1 HSD-Xi System Transmit (TX) Loss .......................................................................... 3-2 Figure 3-2 System RX Loss .
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 TC-6 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal LIST OF TABLES Table 1-1 HSD-Xi Characteristics and Specifications............................................................... 1-5 Table 1-2 HSD-Xi Terminal Environmental Characteristics ....................................................... 1-5 Table 1-3 Discrete Outputs ........................................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 TC-8 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal INTRODUCTION 1. General This manual provides the specifications, principles of operation, and information necessary to install an eNfusion™ HSD-Xi terminal, and the eNfusion™ External Subscriber Configuration Module (ESCM). 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 3. Illustration of Equipment Figure INTRO-1 HSD-Xi Terminal 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 6. Acronyms and Abbreviations The following acronyms and abbreviations are used in this document.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal LAN Local Area Network LES Land Earth Station LRU Line Replaceable Unit Mbps Megabit per second MCDU Multipurpose Control Display Unit MCU Modular Concept Unit MES Mobile Earth Station MPDS Mobile Packet Data Services MPU Maintenance Port Utility ms Millisecond MSN Mobile Serial Number MSN Multiple Subscriber Number O&I Outline and Installation Diagram OA Other Antenna OR
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 7. Safety Advisories Warnings, cautions, and notes in this manual provide the reader with the following information: • A WARNING describes an operation, procedure, or condition that, if not obeyed, could cause injury or death. • A CAUTION describes an operation, procedure, or condition that, if not obeyed, could cause damage to the equipment.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal CAUTION: THIS EQUIPMENT INCLUDES ITEMS THAT ARE ELECTROSTATIC DISCHARGE SENSITIVE (ESDS) DEVICES. ESDS DEVICES ARE SUBJECT TO DAMAGE BY EXCESSIVE LEVELS OF VOLTAGE AND/OR CURRENT. THE LOW-ENERGY SOURCE THAT MOST COMMONLY DESTROYS ESDS DEVICES IS THE HUMAN BODY, WHICH, IN CONJUNCTION WITH NONCONDUCTIVE GARMENTS AND FLOOR COVERINGS, GENERATES AND RETAINS STATIC ELECTRICITY.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal SYSTEM DESCRIPTION This section includes basic information about the HSD-Xi terminal, and includes the following sections: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 1-1 Simplified Aeronautical Satellite Communications System Satellite communication systems provide users with long-range voice and data communication by accessing global satellite and ground communications networks. Inmarsat is an international organization that operates and maintains multiple geostationary satellites and satellite networks.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 2. Equipment Overview This section briefly describes the HSD-Xi terminal, the ESCM and the SwiftBroadband (SBB) services supported by the HSD-Xi terminal. A. HSD-Xi The HSD-Xi terminal cannot communicate with the satellite network on its own. It extends the communication functions provided by HSD-440 terminals.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal (b) Standard IP Standard IP services, also known as Background IP services, can transfer data at a rate of up to 432 Kbps. Typical throughput rates range between 100 to 300 kbps. This bandwidth is shared by all users on a channel, and users may experience lower transfer rates when multiple users are transferring data.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table 1-1 lists the physical characteristics and equipment specifications for the HSD-Xi terminal. Table 1-1 HSD-Xi Characteristics and Specifications Characteristic Specification Physical Characteristics Size 2 MCU ARINC 600-10 Form Factor Weight 8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table 1-2 HSD-Xi Terminal Environmental Characteristics (Continued) Characteristic 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-7 to Figure 3-10 present the HSD-Xi and network mode HSD terminals connection details. 6. Electrical Description See Figure 3-7 to Figure 3-10 for installation information. 7. HSD-Xi Terminal System Interfaces This section briefly describes the external HSD-Xi terminal system interfaces connections to other systems on the aircraft.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table 1-4 Front Panel LEDs LED Description (when illuminated) LED Color Top Green MP10 A Power - This output is illuminated if the unit has power. It flashes if the HSD-Xi has an active call. Middle Red MP10C HSD-Xi Fail - This output is illuminated if the HSD-Xi has a fault.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table 1-5 HSD-Xi Maintenance Port Pin Description 8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal • A standard VT100 compatible terminal or computer running an emulator program such as HyperTerminal©, ProComm (PCPLUS)©, or another serial communication package provides the user interface to the HSD-Xi terminals MPU.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal SYSTEM OPERATION This section describes how to register and activate the HSD-X and HSD-Xi terminals. For information on how to configure the system, see Configuring the system. 1. Registering and Activating Terminals Registering and activating an HSD-X and HSD-Xi terminal includes the following: • Preparing Terminal Information • Choosing Service Providers • Registering Terminals A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal • 3.1 kHz audio • 56 kbps data • 64 kbps UDI • MPDS B. Choosing Service Providers Contact Inmarsat for an up-to-date list of Inmarsat Service Providers using the following contact information: Inmarsat 99 City Road, London EC1Y 1AX Tel: +44 20 7728 1000 Fax: +44 20 728 1044 Customer Care Tel: +44 20 7728 1777 Fax: +44 20 7728 1142 Email: customer_care@inmarsat.com Web addresses: www.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal INSTALLATION This section describes how to install HSD-Xi on an network mode HSD terminal. It includes the following sections: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal You need the following hardware to install the HSD-Xi terminal: 4. • size 1 ARINC 600 connector • size 1 coax contacts (on HSD-440 tray)—installation specific • size 5 coax contacts—installation specific Electrical Installation A. Cabling Notes The system transmit loss between the network mode HSD terminal and the HSD-Xi terminal should be as close as possible to 29.5 dB.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-2 illustrates the network mode system RX loss. Figure 3-2 System RX Loss After you have installed the HSD-Xi, measure the cable loss. You must configure the HSD terminal with the measured value. B. Source/Destination Identification (SDI) Source/Destination Identification (SDI) is provided for the beam steering unit and the high-power amplifier (HPA) according to ARINC 741 specifications.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-3 HSD-Xi Remote Status LED Driver Circuits E. System Mode Strapping To install the HSD-440 terminal in network mode, strap these pins as follows: • TP-4A—Strapped • TP-4B—Strapped • TP-4C—Strapped • TP-4D—Open NOTE: Pins marked 0 are signaled by strapping to ICAO Common (TP7K). Pins marked 1 are signaled by an open circuit—no connection.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal F. HSD-Xi Input/Output Strapping Table 3-1 provides the Input/Output (I/O) strapping for the HSD-Xi.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal C. Creating Connections For information on creating SBB connections, see "Setting Up SBB" on page F-1, or the eNfusion™ HSD High-speed Data Terminal Developer’s Guide, MN-1252-13005. 6. Configuring the system After installing the HSD-Xi, you must configure the HSD to operate in network mode, and set the HSD-Xi cable loss.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 3. To access the classic AERO service parameter, type 83. A prompt to enable or disable the classic channel card appears. 4. Press 1 to enable the classic channel card. 5. Press 0 to disable the classic channel card. 6. To activate the new parameter setting, reboot the network mode HSD terminal.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-8 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-4. HSD-Xi Outline Diagram, 1252-E-4124 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-10 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-5. HSD-Xi Outline Diagram, 1252-E-4124 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-12 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-6. ESCM Outline Diagram, 1252-E-4123 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-14 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-7. System Interconnection Diagram HSD-440 Network Mode (HSD-Xi), 1252-B-4303 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-16 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-8. System Interconnection Diagram HSD-440 Network Mode (HSD-Xi), 1252-B-4303 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-18 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-9. System Interconnection Diagram HSD-440 Network Mode (HSD-Xi), 1252-B-4303 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-20 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure 3-10. System Interconnection Diagram HSD-440 Network Mode (HSD-Xi), 1252-B-4303 Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 3-22 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal TEST AND FAULT ISOLATION This section provides the information required to determine the operational readiness of the HSD-Xi terminal, and to aid service personnel in diagnosing system faults.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 5. To access the HSD-Xi parameter, type 48. A prompt to define the HSD-Xi as installed or not installed appears. 6. To activate the connection between the network mode HSD terminal and the HSD-Xi terminal, press 1. 7. Power cycle both units. The network mode HSD terminal can now communicate with the HSD-Xi terminal. To verify the HSD-Xi installation: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 2. Adjustment and Alignment Procedures There are no adjustment or alignment procedures required for HSD-Xi terminals. 3. Modification History The HSD-Xi terminal currently has no history of modifications.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 4-4 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal MAINTENANCE AND REPAIR This section provides maintenance and repair information for the HSD-X and HSD-Xi terminal. It includes the following sections: 1. • Maintenance • Repair Maintenance The HSD-X and HSD-Xi terminals do not require routine maintenance.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal B. Connecting to the HSD-Xi terminal through the network mode HSD Console Mode Use the procedures in this section to verify the operation of the HSD-Xi terminal. These procedures use the console mode of the network mode HSD terminal maintenance port utility.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 7. Type the appropriate filename for the software being loaded to the HSD-Xi Channel Card (for example appl41.hex or cfig41.hex), and then press ENTER. The application prompts you to select a COM port. 8. Type the appropriate COM port (1 or 2—typically 1), and then press ENTER. 9. To start the load, press ENTER. Communication with the HSD-Xi transceiver is established.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Load new software with a laptop or computer connected to the maintenance port of the HSD-Xi terminal, using the EMS Loader application. Load new software with a laptop or computer connected to the maintenance port of the HSD terminal, using the EMS Loader application.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal • Swift64-PR-9140-x.x.x-rfcontrol.hex, ENTER, N, ENTER NOTE: Do not load Swift64-PR-9140-x.xx-rfcontrol2.hex. 14. To terminate the list, press ENTER at the prompt. Communication with the HSD-Xi terminal is established. A percentage (%) load status indicator appears on the screen.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 7. In the HSD Load folder, double-click ADT_LOAD.exe to launch the load application. The EMS Loader opens in a DOS window, displays the Load Target menu, and prompts you to select a target for the software. 8. To load control processor software to the control processor, press 0 (zero), and then press ENTER. The load application prompts you to type a filename. 9.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 8. To load application software, type 24. 9. Press ENTER. The system prompts you for a filename. NOTE: The filename follows the format li_XX.bin. 10. Type the filename of the software. 11. Press ENTER. The program prompts you to select a COM port. 12. Type the COM port connected to the HSD-Xi terminal, and then press ENTER. 13. To start the load, press ENTER.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 7. Verify that all software has loaded successfully to both channel cards. Verify that the firmware versions shown match the versions listed on the load disk (or files) and in the software service bulletin (examples shown above). 8. Close the terminal emulation program. 9. Remove power from the HSD-Xi terminal. This completes the software load verification.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal E. Return for Repair Information To return equipment to EMS SATCOM for repair, follow the Return Materials Authorization procedure. Failure to comply with this procedure may cause shipping delays and additional charges. (1) Warranty Returns Equipment that qualifies for warranty repair can be returned to EMS SATCOM for repair or replacement at our discretion.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 400 Maple Grove Road Ottawa, Ontario Canada K2V 1B8 RMA#__________ Attn: Repair & Overhaul 6. Fax or email the details of the shipment to the R&O Coordinator, including the following information: Shipment date, carrier name and the waybill number. NOTE: The processing of LRU returns is limited to standard business hours from 8:30 am to 5:00 pm EST.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Approval for return to service must be entered in the logbook as required by section 43.9 of the FAR. • The following scheduled maintenance tasks must be added to the aircraft operator's appropriate aircraft maintenance program: • Recommended periodic scheduled servicing tasks: None required. • Recommended periodic inspections: None required.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 5-12 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX A: INMARSAT SATELLITE BEAM COVERAGE Inmarsat operates strategically placed geostationary satellites called I-3 and I-4. I-3 satellites provide access to services such as Swift64 and Aero H/H+, and I-4 satellites provide access to SBB services. Each I-3 satellite is located over and named after an OR.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure A-2 Inmarsat I3 Satellite Beam Coverage—Composite Map 23-15-30 A-2 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure A-3 Inmarsat I-3 Satellite Beam Coverage—OR Maps At the time of publishing, three I-4 satellites provide SBB services: Americas (98W), EMEA (25E) and Asia-Pacific (143.5E). Figure A-4 shows the area covered by I-4 satellites.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure A-4 I-4 Satellite Coverage Map 23-15-30 A-4 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX B: TROUBLESHOOTING CHECKLIST Before performing the detailed testing and troubleshooting procedures provided in this manual, read the following Troubleshooting Checklist. Use the Troubleshooting Checklist to make sure that you have not missed any key steps in the HSD-X and HSD-Xi terminal setup. 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal • Verify that all external user and networking devices (for example: TAs, routers, fax, telephones, computers) are connected and configured properly. 5. Have any changes to the system been made? For previously installed and functional terminals, make note of any changes made to the system since the last time the terminal functioned without problems.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX C: INSTALLATION PLANNING CHECKLIST Installation Planning Steps 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Installation Planning Steps Fwd ID System mode Data I/O (if applicable) SDI 3. Wiring Antenna Multi-Control BITE A/B HPA Mute A/B Power ISDN: Wire the ISDN line. Channels 1 and 2 operate over ISDN 1. ISDN-1 Ethernet: Ethernet-1 Wire the Ethernet port for SBB.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX D: INSTALLATION CHECKLIST Aircraft Identification: Network Mode HSD Terminal Model No.: HSD Terminal Install. Mode: Network Mode HSD Terminal Serial No.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Section Parameter Config.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal HSD-Xi terminal Heading (Deg) Antenna Selected Antenna Azimuth CH 1 Signal 15 30 45 60 75 90 105 Operational Test 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 360 23-15-30 D-3 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 D-4 8 MAY 09
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX E: INMARSAT CAUSE CODES Table E-1 defines the maintenance port menu fault codes of the HSD-X and HSD-Xi terminal.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 1661 Call failed, long interruption in reception at LES 1662 LES long term blockage of SCPC MES 1790 Call cleared, failure credit card validation process 1791 Call cleared, failure authentication process 1811 NCS MES ID busy 1812 NCS MES ID busy IPDS 1841 Call cleared, NCS initiated preemption fo
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 2051 Call failed, dialed number is barred 2052 Call failed, LES selected is barred 2053 Call failed, number dialed must be in a phonebook 2053 Call failed, terminal can only be used with a valid SIM 2055 Call failed, user not logged in 2056 Call failed, user not logged in to SIM 2057 Call failed,
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8000 ACSE Recycling 8001 ACSE Top Of Find BB 8002 ACSE Top Of Process BB 8010 ACSE Finding Primary NCS Long 8011 ACSE Finding Secondary NCS Short 8012 ACSE Finding Primary Standalone Short 8013 ACSE Finding Primary NCS Short 8014 ACSE Finding Primary Standalone Long 8018 ACSE Finding Secondar
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8306 ACSE failed retry ORR 8310 ACSE ORR Query Begin 8311 ACSE ORR Query Burst 8312 ACSE ORR Query Successful 8313 ACSE ORR Query Failed 8400 ACSE Fixed Begin 8401 ACSE Fixed MESRP 8402 ACSE Fixed Call Type Set 8410 ACSE Fixed Tune NCSA 8411 ACSE Fixed Channel Assignment 8420 ACSE Fixed C
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8900 ACSE Logoff Begin 8901 ACSE Successful Logoff 8902 ACSE No ORR Logoff 9000 ACSE accepts call 9003 ACSE accepted 9004 ACSE rejected 9020 ACSE call waiting 9021 ACSE idle selective clear 9022 ACSE TDM not found 9080 ACSE rejected fixed call due to invalid NSR 9081 ACSE In MRSi 9082 A
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 9126 Peripheral bonding none 9130 Peripheral STU enabled 9131 Peripheral STU disabled 9200 MSG T_AM received 9201 MSG A_AM received 9202 MSG T_HA received 9203 MMI normal 9204 MMI inert 9205 MMI programming 9206 MMI reboot 9207 MMI powerdown 9208 MMI accepted 9209 MMI rejected 400000
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 400901 CT SP ODU status no alarms 400902 CT SP ODU status DDS 400910 CT SP prod test 400911 CT SP prod test ODU 401000 CT SP clear spot beam 800103 Mobile AMBE 800124 Mobile aero 64k speech 800404 Mobile data 800504 Mobile facsimile 800606 Mobile 64k UDI 800607 Mobile 56k UDI 800610 Mob
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 12C7 Call cleared, MES missing SCPC channel release SU sup service 12C8 Handover failed, LES not detected 12D1 Call failed, Spot-beam data invalid 12D2 Call failed, invalid scrambling vector 15A1 Call failed, MES not authorized at this LES 15A2 Call failed, service not authorized at this LES 15A3
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 18E2 NCS MES busy already MPDS 1F01 Call cleared by terrestrial circuit (normal call termination from ground source) 1F11 Call failed, terrestrial party busy 1F21 Call failed, LES time-out (no answer) 1F61 Call failed, terrestrial circuit failure (call attempted during ORR) 1F62 Call failed, early
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B021 MOD Su overflow B022 MOD Su not transmitted B024 MOD invalid frame no B025 MOD invalid slot no B028 MOD cannot Tx Su while tuning B030 MOD channel out of range B032 MOD cannot tune while Tx B033 MOD tuning in progress B040 MOD error watchdog B100 DEMOD error, general B101 DEMOD error
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Table E-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B323 ODU error alarm over voltage B324 ODU error alarm reverse power B328 ODU failed due to tx power check B329 ODU error alarm timeout B330 ODU error alarm timeout no trip B400 Internal temperature of terminal too high, turn off for 10 minutes B401 Internal temperature sensor failed B410 Mod e
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal APPENDIX F: SETTING UP SBB This appendix describes how to set up a single client on a packet-switched SBB connection. 1. Requirements To configure and use a background standard IP connection, you must connect a computer to the Ethernet port of the HSD-X and HSD-Xi terminal. If you are connecting a computer or router to the Ethernet port of the HSD-Xi terminal, use a RJ-45 cross-over cable.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal 3. Click Create a new connection. The New Connection Wizard appears, as shown in Figure F-2. Figure F-2 New Connection Wizard 4. Click Next. The Network Connection Type page appears, as shown in Figure F-3. Figure F-3 Network Connection Type Page 5. Click Connect to the Internet, and then click Next. The Getting Ready page appears, as shown in Figure F-4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure F-4 Getting Ready Page 6. Click Set up my connection manually, and then click Next. The Internet Connection page appears, as shown in Figure F-5. Figure F-5 Internet Connection Page 7. Click Connect using a broadband connection that requires a user name and password, and then click Next. The Connection Name page appears, as shown in Figure F-6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure F-6 Connection Name Page 8. In the ISP Name box, type BGAN, and then click Next. The name you type is the name that appears in the list of connections available on your computer. The Connection Availability page appears, as shown in Figure F-7. Figure F-7 Connection Availability Page 9. Click Anyone's use or My use only, and then click Next.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure F-8 Internet Account Information Page 10. In the User name box, type a user name that you will remember. 11. In the Password box, type a password that you will remember. 12. In the Confirm password box, retype your password. 13. Click Next. The Completing the New Connection Wizard page appears, as shown in Figure F-9. Figure F-9 Completing the New Connection Wizard Page 14.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Figure F-10 Connect Dialog Box 15. Click Properties. The Properties dialog box appears, as shown in Figure F-11. Figure F-11 Properties Dialog Box 16. In the Service Name box, type the service string SBB:BACKGROUND@USER=username@PASS=password@APN=my .apn.com.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal • SBB:BACKGROUND@APN=my.apn.com for Background IP service that uses specific access point name • SBB:BACKGROUND@USER=username@PASS=password for Background IP service that uses a specific username and password. Replace “username”, “password”, and “my.apn.com” with your username, password, and APN IP address. This defines the primary PDP context as a background SBB connection.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal Blank Page 23-15-30 F-8 8 MAY 09