eNfusion® HSD-440 Mark 2 Terminal System Description, Installation, and Maintenance Manual MN-1252-33412, Revision 001 This document provides procedures for the equipment listed below.
PROPRIETARY STATEMENT This document contains information which is proprietary and confidential to EMS Aviation (EMS Technologies Canada, Ltd., Formation Inc., Sky Connect LLC). Neither this document nor the information contained within may be used for any purpose other than the purpose for which it was prepared. Neither this document nor the information contained within may be disclosed or copied without the prior written permission of EMS Aviation. © 2010 EMS Technologies Canada, Ltd., Formation Inc.
CUSTOMER RESPONSE FORM To help us improve the quality of our product documentation, EMS Aviation would appreciate your comments and suggestions on this publication. Please complete the following customer survey and send to EMS Aviation at: EMS Aviation 400 Maple Grove Road Ottawa, ON K2C 0P9 E-mail: techdocs@emsaviation.
Blank Page 23-15-30 CR-2 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal RECORD OF REVISIONS When revisions are received, insert revised pages, record the date, and initial.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 RR-2 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal SERVICE BULLETIN LIST Service Bulletin Number N/A Subject N/A Manual Rev. Manual Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 SBL-2 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal LIST OF EFFECTIVE PAGES * An asterisk indicates pages changed, added, or deleted by the current revision. F indicates a right foldout page with a blank back.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 LEP-2 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal TABLE OF CONTENTS 1. Illustration of Equipment .............................................................................INTRO-2 2. Product Terms and Conditions ...................................................................INTRO-2 3. Acronyms and Abbreviations......................................................................INTRO-2 4. Safety Advisories .....................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 6. Software Description .......................................................................................... 1-19 A. Software Specifications .................................................................................................. 1-19 B. Operational Software Part Numbers .............................................................................. 1-19 C. Owner Requirements Table (ORT) ..............
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (4) Keyboard.................................................................................................................... 2-12 (5) Special Symbols......................................................................................................... 2-12 (6) Navigating the MCDU ................................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (10) Hookswitch Strapping .............................................................................................. 3-11 (11) Priority 4 Call Strapping............................................................................................ 3-11 (12) Cockpit Voice Strapping........................................................................................... 3-12 (13) User Interfaces.....................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 2. Troubleshooting and Fault Isolation ................................................................. 4-74 A. Troubleshooting Practices ............................................................................................. 4-74 (1) Non-specific Complaints ............................................................................................ 4-74 (2) Specific Complaints.................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal F. Configuring CEPT-E1 Parameters .................................................................................... 6-7 (1) Configuring CEPT-E1 Interface.................................................................................... 6-8 (2) Configuring the CEPT-E1 Interface Type..................................................................... 6-8 G. Configuring High Speed Data Services ...................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal L. Configuring Antenna ORT Parameters .......................................................................... 6-20 (1) Configuring the Antenna Type ................................................................................... 6-20 (2) Configuring the Antenna Mounting Rotation Angle .................................................... 6-21 (3) Configuring the Antenna Mounting Pitch Angle .....................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (6) Configuring PIMBIT HGA Elevation Offset Angle2 .................................................... 6-31 (7) Configuring PIMBIT Measurement Discard Ratio ...................................................... 6-31 (8) Configuring PIMBIT Failure Threshold....................................................................... 6-32 (9) Configuring PIMBIT Pointing Failure Threshold....................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal D. Understanding the Solo Word ........................................................................................F-10 E. Understanding Start of Transmission (SOT) .................................................................. F-11 F. Understanding End of Transmission (EOT) ....................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 TC-10 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal LIST OF FIGURES Figure INTRO-1 HSD-440 Mark 2 Terminal........................................................................INTRO-2 Figure 1-1 Simplified Aeronautical Satellite Communications System ........................................ 1-2 Figure 1-2 HSD-440 Mark 2 Terminal SCM.................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 4-12 Menu 30 Screen Display ........................................................................................ 4-53 Figure 4-13 HSD-440 Mark 2 Terminal MPU Reports .............................................................. 4-56 Figure 4-14 Example Report 23 Output .....................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal LIST OF TABLES Table 1-1 HSD-440 Mark 2 Terminal Characteristics and Specifications ................................... 1-5 Table 1-2 HSD-440 Mark 2 Terminal RTCA/DO-160E Environmental Characteristics .............. 1-8 Table 1-3 Inertial Type Labels .................................................................................................. 1-12 Table 1-4 GNSS Type Labels ......................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-5 Terminal Connection Settings .................................................................................. 4-39 Table 4-6 Menu 1 Item Descriptions ......................................................................................... 4-41 Table 4-7 Menu 2 Item Descriptions .........................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal INTRODUCTION This manual provides the specifications, principles of operation, and information necessary to install the: • HSD-440 Mark 2 Terminal, 1252-A-3820-01 This document is divided into the following sections: • System Description • System Operation • Installation • Test and Fault Isolation • Maintenance and Repair • Configuring the Owners Requirements Table (ORT) • Appendix A: Inmarsat Satellit
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 1. Illustration of Equipment Figure INTRO-1 shows the HSD-440 Mark 2 Terminal. Figure INTRO-1 HSD-440 Mark 2 Terminal 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Americas Americas (satellite) AMO Approved Maintenance Organization AOR-E Atlantic Ocean Region-East AOR-W Atlantic Ocean Region-West APAC Asia-Pacific (satellite) ATC Air Traffic Control AWG American Wire Gauge BGAN Broadband Global Area Network BITE Built-In Test Equipment BOP Bit Oriented Protocol bps Bits per second BRI Basic Rate ISDN BSU Beam Steering Unit (also known as ACU or Driver)
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal I/O Input/Output ICAO International Civil Aviation Organization ICD Interconnection Drawing IMEI International Mobile Equipment Identifier IMSI International Mobile Subscriber Identifier IMN Inmarsat Mobile Number INS Inertial Navigational System IOR Indian Ocean Region IRS Inertial Reference System ISDN Integrated Services Digital Network ISN Inmarsat Serial Number ISP Inmarsat Service Provide
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal ORT Owner Requirements Table PAST Person Activated Self Test PC Personal Computer (or laptop) PIM Passive Intermodulation PN Part Number POR Pacific Ocean Region POST Power On Self Test POTS Plain Old Telephone System PPP Point-to-Point Protocol PPPoE Point-to-Point Protocol over Ethernet PSTN Public Switch Telephone Network PTT Push-to-Talk RAM Random Access Memory REA Responsible Engineer
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal WSC Williamsburg SDU Controller WSCI Williamsburg SDU Controller Interface 4. Safety Advisories Warnings, cautions, and notes in this manual provide the reader with the following information: • A WARNING describes an operation, procedure, or condition that, if not obeyed, could cause injury or death.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal CAUTION: THIS EQUIPMENT INCLUDES ITEMS THAT ARE ELECTROSTATIC DISCHARGE SENSITIVE (ESDS) DEVICES. ESDS DEVICES ARE SUBJECT TO DAMAGE BY EXCESSIVE LEVELS OF VOLTAGE AND/OR CURRENT. THE LOW-ENERGY SOURCE THAT MOST COMMONLY DESTROYS ESDS DEVICES IS THE HUMAN BODY, WHICH, IN CONJUNCTION WITH NONCONDUCTIVE GARMENTS AND FLOOR COVERINGS, GENERATES AND RETAINS STATIC ELECTRICITY.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 INTRO-8 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal SYSTEM DESCRIPTION This section includes basic information about HSD-440 Mark 2 Terminals, and includes the following sections: • Inmarsat System Overview • Equipment Overview • Equipment Specifications • System Interfaces • User Interfaces • Software Description 1. Inmarsat System Overview This section provides an overview of the Inmarsat satellite communications system and networks.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 1-1 Simplified Aeronautical Satellite Communications System Satellite communication systems provide users with long-range voice and data communication by accessing global satellite and ground communications networks. Inmarsat is an international organization that operates and maintains multiple geostationary satellites and satellite networks.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Inmarsat’s I-4 satellites provide SwiftBroadband (SBB) services and Aero H+ services. The three I-4 satellites are: • Americas • EMEA (Europe, Middle East and Africa) • Asia-Pacific The HSD-440 Mark 2 Terminal, in conjunction with an ARINC 741/781 High-gain Antenna (HGA), acts as an MES/AES.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • Cockpit communications for air-to-ground calls using the MCDU, or the WSC • CEPT-E1 • SwiftBroadband (SBB) packet-switched and circuit-switched services The HSD-440 Mark 2 Terminal contains a SCM that has four SIM card slots. Each slot (and each SIM card) is associated with a specific channel.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • • POTS supports: • In Swift 64 mode, one or two channels of ISDN (speech) or 3.1kHz audio (fax) • In SBB mode, one channel AMBE+2 voice or 3.1kHz audio (fax) CEPT-E1 is offered through the Aero-H+ service and offers 1 or 2 channels of voice NOTE: Only one service type can be used at one time on aHSD-440 Mark 2 Terminal channel.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-1 HSD-440 Mark 2 Terminal Characteristics and Specifications (Continued) Characteristic Power consumption Specification Maximum: 460 W NOTE: Of this power consumption, 400 W is dissipated internally and 60 W of RF power is dissipated externally. Frequency Power Factor Minimum: 360 Hz Typical: 400 Hz Maximum: 800 Hz Leading: >0.77 Lagging: >0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-1 HSD-440 Mark 2 Terminal Characteristics and Specifications (Continued) Characteristic Antenna gain (HGA) Specification Minimum: 12 dB Maximum: 17 dB Antenna to DLNA loss Maximum: 0.3 dB DLNA gain Minimum: 53 dB Maximum: 60 dB DLNA noise Maximum: 1.8 dB DLNA to HSD-440 Mark 2 Terminal total loss Minimum: 6 dB Maximum: 25 dB (Rx) Minimum: 1 dB Maximum: 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-2 lists the RTCA/DO-160E environmental characteristics for HSD-440 Mark 2 Terminals. Table 1-2 HSD-440 Mark 2 Terminal RTCA/DO-160E Environmental Characteristics Section Environmental Condition Category/Comment 4 Temperature and Altitude 4.5.1 Ground Survival Low F2 4.5.1 Short Time Operating Low F2 4.5.2 Operating Low Temperature F2 4.5.3 Ground Survival High Temperature F2 4.5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-2 HSD-440 Mark 2 Terminal RTCA/DO-160E Environmental Characteristics Section Environmental Condition Category/Comment 16.5.1.6 Normal Frequency Variation, 360 Hz to A(WF) 800 Hz 16.5.1.7 DC Content A(WF) 16.5.1.8 Voltage Distortion A(WF) 16.5.2.1 Abnormal Operating Condition A(WF) 16.5.2.2 Abnormal Frequency and Voltage Condition A(WF) 16.5.2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 4. System Interfaces This section briefly describes the external HSD-440 Mark 2 Terminal system interfaces required to control, monitor, maintain, and supplement the terminal. "Installation" on page 3-1 provides a detailed description of interface connections. Figure 1-3 shows the system interfaces of the HSD-440 Stand-Alone terminal. Figure 1-3 HSD-440Stand-Alone Terminal Interfaces A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal For more information about using the CMC, refer to the CMC manufacturer’s documentation. B. Source Destination Identification (SDI) The SDI is strapped to indicate the installation type. C. FWD IDs, ICAO IDs, and IMSI The HSD-440 Mark 2 Terminal uses two 24-bit IDs called Forward/Return Link Pairs (FRLPs) for the Swift 64 service: a Forward ID (FWD ID) and a Return ID (RTN ID).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal E. IRS ARINC 429 Interface The HSD-440 Mark 2 Terminal supports two IRS inputs and three types of labels: • Inertial • GNSS • Hybrid Table 1-3, Table 1-4, and Table 1-5 list the labels for both primary and secondary IRS inputs. NOTE: The HSD-440 Mark 2 Terminal does not process the equipment ID label.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-5 Hybrid Type Labels Label Type Latitude Priority Name Label 1 HYBRID_LATITUDE 254 2 GNSS_LATITUDE 110 1 HYBRID_LONGITUDE 255 2 GNSS_LONGITUDE 111 1 HYBRID_GROUND_SPEED 175 2 GNSS_GROUND_SPEED 112 1 HYBRID_TRUE_TRAK 137 2 GNSS_TRUE_TRAK 103 1 HYBRID_HEADING_132 132 2 AIRCRAFT_HEADING 314 Pitch angle N/A AIRCRAFT_PITCH 324 Roll angle N/A AIRCRAFT_ROLL 325 Altitude 1
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 1-6 AES ID Type Labels Name F. Label ICAO Part 1 275 ICAO Part 2 276 Antenna Interface The HSD-440 Mark 2 terminal interfaces to any mechanically-steered, conformal-array, or phased-array antenna subsystems that are compatible with ARINC 741 and 781.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The HSD-440 Mark 2 Terminal supports three MCDUs. B. WSC The WSC is a device that uses an ARINC 429 interface per ARINC 741 Part 2 Attachment 2F-42.1, which provides display functions similar to the MCDU. For more information about the WSC, see the WSC manufacturer’s documentation and ARINC 741 Part 2 Attachment 2F-42.1. C.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 1-4 HSD-440 Mark 2 Terminal ISDN Connections You can install RJ45 interface connectors in the cabin area to facilitate connection to the ISDN interface. Refer to "Installation" on page 3-1 for a description of the RJ45 connector and cable termination. E. Ethernet Data Interfaces HSD-440 Mark 2 Terminals provide two Ethernet data interfaces.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal G. CEPT-E1 Interface The CEPT-E1 interface provides access to a maximum of two calls through Aero H+ voice services. The CEPT-E1 interface connects to standard ITU or ARINC 746-compliant equipment. Users can select the equipment through an ORT parameter. H.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal "Test and Fault Isolation" on page 4-35 provides a detailed description of the two levels of user access and the menus, report selections, functions, and system diagnostic procedures of the HSD-440 Mark 2 Terminal MPU. I. Fault Indicator LED Table 1-7 provides a description of the fault indicator LED functions.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • VP RAM • VP Application Code CRC • VP Kernel • VP 4-Wire or POTS COM • VP 4-Wire #1 • VP 4-wire #2 J. Self-Test The self-test button activates the HSD-440 Mark 2 Terminal self-test. The self-test button resets the HSD-440 Mark 2 Terminal. The HSD-440 Mark 2 Terminal performs a POST when the self-test button is pressed for over ten seconds. K.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal C. Owner Requirements Table (ORT) The HSD-440 Mark 2 Terminal includes an ORT that stores information relevant to the operation of the terminal. The ORT is divided into two parts: secure and user. The secured partition contains those items that are installation-dependent and crucial to the proper operation of the satellite communication system. End users cannot modify these parameters.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal SYSTEM OPERATION This section provides basic information on registering and operating HSD-440 Mark 2 Terminals, including the following sections: • Registering and Activating Terminals • Configuring Terminals • Using Terminals 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The Swift 64 terminal type for all modes of HSD-440 Mark 2 Terminals is 76HW07. Currently, supported service types for HSD-440 Mark 2 Terminals operating Swift 64 are: • 64 kbps speech • 3.1 kHz audio • 56 kbps data • 64 kbps UDI • AMBE voice • MPDS B. Obtaining ICAO Addresses Obtain your ICAO address from your local aeronautical authority.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • Aircraft information (tail number, fuselage/airframe number, manufacturer and model, and country of registration) • List of services required (for example, Swift 64 Mobile ISDN, Aero H+ data-2, SBB PS and SBB CS services) NOTE: When requesting a logon class, you must request Class 3, even if your installation does not support data services. The channel card software does not support Class 2. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal E. Configuring User ORT Parameters with the Maintenance Port Utility (MPU) You can use the MPU to configure user-level parameters in the ORT. This feature will be available in a future release. F. Configuring Secure ORT Parameters with the Maintenance Port Utility (MPU) You can use the MPU to configure secure-level parameters in the ORT.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (2) Changing Default LESs Using the MPU The LES Access Codes can be configured using the HSD-440 Mark 2 Terminal MPU. You can access the MPU by connecting a computer running a VT100 terminal emulation program to the RS-232 maintenance port on the HSD-440 Mark 2 Terminals. Refer to "Test and Fault Isolation" on page 4-35 for connection settings and cabling information).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (b) Connecting to the Maintenance Port To connect to the maintenance port: • Connect a computer running a terminal emulation program to the HSD-440 Mark 2 Terminal maintenance port, and then power up the system. (Refer to "Test and Fault Isolation" on page 4-35 for detailed connection information.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal L. Verifying Configurations This section describes how to view the HSD-440 Mark 2 Terminal configuration parameters. To view the HSD-440 Mark 2 Terminal ORT system configuration: 1. In Menu 3, press o. The List ORT appears. 2. To scroll through the listing until you see a table of ORT ORs, press o. The LES Access Codes are listed in this table. 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Each dialing sequence component serves a different routing function: • Dial Code Prefix: Use service-specific dial code prefixes when sending a fax or using analog modems, or for overriding system defaults to force the system to request a specific service type. Figure 2-1 uses the dial code prefix for 3.1 KHz audio service type (*82*). See Table 2-2 for other dial code prefixes.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 2-2 Dial Code Prefixes for Forcing Service Type Selection (Continued) Service Type Service Description Dial Code Prefix (Forces service selection) SBB Prefixes Speech 64 kbps N/A 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 2-3 Dial Code Prefixes for System Overrides Dial Code Prefix Reason for Override Use this dial code prefix to override the default LES/GES configured in the system. This dial code prefix signals the system to override the default LES/GES and use the selected LES/GES instead. (See Figure 2-2 or contact Inmarsat for Swift 64 LES/GES codes) Use with fast (e.g.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal B. Placing Calls with the CEPT-E1 Interface HSD-440 Mark 2 Terminal CEPT-E1 interface provides Cabin Telecommunication Unit (CTU) access to two Aero-H+ 4800 bps AMBE voice calls simultaneously. Since the CEPT-E1 interface shares the Aero H+ voice channels with the cockpit, CTU calls maybe preempted from either the air or ground by higher priority calls.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 1 S A T COM 1L 3 2L 5 * MAKE MA I N MENU 1R S A T 1 A V A I L A B L E P R I CA L L 3 2R 0 0 1 6 1 3 5 6 0 1 2 4 3 3L 7 3R S A T 4L 2 I N C O M I N G 9 * A N S WE R CA L L C A L L REJ ECT * 4R P U B L I C 5L 11 E 6L 13 < S U B M E N U D I RECTORY > 5R 6R Figure 2-3 MCDU Screen The top of the screen displays the title of the menu on the screen.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • * appears at the far left or right to indicate that pressing that key results in an action. • NUMBER/NUMBER appears to tell you which page out of how many pages you are viewing. For example, 1/3 would appear when you are on page 1 of 3 pages in total. • [ and ] appear around empty data fields where you can enter data. However, entering data is not mandatory in these fields.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal This section will help you perform the following tasks: • Viewing Flight Information • Logging On and Off • Viewing Channel Information • Configuring Headsets (7) Viewing Flight Information You can view the flight identification from the MCDU. To view flight information: 1. On the first page of the MCDU’s main menu, press the key next to SUBMENU. The SATCOM SUBMENU page appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (a) Viewing the Log Status The log status defines whether the HSD-440 Mark 2 Terminal is currently logged on or logged off. The logon status can be: • Logged-Off—The HSD-440 Mark 2 Terminal is logged off. • Logged-Off Inop—The HSD-440 Mark 2 Terminal is configured to log on manually but the terminal is in an inoperable state. Clear all problems for the logon to continue.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To log on automatically: 1. On the main page of the MCDU, press the key next to SUBMENU. The SATCOM SUBMENU page appears. 2. On the SUBMENU page, press the key next to LOG-ON. The SATCOM AERO LOG-ON page appears. 3. On the SATCOM AERO LOG-ON page, press the key next to AUTO LOG-ON. The HSD-440 Mark 2 Terminal logs on and the logon state is LOGGED-ON AUTO.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal GES S E L EC T I ON 1 / 3 A O R W * AUS S AGUE L / 0 0 5 A O R W * E I K / 0 0 2 A O R E * AUS S AGUE L / 1 0 3 A O R E * E I K / 1 0 4 P O R * PERTH / 2 0 5 RETURN> 4. To select a GES, press the button next to the GES name. A logon confirmation (LOG-ON) appears at the bottom of the screen. 5. To log on to the new GES, press the key next to LOG-ON.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • SBB (SwiftBroadband) • Number of bits transmitted per second (TX KBPS)—for Swift 64 MPDS or SBB background services, the number of bits being transmitted per second is expressed in kilobits per second (kbps).Otherwise, the number of bits transmitted is zero.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal S A T COM CH 3 ST AT CHAN SYNC L O G O N WA I T FOR C A L L P T E R M T X K B P S 0 . 0 0 T X E I R P R X K B P S 1 3 . 5 R X 0 . 0 0 C / N 0 C O N N E C T E D 5 0 . 0 E I K S E R V AERO T Y P E S A T P / R / T AORE B 5 RETURN> S A T COM CH 4 ST AT L O G O N VA L I D C A L L T E R M T X K B P S 0 . 0 0 T X E I R P R X 0 . 0 R X K B P S 0 .
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal S A T COM HSD ST ATUS 3. On the SATCOM HSD STATUS page, press the key next to a Swift 64 channel. The SATCOM CH STAT page appears. S A T COM O R R CH 1 ST AT S T A T REG I S T ER I NG C A L L T E R M T X K B P S 0 . 0 0 T X E I R P R X 1 4 . 0 R X K B P S 0 . 0 0 C / N 0 C O N N E C T E D 5 3 .
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal S A T COM 3. On the SATCOM HSD STATUS page, press the key next to the SBB channel. The SATCOM CH STAT page appears. S A T COM CH 1 ST AT A T T A C H YES C A L L T E R M T X K B P S 0 . 0 0 T X E I R P R X 2 0 . 0 R X K B P S 0 . 0 0 C / N 0 C O N N E C T E D 7 2 .
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal S A T COM MA I NT ENANCE ST ATUS T E R M I N A L T R A N S M I T OK NORMA L The maintenance menu displays the following information: • Terminal status on the line below TERMINAL—Terminal status may be OK or FAULT. • Transmit status on the line below TRANSMIT—Transmit status may be NORMAL or INHIBITED.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • 15-digit IMSI number (11) Configuring Headsets To configure the headset(s): 1. On the main page of the MCDU, press the key next to SUBMENU. The SATCOM SUBMENU appears. 2. On the SATCOM SUBMENU page, press the key next to MAINTENANCE. The SATCOM MAINTENANCE page appears. 3. Press the key next to HEADSET CONFIG. The SATCOM HEADSET CONFIG page appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal F. Performing Cockpit Communications with the MCDU This section provides instructions for making calls with the MCDU and 4-wire voice services available in the aircraft’s cockpit. The cockpit communications system operates with one or two headsets in the aircraft’s cockpit, depending on the operational mode.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 2-4 Call Discrete Outputs in HSD-440 Mark 2 Terminal Audio Discrete Channel State Digital Audio System Light Digital Audio System Chime Alternate Discrete Discrete 1 Discrete 2 On hook Off Off Off Off Call initiated/connected 1 Hz flash Off On Off Call answered Steady or 3 Hz flash Off Off On Incoming call 1 Hz flash Single-stroke On On To accept the call: • On the first page of the MC
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal S A T COM D I RECTORY < C A T EGOR Y 0 1 C A T EGOR Y 0 3 > < C A T EGOR Y 0 2 C A T EGOR Y 0 4 > S A T 2 [ M A N U A L D I A L ] P R I 3 RETURN> 2. To select a channel, on the SATCOM DIRECTORY page, press the key next to SAT (the channel number). 3. To set the priority for your call using Table 2-5, type the priority number on the MCDU scratchpad and press the key next to PRI (the priority value).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (d) Making Calls from the Telephone Directory You can make voice calls from the numbers you have saved in the MCDU’s telephone directory. The HSD-440 Mark 2 Terminal MCDU enables you to keep four separate telephone books for different uses. By default, these books are called Category 01, Category 02, Category 03, and Category 04. You can customize the directory names in the HSD-440 Mark 2 Terminal ORT.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 3. To dial or load a telephone number, press the key next to the number. With Pre-Select mode disabled, the MCDU main menu page appears and the HSD-440 Mark 2 Terminal starts the call. With Pre-Select mode enabled, the MCDU main menu page appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To save telephone numbers to the telephone directory: 1. On the main page of the MCDU, press the key next to DIRECTORY. The SATCOM DIRECTORY page appears. 2. To view telephone numbers stored in a directory, press the key next to the directory name. The directory listing appears. 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 2-30 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal INSTALLATION This section provides procedures to install HSD-440 Mark 2 Terminals on an aircraft, including the following sections: • Advisories • Pre-Installation Inspection • Mechanical Installation • Electrical Installation • Passive Intermodulation (PIM) Test • Installation and Engineering Diagrams 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (1) Cabling When installing the HSD-440 Mark 2 Terminal, follow the cabling requirements listed below: • Maximum recommended length for Ethernet cables is 50 feet. • LAN cables must meet flammability, TIA/EIA568-A CAT 5, requirements and conform to ARINC 628 specifications.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal When selecting an installation location for the HSD-440 Mark 2 Terminal, consider the heating and cooling requirements listed below: • Power Dissipation (AC/DC models): 275 Watts nominal, 400 Watts maximum • Cooling Air: per ARINC 600 • Recommended Flow rate: 88 kg/hr (185 lbs/hr) • Pressure drop: 5 ±3 mm (0.07 ±0.025 in.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal C. Chassis Grounding The HSD-440 Mark 2 Terminal tray-mounted assemblies must be electrically bonded to the airframe. Make sure that the mating surfaces are free from contaminants such as paints or other non-conductive elements. Where surface preparations are insufficient to ensure a proper bond, EMS Aviation recommends using a short, tin-coated, copper bonding strap of at least 6.35 mm (0.25 in.) in width.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-1 Cable Shielding and Termination Specifications Conductor Type (Typical) Cable Function Single Point N/A Multiple Point Minimum Conductor Coverage By Shield N/A N/A Power Lines Single conductor, stranded Digital Control Twisted pair, stranded Yes 85% Serial Data Twisted pair, stranded Yes 85% Ethernet Data Twisted pair, stranded Yes 85% ISDN Data Twisted pair, stranded Yes 85% Discre
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The HSD-440 Mark 2 Terminal maintenance port is available at the front of the HSD-440 Mark 2 Terminal and at the rear ARINC 600 connector. Connection on the front of the HSD-440 Mark 2 Terminal is accessible via a DB25S connector for local maintenance of the terminal. Remote access is provided for cases where local access is unavailable. For remote access, install an accessible DB9S connector in the cabin area.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-3 WOW Pin Wiring Pin Name and Location WOW1 WOW2 PGM TP3G TP3K TP3J CLOSED CLOSED CLOSED In-air OPEN CLOSED CLOSED Not valid—Default in-air CLOSED OPEN CLOSED Not valid—Default in-air OPEN OPEN CLOSED On-ground CLOSED CLOSED OPEN On-ground OPEN CLOSED OPEN Not valid—Default in-air CLOSED OPEN OPEN Not valid—Default in-air OPEN OPEN OPEN In-air Aircraft Status WOW discret
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-2 ICAO ID, Hex to Binary Conversion A pin strapped to the same potential as TP7K is considered a logical 0, whereas an open circuit pin is considered a logical 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (6) Remote Status Panel (Optional) An optional remote status panel may be installed when HSD-440 Mark 2 Terminals are located in inaccessible or remote locations. The installation of a remote status panel is recommended as it provides visual indications of the power and faults for each terminal. A remote reset switch for HSD-440 Mark 2 Terminals can also be installed and located with the remote status panel.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-4 Remote LED Panel Circuit (7) System Configuration Strapping The HSD-440 Mark 2 Terminal adjusts its configuration according to the status of several strap pins on the rear ARINC 600 connector. Configuration pins are assigned based on system mode configuration selection and data I/O requirements, as shown in Table 3-4. Detailed pin assignment is shown in Table 3-5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-5 System Pin Strapping Pin Status System Mode TP4A TP4B TP4C TP4D Valid - provides Aero H+ services only 0 1 0 0 Valid - provides Aero H+ and Swift services 0 1 0 1 All other combinations are invalid and could cause an operating failure. NOTE: The logic for the System Configuration pins is reverse to the logic explained in ARINC 741 Characteristic Attachment 1-4, Note 19.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-8 Priority 4 Call Configuration Strapping Pin Number TP4F Name Function Inhibit Priority 4 Calls Determines whether priority 4 calls are inhibited to and from the cockpit. When these calls are inhibited, incoming calls are not allowed, and outgoing priority 4 calls are rejected.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-5 RJ45 Connector Terminator Details Table 3-10 RJ45 Wiring Details Service EURO ISDN SIGNAL PIN ETHERNET 10BASE-T CABLE ECS OTHER PIN CABLE ECS OTHER RX+ 3 White White/green 3 White White/orange stripe RX- 6 Blue Green 6 Green Orange/white stripe or solid orange TX+ 4 White Blue 1 White White/green stripe TX- 5 Orange White/blue 2 Brown Green/white stripe or solid Green U
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • IRS#1 A TP4J • IRS#1 B TP4K • IRS#2 A TP5C* • IRS#2 B TP5E* You can configure IRS#2 as a secondary IRS bus, or an input bus for the AES ID. (b) Antenna Interface The ARINC 741 antenna subsystem BSU is connected to the HSD-440 Mark 2 Terminal as specified in Table 3-11.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (c) CMU Interface Data rates, voltage thresholds, and electrical interface specifications are per ARINC Specification 429. (741 p2-7 p4.7.2). The ARINC 600 wiring interconnections for the HSD-440 Mark 2 Terminal and each CMU are shown in Table 3-12.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 5. Passive Intermodulation (PIM) Test This section describes the passive intermodulation (PIM) test. You must execute the PIM test after installation, if theHSD-440 Mark 2 Terminal operates in SwiftBroadband mode. A. Overview To meet Inmarsat requirements for SBB operation, the HSD-440 Mark 2 Terminal can test for passive intermodulation effects.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal D. PIM Test Results (1) PIM Test Overall Status At the end of the PIM test, the HSD-440 Mark 2 Terminal displays the test results. Figure 3-6 shows an example of the test results.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal PIMBIT REPORT: OVERALL STATUS PASS TEST STARTED: Jan 16 08:15:58 2001 ICAO ADDRESS: NOT OBTAINED TEST ENDED: Jan 16 08:20:36 2001 ANTENNA SERIAL NUMBER: 456 TESTED USING MANUALLY ENTERED FREQUENCIES TRANSMIT CHANNEL 1 = $1CE8 (1630.000 MHz) TRANSMIT CHANNEL 2 = $4268 (1654.000 MHz) RECEIVE CHANNEL = $4B00 (1558.000 MHz) INTERMOD ORDER = 7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The first line of the PIMBIT report displays the overall PIM status. If the overall status is PASS, the HSD-440 can continue to use SBB services. If the overall status is FAIL: • Check the cable connections of the antenna and the HSD-440 Mark 2 Terminal. • Check the direction in which the test failed and verify that the antenna is not blocked in that direction—see "Directional PIM Test Results" on page 3-19.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-14 HSD-440 Stand-Alone Terminal Top Plug Connection Details I/O From Top Plug Signal Name To Description I 1A CMU 1 Input A CMU 1 TP1A CMU 1 RX A I 1B CMU 1 Input B CMU 1 TP1B CMU 1 RX B O 1C CMU 1/2 Output A CMU 1/2 MP2C CMU 1/2 TX A O 1D CMU 1/2 Output B CMU 1/2 MP2D CMU 1/2 TX B I 1E ARINC 615 Input A I 1F ARINC 615 Input B O 1G ARINC 615 Output A O 1H ARINC 615 Output B
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-14 HSD-440 Stand-Alone Terminal Top Plug Connection Details (Continued) I/O From Top Plug Signal Name To Description I 3A Top/Port HPA MUTE A MA: Not required OA: BSU, PORT-G HPA Mute-A, Port BSU I 3B Top/Port HPA MUTE B MA: Not required OA: BSU, PORT-H HPA Mute-B, Port BSU I 3C STBD HPA MUTE A MA: Not required OA: BSU, STBD G HPA Mute-A, STBD BSU I 3D STBD HPA MUTE B MA: Not required O
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-14 HSD-440 Stand-Alone Terminal Top Plug Connection Details (Continued) I/O From Top Plug Signal Name To Description G=0(strapped), 4H=1(open) Steady lamp, multi-stroke chime I 4G 4G=1(open), 4H=0(strapped) Flashing lamp, single stroke chime Chime/light option MS 4G=1(open), 4H=1(open) Steady lamp, single-stroke chime I 4H Chime/light option LS I 4J IRS 1A Aircraft main IRS IRS 429 data, Rx HI
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-15 HSD-440 Stand-Alone Terminal Middle Plug Connection Details I/O From Middle Plug O 1A Discrete output 1 Remote status panel HSD-440 Mark 2 Terminal-Power On (Optional) O 1B Discrete output 2 Remote status panel HSD-440 Mark 2 Terminal-Fault (Optional) 1C Spare 1D Switch HI current from chime 1E 1D 1E outputs to Audio control panel O 1F Discrete Common Remote status panel Discrete Comm
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-15 HSD-440 Stand-Alone Terminal Middle Plug Connection Details (Continued) I/O From Middle Plug Signal Name To Description I 3D Place/end 1 Audio Management System I 3E MCDU 2 input A MCDU 2 J4-27 MCDU 2 RX A I 3F MCDU 2 input B MCDU 2 J4-28 MCDU 2 RX B O 3G Call light 2 Audio Control Panel I 3H Mic on 2 Audio Management System I 3J Go-ahead / Chime reset Audio Control Panel I
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-15 HSD-440 Stand-Alone Terminal Middle Plug Connection Details (Continued) I/O From Middle Plug Signal Name To I 6A ISDN 1 Rx+ ISDN, RJ45-3 I 6B ISDN 1 Rx- ISDN, RJ45-6 O 6C ISDN 1 Tx+ ISDN, RJ45-4 O 6D ISDN 1 Tx- ISDN, RJ45-5 I 6E Input Audio 2 HI I 6F Input Audio 2 LO Description User data, ISDN-1 Refer to "User Interfaces" on page 3-12 Cockpit Headset 2 Microphone HI O 6G 10BA
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 3-16 HSD-440 Stand-Alone Terminal Bottom Plug Connection Details I/O From Bottom Plug Signal Name To Description I BP2 +28 V dc HOT Aircraft power source, HOT I BP3 +28 V dc return GND Aircraft power source, return I BP8 Chassis GND Aircraft ground I/O BP4 Reserved I/O BP5 Spare I/O BP6 Reserved I BP1 115 V ac HOT Aircraft power source, HOT I BP7 115 V ac COLD Aircraft power sou
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-7 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 3-28 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-8 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 3-30 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-9 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 3-32 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 3-10 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 3-34 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal TEST AND FAULT ISOLATION This chapter provides information required to determine the operational readiness of HSD-440 Mark 2 Terminals and aid service personnel in diagnosing system faults. The operational and diagnostic tests described in this section require using the HSD-440 Mark 2 Terminal’s built-in diagnostic tool, the MPU.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-1 List of Required Test Equipment Item Equipment Specification Quantity Computer Standard VT-100 386 CPU, 20 MHz or higher VT-100 terminal emulation program HyperTerminal©, ProComm Plus©, or equivalent Serial communication program using an 1 RS-232 port Cable, maintenance port interface cable Special Remote access maximum cable length 1 25 ft.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (2) Connection Requirements This section describes specific cabling requirements needed to connect to and use the HSD-440 Mark 2 Terminal MPU. (a) Cabling Notes The HSD-440 Mark 2 Terminals provide two options to connect to the HSD-440 Mark 2 Terminal maintenance port and MPU: direct connection and remote connection.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure 4-1 Remote Connection, Maintenance Cable Figure 4-2 Direct Connection, Maintenance Cable (c) Interface Requirements A standard VT-100 compatible terminal running an emulator program (such as HyperTerminal, ProComm Plus, or similar) provides the user interface to the HSD-440 Mark 2 Terminal MPU. The RS-232 terminal connection settings for HSD-440 Mark 2 Terminal maintenance ports are listed in Table 4-5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-5 Terminal Connection Settings Parameter Setting Character Format ASCII Baud Rate 19200 bps No. of bits 8 Parity None Stop bits 1 Flow Control None (3) Accessing the MPU There are various levels of access to the MPU. Each level is protected by a different password. This document describes End User and Field Representative access levels.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (b) Navigating the Terminal MPU • To scroll through the available menus, press CTRL+N. • To go to the previous menu, press CTRL+O. • To refresh the menu screen or exit from a Reports Menu, press ESC. (c) Selecting Menu Items To enable test or data entry functions, press the letter associated with the menu items.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MENU 1 FIRMWARE Vx.x GND X override forward id/ICAO address L test LEDs Y explain error status U list event log (hex) F print equipment stats M clear equipment stats N permit TFTP software loads N next menu O previous menu = select reports Menu 1 Screen Display Table 4-6 Menu 1 Item Descriptions Menu Item Description X: override forward id/ICAO address Used in testing and fault isolation.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MENU 2 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-7 Menu 2 Item Descriptions (Continued) Menu Item Description R: resume automatic steering Re-activates programmed automatic antenna-steering in both azimuth and elevation. N: annotate log file Allows for input of text into a log file. This feature can be used to document information such as test conditions, system or aircraft identification, or any pertinent information for later review.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-8 Menu 3 Item Descriptions (Continued) Menu Item Description O: list ORT Displays all EEPROM parameters, including all cable losses and LES/GES configurations. I: set all LES id's Displays all ORT parameters to the same LES/GES access code and service provider (including primary and secondary service providers). Certain parameters are set using Menu 3, set CP ORT parameter.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MISCELLANEOUS PARAMETERS 1 HPA-TO-ANTENNA TOTAL LOSS 2 FORWARD ID 3 GPS PROTECTION ALGORITHMS 11 FRONT PANEL LEDS ENABLED 14 MAINTENANCE PORT INVERSE VIDEO 15 MAINTENANCE PORT DEGREES SYMBOL 16 TERMINAL CATEGORY 20 CARD 1 IP ADDRESS 21 22 29 30 31 63 64 65 CARD 2 IP ADDRESS TRANSMIT IF WEIGHT-ON-WHEELS DEFAULT LATTITUDE DEFAULT LONGITUDE OBEY OXCO STATUS CARD 1 SUBNET MASK CARD 2 SUBNET MASK AIR/GROUND BEHAVIOUR W
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-9 Menu 3, Item M EEPROM Parameter Descriptions (Continued) Parameter Number Parameter Name Description 14 Maintenance port inverse video Enables a selected report to be highlighted in Inverse Video when it is activated—default is 1 (activated).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-9 Menu 3, Item M EEPROM Parameter Descriptions (Continued) Parameter Number Parameter Name Description 83 IP Header Compression Turns on IP header compression. Valid values: C (channel card default = Off), 0 (Off), and 4 through 9 (On) 95 Over Power Margin Do not change.2 97 Channel Card Configuration Configures channel cards for Swift64, SBB, or classic service.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MENU 4 1252-A-3800-01 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MENU 10 A F G T R Q B N 1252-A-3800-01 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-11 Menu 10 Item Descriptions (Continued) Menu Item Description M: activate antenna Activates all set antenna status words. status words D: toggle active antenna Changes the current simulated active antenna. Choose starboard, port, or automatic. Note that this change will only take effect if antenna status words are activated using menu item M.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (g) Menu 14 Menu 14 items are used only by professional installers for debugging and clarifying call routing issues. Figure 4-9 shows an example HSD-440 Mark 2 Terminal MPU Menu 14 screen display. Table 4-13 describes some of the items available in Menu 14. MENU 14 1252-A-3800-01 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-14 Menu 15 Item Descriptions Menu Item Item Description V: request channel card versions Displays software versions for a selected channel card. B: channel card RSSI Places the channel card in Received Signal Strength Indicator mode. mode As requested, enter the channel number, the OR, the channel type, and the RSSI period in milliseconds. W: request burst counter Displays the burst counter information.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (j) Menu 30 Figure 4-12 shows an example HSD-440 Mark 2 Terminal MPU Menu 30 screen display. Table 4-16 describes some of the items available in Menu 30. NOTE: For more information about PIM testing, refer to "Passive Intermodulation (PIM) Test" on page 3-16. MENU 30 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 1 OFF OFF messages to card #1 2 OFF OFF hex output to card #1 3 OFF OFF responses from card #1 4 OFF OFF hex input from card #1 5 OFF OFF card #1 misc info 6 OFF sb antenna arinc input 7 OFF sb antenna maintenance word 8 OFF sb antenna status word 9 OFF channel card call status 10 OFF channel card THA codes 11 OFF channel card errors 12 OFF IRS input 13 OFF messages to card #2 14 OFF hex output to card #2 15 OFF res
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 96 OFF IRS data rate 107 OFF unusual channel card msgs 108 OFF channel card rf pwr detect 109 OFF channel card power SU's 110 OFF underdraft debugging 111 OFF miscellaneous digital outputs 112 OFF arinc labels 113 OFF channel card sw loads 114 OFF all channel card THA codes 115 OFF OCXO state toggles 116 OFF DATA I/O passthrough mode 117 OFF output to data i/o (ascii) 118 119 120 121 122 123 124 125 126 127 128 129
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Enter 1 thru 203 to toggle report on/off X turn off all reports N show next page S save to EEPROM ESC return to PREVIOUS MENU 181 OFF data i/o call reports 194 OFF PA reset cycles 182 OFF recovery after BGAN inert 195 OFF sys table protection algorithm 183 OFF debug CC#1 rx parser 199 OFF classic AERO call status 184 OFF debug CC#2 rx parser 202 OFF CFDS pages sent to CMC 185 OFF dio / cc call matchup 203 OFF
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 1. Reports 23 and 94 Report 23 is the most comprehensive report, giving a general impression of the HSD-440 Mark 2 Terminal health. An example of the contents of report 23 is shown in Figure 4-14. Table 4-17 provides an example and a brief description of the parameters. Each distinct parameter is numbered for description purposes.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-17 Report 23 Item Descriptions (Continued) Report 23 Text Description HD 83.9D Aircraft true heading; where the nose of the aircraft is pointing, based on yaw offset TK 0.0D Aircraft true track; direction the aircraft is flying—not necessarily the direction it is pointing (see note below) 0 knots Aircraft velocity NOTE: When the aircraft is stationary, the field may appear as a series of asterisks (*).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal These reports are commonly used for testing and troubleshooting the system and are only available to Level 2, maint access users. NOTE: Depending on the version of software installed and the user's selection of reports, the MPU reports displayed may differ from those shown in the example in Figure 4-17. port status $608033 SDI: ACU SSM: NORMAL gain=12.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-19 Report 21 Item Descriptions Report 21 Call Codes (Time) - Time based on the system real time clock (Fwd Addr) - Forward address ID assigned to the system channel cards (Alpha/no.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal CAUTION: CHANGES TO DEFAULT VALUES FOR SOME MENU FUNCTIONS MAY SERIOUSLY DEGRADE SYSTEM OPERATION. NOTE: This manual describes the basic MPU functions, menus, and reports required for the testing and fault isolation procedures presented in this section. Please consult Honeywell Product Support before entering any unfamiliar menu selections not described in this manual.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (3) Installation and Operational Verification Tests The test procedures assume that an approved ARINC 741 compatible antenna subsystem has been completely installed and tested as per the manufacturer's instructions. To facilitate and document the installation of the equipment, refer to "Installation Checklist" on page E-1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-23 HSD-440 Mark 2 Terminal Electrical Verification Checklist (Continued) STEP 2.0 Item Checked Voltage levels Verification Description CAUTION: WHEN POWER IS APPLIED TO THE RACK, THE FAN ENERGIZES. Check voltage levels: 28 V dc: between BP2 (positive) and BP3 (return) or 115 V ac: between BPI (115-H) and BP7 (115-C) 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (a) Parameter Verification Procedure • From Menu 3, press H (list SCM/CP ORT), and then press 1 (CP EEPROM ORT). The ORT listing appears on the screen, as shown in Figure 4-19. Verify that the correct system configuration parameters are listed in the ORT.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 0 lists SCM ORT -- 1 lists CP EEPROM ORT -- 2 lists CP ORT OPTIONS ? CP EEPROM ORT: ID A8E09293 VERSION 30026 4-WIRE #1 NOISE LEVEL: -50 4-WIRE #1 SPEAKER LEVEL: 50 4-WIRE #1 MIC LEVEL: 70 4-WIRE #1 SIDETONE LEVEL: 50 4-WIRE #2 NOISE LEVEL: -50 4-WIRE #2 SPEAKER LEVEL: 50 4-WIRE #2 MIC LEVEL: 70 4-WIRE #2 SIDETONE LEVEL: 50 MCDU TYPE: HONEYWELL NOT DEFAULT HSD SAL: 307 LOG-ON/HANDOVER POLICY: MANUAL NOT DEFAULT HIG
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MCDU FONT COLOUR: ENABLED NOT DEFAULT SET BY MAINT PORT COCKPIT OUTGOING CALL SIGNALING: DISABLED SET BY MAINT PORT COCKPIT OUTGOING CALL PRE-SELECT: ENABLED SET BY MAINT PORT PIMBIT AZIMUTH OFFSET ANGLES: SET BY MAINT PORT HGA = 11.0 DEG NOT DEFAULT IGA = 15.0 DEG NOT DEFAULT PIMBIT IGA ELEVATION ANGLES: SET BY MAINT PORT ANGLE 1 = 18.0 DEG NOT DEFAULT ANGLE 2 = 12.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal LES INFORMATION: AORW: LES 2 AORE: LES 2 POR: LES 2 IOR: LES 2 NETWORK NETWORK NETWORK NETWORK SATELLITE FREQUENCY TABLE: REGION 0: GLOBAL BEAM FREQS: REGION 1: GLOBAL BEAM FREQS: REGION 2: GLOBAL BEAM FREQS: REGION 3: GLOBAL BEAM FREQS: REGION 4: GLOBAL BEAM FREQS: REGION 5: GLOBAL BEAM FREQS: GLOBAL BEAM FREQS: $2BA0,$9E REGION 7: GLOBAL BEAM FREQS: ID ID ID ID 0 0 0 0 LES 2 NO NAME NO NAME NO NAME $FFFF,$FFFF
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (5) System Power-up Checks NOTE: Before proceeding, make sure that all pre power-up, mechanical, and electrical verifications have been successfully performed and documented using "Installation Checklist" on page E-1. (a) Preparation The following tests serve primarily to confirm proper system power-up; therefore, they can be performed while the aircraft is still in the hangar.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal KERNEL V1.7 -- Wed Mar 24 13:09:23 2010 TESTING RAM ......RAM OK. CONFIDENTIAL PROPERTY OF EMS TECHNOLOGIES CANADA, LTD. USE AND DISTRIBUTION LIMITED SOLELY TO AUTHORIZED PERSONNEL. The use, disclosure, reproduction, modification, transfer or transmittal of this work for any purpose, in any form, or by any means without the written permission of EMS Technologies Canada, Ltd. is strictly prohibited.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal SOFTWARE: EMS: BOOT APP. CC #1 CC #2 PART NUMBER LI-1252-38015 CRC: CRC: CRC: CRC: SECURE ORT: USER ORT: REVISION XXX 5249CAFF A3A3D6B7 CBA1 9F4E sss123 uuu456 ** MODIFIED ** ** MODIFIED ** Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization. time 21.5 seconds: powering on channel card 2 time 23.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 3. To access the reports menu, press EQUAL SIGN, and then activate reports 21 (call codes) and 23 (standard output). Remember to save these selected items by pressing S (save to EEPROM). 4. To reset the HSD-440 Mark 2 Terminal, in Menu 2, press Z, and then immediately type the password maint when the reset messages appear. The data from the previously selected reports 21 and 23 appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 45D0'0.0"N 75D0'0.2"W PT 0.0D RL 0.0D HD 0.0D TK 0.0D 0 knots 0 ft 17:12:39 dop 0 ppb az 112.2 deg el 12.2 deg AORE ant gain 12.0 (sbd) CHAN #1: C/No=51.4 dB Hz sig=-31.4 dB 41.5 C no call beam=4 CHAN #2: C/No=51.5 dB Hz sig=-32.6 dB 41.5 C no call beam=5 CHAN #3: C/No=48.9 dB Hz sig=-26.1 dB 40.0 C log on beam=4 CHAN #4: C/No= 0.0 dB Hz sig= -0.0 dB 40.5 C no call beam=4 45D0'0.0"N 75D0'0.2"W PT 0.0D RL 0.0D HD 0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (a) Preparation • Perform all previous tests and document the results before proceeding. • As directed in previous tests, connect a computer to the maintenance port and use the Level 2 password to access the HSD-440 Mark 2 Terminal MPU. • Power up all avionics and align the IRS. • Taxi or tow the aircraft to an unobstructed, line-of-sight location where a complete 360° rotation is possible.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • Voice/data calls—in flight: Place any combination of voice and/or data calls during flight. The flight pattern may include "standard rate of turn," figure 8, or circles. Note any voice or data anomalies. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (1) Fault Isolation Screen Displays Figure 4-22 to Figure 4-31 provide example maintenance screens for reference and illustration purposes. time 8.6 seconds: powering on channel card #2 card is already on SENDING FIRST OC_RESTART COMMAND time 22.1 seconds CHAN #2 CONTROL PROCESSOR TRIGGERING ORR IN AORE!! SENDING FIRST OC_RESTART COMMAND time 22.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 12:43:55 dop**** az 285.4 deg el 15.3 deg AOR EAST ant gain 12 (p/t) CARD #1: C/No=52.9 dB/Hz sig=-33.9 dB 27 C no call beam=4 CARD #2: C/No=52.9 dB/Hz sig=-34.2 dB 27 C no call beam=4 ************ *********** ********* ******** ********* ******* ******* CARD #1: C/No=52.4.0 dB/Hz sig=-33.6 dB 27 C in call beam=4 CARD #2: C/No=52.4 dB/Hz sig=-34.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MENU 3 L list EEPROM C clear event log F list call log O list ORT I set all LES id's N next menu G clear call log N next menu HPA ERROR CODE 1800 hit '0' for complete log FIRMWARE Vx.x S M G P list event log misc.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Log-on password entered: "Maint" MENU 1 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal OMNIDIRECTIONAL MODE open loop tracking port/top active HGA LNA on port maintenance 0x00600003 port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port ant: status 608033 SDI=ACU gain 12 maint 600003 SDI=ACU port status: 0x60803
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation Fault Maintenance Report Description Red LED remains on after power-up • HPA uncontrolled HPA error status • reporting invalid SSM • HPA fault • HPA not reporting status word 143 • HPA not reporting maintenance word 350 Check View power-up display of the MPU • Verify that the multicontrol, loopback is wired (out to in).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Fault Call failure Maintenance Report Description IRS information not available Activate maintenance reports 21 and 23 Check • Check that the IRS systems are powered on and aligned. • Check that connections to the IRS systems are secured. • Check the polarity of IRS input lines.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Fault Call failure (cont’d) Maintenance Report Description ICAO is invalid or strapped incorrectly Activate maintenance report 21 To check ICAO, in Menu 4, press Q Check • The account registration process has not been completed.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Fault Logon request fails Maintenance Report Description Terminal is not transmitting Activate maintenance reports 21 and 23 Check • Check for defective or loose cables. • Check for antenna line-of-sight interference. • Check for HPA fault. • Make sure that the HSD-440 Mark 2 Terminal is secured properly to the ARINC connector in the tray.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Fault Logon successful, but fails to complete call Maintenance Report Description Authorization error (fault code 12C4) Activate reports 21 and 23 Check • Contact your service provider to verify that the ICAO, FWD ID, and IMSI are activated. • Check that the ICAO is strapped correctly. • Check that IRS data is available and correct.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Fault Maintenance Report Description HSD-440 Mark 2 Terminal is operating outside the normal environmental specifications Channel card temperature fault Activate report 21 or 23 Calls do not complete and connection is not established Channel Congestion (fault code 2024) Note: applies to Swift 64 only.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 4-24 Troubleshooting and Fault Isolation (Continued) Maintenance Report Fault Description Call drops after successful connection If the RF signal fades significantly (during a call), the connection may drop. Activate reports 21 and 23 NOTE: A sudden, severe aircraft banking angle may obstruct the signal long enough (>15 sec.) to drop a call. Check • Check signal strength.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To save a diagnostics reports file: 1. Open a log file on the maintenance port, terminal program. (If you are using HyperTerminal, use the "Transfer, capture text" function.) 2. Power the system on or if applicable reset the system. 3. Enter maintenance mode on the maintenance port using maint as the password. 4. To activate reports 21 and 23 and toggle off all other reports, press EQUAL SIGN. 5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 18. The log file is in text format (.txt file).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal MAINTENANCE AND REPAIR This section provides maintenance and repair information for the HSD-440 Mark 2 Terminal, including the following sections: • Maintenance • Repair • Instructions for Continued Airworthiness 1. Maintenance The HSD-440 Mark 2 Terminal does not require routine maintenance. 2. Repair All repair procedures must be completed by Honeywell-approved repair facilities. A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal F. Return for Repair Information Contact Honeywell International about return for repair instructions. 3. Instructions for Continued Airworthiness This section presents the instructions for continued airworthiness, as per FAR 25.1529, of the HSD-440 Mark 2 Terminal.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal CONFIGURING THE OWNERS REQUIREMENTS TABLE (ORT) There are two methods of configuring ORT parameters: • Configuring ORT Parameters Using the MPU • Configuring ORT Parameters Using the EMS ORT Application When your computer is connected to the HSD-440 Mark 2 Terminal through the serial maintenance connection, you can set ORT parameters one at a time.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 6-1 Configuring Secure ORT Parameters (Continued) Category Section Networking Parameters for Ethernet 1 Configuring the Host Name and Ethernet 2 Configuring the Access Concentrator Name Configuring the SNMP Server Configuring the SNMP Community String Configuring the TFTP Server Configuring the DHCP Client Configuring the DHCP Server Configuring Telnet Access Configuring the Managed Range Configuring the Numb
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 6-1 Configuring Secure ORT Parameters (Continued) Category MCDU Section Configuring MCDU Wiring Configuring the MCDU Input Speed Configuring the MCDU Output Speed Configuring the MCDU Controller Type Configuring the MCDU Type Configuring the MCDU Font Colour Configuring Manual Dialing Configuring Outgoing Call Pre-Selection Configuring the Address Book Categories CMU Configuring CMU Wiring Configuring the CM
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table 6-2 User ORT Parameters Category User Parameters User ORT Parameter Configuring the ORT Part Number (user) Configuring the Service Type Priority Configuring the Logon/Handover Policy Configuring Logon Interrogation Configuring High-rate R/T in Global Beam Masking Position in Logs A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal When you configure the parameter for the part number, the HSD-440 Mark 2 Terminal calculates a CRC value for the overall ORT. The HSD-440 Mark 2 Terminal uses the CRC value to indicate when the ORT has changed. To configure the secure ORT part number or the user ORT part number: 1. In the list of ORT parameters, type the number next to the SECURE ORT P/N parameter, or the USER ORT P/N parameter, and then press ENTER.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure ground public routing preferences: 1. In the list of ORT parameters, type the number next to the GROUND PUBLIC ROUTING PREFERENCE parameter, and then press ENTER. 2. To disallow all incoming public calls, type 1, or to route public calls to the cockpit, type 2, or to route public calls to the CEPT-E1, type 3, and then press ENTER. The default is DISALLOWED. D.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure the 4-wire noise level: 1. In the list of ORT parameters, type the number next to the 4-WIRE #1 NOISE LEVEL parameter, and then press ENTER. 2. At the prompt, define the default setting for the 4-wire #1 comfort noise insertion level by typing one of the following values: 0, -40, -50, or -60, and then press ENTER. The default level is -50. To configure the 4-wire speaker level: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (1) Configuring CEPT-E1 Interface The CEPT-E1 wiring parameter indicates whether the CEPT-E1 interface is wired. The CEPT-E1 wiring parameter is in the secure ORT. To configure CEPT-E1 wiring: 1. In the list of ORT interface parameters, type the number next to the CEPT E1 WIRED parameter, and then press ENTER. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure SCPC high speed service: 1. In the list of ORT parameters, type the number next to the ALLOW SCPC SESSIONS parameter, and then press ENTER. 2. To enable SCPC services, type 1, or to disable SCPC services, type 0, and then press ENTER. The default is YES. (3) Configuring MPDS High Speed Service The HSD-440 Mark 2 Terminal can provide access to Swift 64 MPDS service through Ethernet.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (2) Configuring Ethernet Duplex Mode You can define the duplex mode for the Ethernet ports. The available options are: • ETH1=HALF Duplex, ETH2=HALF Duplex • ETH1=FULL Duplex, ETH2=HALF Duplex • ETH1=HALF Duplex, ETH2=FULL Duplex • ETH1=FULL Duplex, ETH2=FULL Duplex The parameter for the Ethernet duplex mode is in the secure ORT. To configure Ethernet duplex mode: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal I. Configuring Networking Parameters For Ethernet 1 and Ethernet 2 (1) Configuring the Host Name You can configure the host name for the HSD-440 terminal with a string of up to 20 characters. The parameter for the host name is in the secure ORT. To configure the host name: 1. In the list of ORT parameters, type the number next to the HOST NAME parameter, and then press ENTER. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (5) Configuring the TFTP Server You can enable and disable the TFTP server. The TFTP server parameter is in the secure ORT. To configure the TFTP server: 1. In the list of ORT parameters, type the number next to the TFTP SERVER parameter, and then press ENTER. 2. To enable the TFTP server, at the prompt, type yes, or to disable the TFTP server, type no, and then press ENTER. The default is ENABLED.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure the managed range: 1. In the list of ORT parameters, type the number next to the START OF MANAGED RANGE parameter, and then press ENTER. 2. At the prompt, type the starting address in the format xxx.xxx.xxx.xxx, and then press ENTER. The default is 192.168.0.100.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (2) Configuring the Secondary IRS You can configure the type of equipment that provides input to the secondary IRS (IRS #2). The available options are: • Not installed—default • Inertial • AES ID • GNSS • Hybrid The secondary IRS parameter is in the secure ORT. To configure the secondary IRS type: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure GNSS equipment: 1. In the list of ORT parameters, type the number next to the A/C GNSS EQUIPMENT parameter, and then press ENTER. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (2) Configuring Satellite Information You can configure the name, location, and service available from up to eight satellites. This does not allow access to the satellite network. Satellite information is in the secure ORT. The default settings are: Entry # Region Satellite Name and Longitude 1 0 AORW (W) 53.0W CLASSIC AERO, SWIFT64 2 1 AORE (E) 15.5W CLASSIC AERO, SWIFT64 3 2 POR (P), 178.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (3) Configuring GES Service Provider Information You can configure the GES Name, satellite ID, GES ID, and priority for up to 33 GESs. GES information is in the secure ORT. Note the GES ID in the following table is an Octal number.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (4) Configuring the Frequency Table The Frequency Table defines the Global Band (SBB) and PSID (Areo H/H+) frequencies for up to eight satellites. You can configure two or more frequency pairs and NCS (S64) for each service type. The Frequency Table is in the secure ORT.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (5) Configuring LES Service Provider Information The LES Service Provider Table can hold LES parameters for up to eight satellites. The LES parameters are the satellite name and LES ID. The LES service provider information is in the secure ORT.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal is not specified, is not assisted. If the timing mode is not assisted, the HSD-440 Mark 2 Terminal is set as Aeronautical Class without GPS BGAN terminal. (7) Configuring the Priority Service for Channel Card One Channel card one can access SBB and Swift 64 services.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • ARINC 741 HGA, Side Mount If a third MCDU is installed, the HSD-440 Mark 2 Terminal cannot use the side-mount antenna. The antenna type parameter is in the secure ORT. To configure the antenna type: 1. In the list of ORT parameters, type the number next to the ANTENNA TYPE parameter, and then press ENTER. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The antenna mounting roll angle parameter is in the secure ORT. To configure the antenna mounting roll angle: 1. In the list of ORT parameters, type the number next to the ANTENNA MOUNTING ROLL ANGLE parameter, and then press ENTER. 2. Type a value between 0 and 360, to one decimal place, and then press ENTER. The default is 0.0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal M. Configuring MCDU ORT Parameters (1) Configuring MCDU Wiring The MCDU wiring parameter defines whether the MCDU can be wired or not wired. There is a parameter for each of the devices. The MCDU wired parameters are in the secure partition of the ORT. To configure the MCDU interface on the HSD-440 Mark 2 Terminal: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (5) Configuring the MCDU Type You can select the type of MCDU installed in the aircraft. The MCDU type parameter is in the secure partition of the ORT. To configure the MCDU type: 1. In the list of ORT parameters, type the number next to the MCDU TYPE parameter, and then press ENTER. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure outgoing call pre-selection: 1. In the list of ORT parameters, type the number next to the COCKPIT OUTGOING CALL PRE-SELECT parameter, and then press ENTER. 2. To enable pre-selection, type 1, or to disable pre-selection, type 0, and then press ENTER. The default is DISABLED.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure the CMU wiring: 1. In the list of ORT parameters, type the number next to the CMU #x WIRED parameter, and then press ENTER. The prompt: CMU #x WIRED? where x equals 1 or 2 appears. 2. To indicate that the CMU #1 or CMU #2 can be wired, type 1, or to indicate that the CMU #1 or CMU #2 cannot be wired, type 0, and then press ENTER.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (5) Configuring Hardcoded SAL The CMU-SDU hardcoded SAL parameter determines the SAL used in SDU to CMU Williamsburg messages. If this parameter is set to YES, a SAL of 304 is used regardless of the SAL reported to the CMU. If this parameter is set to NO, the SDU uses the SAL reported by the CMU. If a SAL is not present on the bus after one minute, the CMU uses a SAL of 304.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (3) Configuring Self-test in Air The HSD-440 Mark 2 Terminal’s MCDU or MPU can request a power-on self-test. The ORT parameter Self-test in Air determines if the self-test is permitted or not when the aircraft is in the air. This parameter is in the secure partition of the ORT. To configure self-test in air: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure field loadable software: 1. In the list of ORT parameters, type the number next to the SW FIELD LOADABLE parameter, and then press ENTER. 2. To enable the file transfers, type 1, or to disable the file transfers, type 0, and then press ENTER. The default is DISABLED.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal NOTE: This is the first of several checks that are performed before field software can be loaded. To mask position in logs: 1. In the list of ORT parameters, type the number next to the MASK POSITION IN LOGS parameter, and then press ENTER. 2. To enable position masking in logs, type 1, or to disable position masking in logs, type 0, and then press ENTER. The default is DISABLED.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal (3) Configuring PIMBIT IGA Elevation Offset Angle1 This parameter defines the first elevation pointing angle for PIM test offset when the terminal is configured to operate with an IGA. This parameter is in the secure partition of the ORT. To configure the PIMBIT IGA Elevation Offset Angl1e: 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To configure the PIMBIT Measurement Discard Ratio: 1. In the list of ORT parameters, type the number next to the PIMBIT MEASUREMENT DISCARD RATIO parameter, and then press ENTER. 2. Type a positive decimal number, and then press ENTER. The default is 5.0. (8) Configuring PIMBIT Failure Threshold This parameter defines the failure threshold level for the PIM test in dBs of channel degradation.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • Searching for an ORT Parameter A. Creating an ORT Configuration Creating an ORT configuration includes: • Opening the ORT file template • Editing parameters • Saving the ORT configuration To open an ORT configuration template: 1. Double-click on the ortedit.exe file. The EMS ORT Application opens. 2. Click File, and then click Open Package. The Choose ORT Package dialog box opens. 3. Navigate to the HSD440.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The EMS ORT Application organizes ORT parameters into functional groups. You can access each group by clicking on its tab at the top of the window. A lock symbol marks groups of secure ORT parameters, and an open lock symbol marks the group of user ORT parameters. Click the left and right arrows to see more tabs.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To edit ORT parameters: 1. Click on the tab for the functional group that contains the parameter you wish to edit. 2. Click on a parameter name in the Name column, then click on the parameter value in the Value column. For parameters with text or numerical values, the cursor appears. For parameters with preset options, a menu appears. NOTE: Some parameters are expandable.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The ORT Address book parameter includes four categories with 100 entries in each category. You can create and import a separate file for each category. The EMS ORT Application creates address book entries from imported Comma Separated Value (CSV) files that have the .csv file extension. You can create .csv files with Microsoft® Excel®. Importing a phone book includes: • Creating a .csv file • Importing the .
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 4. Save the spreadsheet as a .csv file. To import a .csv file: 1. Open the EMS ORT Application. 2. Open an ORT file or create a new file—refer to “Creating an ORT Configuration” on page 6-33 and “Opening a Saved ORT Configuration” on page 6-35. 3. In the EMS ORT Application, click File, and then click Import Phonebook. The Choose CSV File dialog box appears. 4. Click on the CSV file and then click Open.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal To load an ORT file into the HSD-440 Mark 2 Terminal: 1. Connect a computer to an Ethernet port and the Maintenance Port on the HSD-440 Mark 2 Terminal. 2. Copy the ORT file to the computer. 3. Start a HyperTerminal session to the Maintenance port of the HSD-440 Mark 2 Terminal. Section c: "Interface Requirements" on page 4-38 provides the settings for this connection. 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX A: INMARSAT SATELLITE BEAM COVERAGE Inmarsat operates strategically placed geostationary satellites called I-3 and I-4. I-3 satellites provide access to services such as Swift 64 and Aero H/H+, and I-4 satellites provide access to SBB and Aero H/H+ services. 1. I-3 Satellites Each I-3 satellite is located over and named after an OR.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The four satellite ORs are made up of smaller, spot-beam coverage areas. The following maps show the Inmarsat satellite spot-beam coverage for the four ORs, and a composite map of the four regions combined. NOTE: Figure A-2 and Figure A-3 depict Inmarsat's expectations of coverage but do not represent a guarantee of service and should not be relied upon.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Figure A-3 Inmarsat I-3 Satellite Beam Coverage—OR Maps 23-15-30 A-3 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 2. I-4 Satellites There are three I-4 satellites in service: • I-4 Americas (98W) • I-4 EMEA (25E) • I-4 Asia-Pacific (143.5E) Figure A-4 shows the I-4 satellite coverage regions.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX B: TROUBLESHOOTING CHECKLIST Before performing the detailed testing and troubleshooting procedures provided in this manual, read the following Troubleshooting Checklist. Use the Troubleshooting Checklist to make sure that you have not missed any key steps in the HSD-440 Mark 2 Terminal setup. 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 4. Is all cabling attached correctly and securely? Broken connections and improper cabling are the most common causes of HSD-440 Mark 2 Terminal malfunctions. Before proceeding with testing and troubleshooting, complete the following checks: • Check that all cables and wiring are routed and connected correctly and securely. • Make sure that the terminal is installed with the correct power source.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 3. To view GES preferences, type the number next to the GES preference, and then press ENTER. The GES priority table appears. The eNfusion® HSD High-speed Data Terminal Developer’s Guide, MN-1252-13005, provides more information about GES preferences.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 B-4 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX C: RJ45 CABLE TERMINATION DETAILS 23-15-30 C-1 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 C-2 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX D: INSTALLATION PLANNING CHECKLIST Installation Planning Steps 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Installation Planning Steps AMSISDN 5 CSFAX (3.1 kHz audio) 3. Pin Strapping The following strapping is required Item Strapped pins, e.g., TP1A to BP1A System Mode Data I/O (if applicable) 4. Wiring Antenna Multi-Control BITE A/B HPA Mute A/B Power ISDN: ISDN-1 Wire ISDN line. Channel 1 operates over ISDN 1 and channel 3 over ISDN-2 ISDN 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX E: INSTALLATION CHECKLIST Aircraft Identification: HSD-440 Mark 2 Terminal Model No: HSD-440 Mark 2 Terminal Installation Mode: HSD-440 Mark 2 Terminal Serial No: Name Signature Date Checks completed by: Approved/Witnessed by: Installation / Mechanical Section Parameter Item N/A 9 Value Service/maintenance access Physical Environmental considerations—see "Environmental Requirements" on page 3-
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Section Parameter Item N/A 9 Value + 28 V dc polarity Power Connections 115 V ac polarity Chassis grounding Voltage Levels Installation / Electrical IRS Input (x2) + 28 V dc level 115 V ac level IRS wiring IRS format SDI Config.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Heading Antenna Antenna (Deg) Selected Azimuth HSD-440 Mark 2 Terminal Swift 64 or SBB CH 1 CH 2 Classic CH 3 CH 4 CH 5 Note: Channels 3, 4, and 5 can be different than channels 1, and 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 E-4 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX F: CMU MESSAGES The CMU communicates with the HSD-440 Mark 2 Terminal using two types of communications: Broadcast messages and Bit Oriented Protocol (BOP) messages. Both types of communication are supported at the same time. This section includes descriptions of the messages that the CMU will transmit to the HSD-440 Mark 2 Terminal and receive from the HSD-440 Mark 2 Terminal.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal The CMU transmits its position in the cockpit to the HSD-440 Mark 2 Terminal using bits 9 and 10, as shown in Table F-2. Table F-2 Bits 9 and 10 Positions SDI 1 (bit 9) SDI 2 (bit 10) Position 0 0 Single 0 1 Left 1 0 Right 1 1 Not used Attachment 6 from ARINC Characteristic 758 describes the word format of this label. C.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal • Bit 32 indicates parity You can find the HSD-440 Mark 2 Terminal identity information in the ORT. If no information is available, the terminal identifies itself as SAL 307 by default. ARINC 781 Supplement 1 describes the word format of these labels. B. Understanding Status Word 1; Label 270 Bits are defined as shown in Table F-3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table F-3 Status Word 1 Bits (Continued) Bit(s) 15 Description If Set Message Alert with Chime • Refer to MCDU messages for timely information • Terminal should clear this bit once positive pilot response has been detected 16 Message Alert without Chime • This bit is never set, it is reserved for future use.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal C. Understanding Join/Leave Word; Label 271 Each of the Aeronautical Telecommunications Network (ATN) subnetworks transmits join and leave words to the CMU whenever a path to a specified ground address changes. The join event notifies the CMU that a new path to a specified ground address is available, triggering ATN air-to-ground communications.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal D. Understanding Protocol File Transfer to CMU via Williamsburg Data is transferred to the CMU using Williamsburg protocol. Williamsburg messages use the SAL of the equipment they are talking to as the label. In this case, the label is 304 as the sub-system identifier label sent from the HSD-440 to the CMU is 304. For more information, refer to "Understanding Word Format" on page F-7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal 4. Understanding LDUs and File Size BOP messages use Link Data Units (LDUs) encoded in binary octets to transmit data. LDUs conform to the following rules: • The data is transmitted from a source and is received by a sink. • LDUs consist of a set of contiguous ARINC 429 32 bit data words. • The initial data word of each LDU shall be a Start of Transmission (SOT) word.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal C. Understanding General Format Identifier (GFI) Definitions Table F-7 defines the GFI definitions. Table F-7 GFI Definitions To HSD-440 Mark 2 Terminal CMU File Type Label Destination Code Label Destination Code 304 M 307 (1) S Data 2 enveloped message GFI 1110b (Eh) A GFI of 1110 b indicates a data 2 Enveloped ACARS Message.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal A. Understanding the Full Binary Data Word This word shall transmit 5 nibbles of data. See ARINC 429P3 Attachment 11 for details. B. Understanding the Partial Binary Data Word This word shall transmit 4 or less nibbles of data. See ARINC 429P3 Attachment 11 for details. C. Understanding Protocol Words The protocol words are shown in Table F-9. The protocol identifier occupies bits 28-25 of the protocol word.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table F-9 Protocol Words and Uses (Continued) Protocol word Uses SYN The HSD-440 Mark 2 Terminal transmits a SYN word to inform the CMU that the construction of the last file that was transmitted is confused. The reception of a SYN word causes the CMU to abort any reception or transmission in progress. In addition, if the CMU was transmitting, it should re-initiate transmission of the file that was aborted.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table F-10 Data Types (Continued) Loop 0001b 16 Bit Loop Back Solo Word ID 16 Bit Data Filed E. Understanding Start of Transmission (SOT) When the HSD-440 Mark 2 Terminal receives a valid CTS with the destination code and word count of the previous RTS, then it responds by sending an SOT word immediately before the LDU. The SOT contains the file sequence number, the GFI, and the LDU sequence number.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 F-12 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX G: INTERNATIONAL ACCESS AND COUNTRY CODES Table G-1 shows a list of countries with their associated country codes and international access codes.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Cameroon 237 00 Canada 1 011 Cape Verde 238 0 Cayman Islands +1 (345) 011 Central African Republic 236 19 Chad 235 15 Chile 56 00 China 86 00 Colombia 57 009 Comoros 269 00 Congo (Brazzaville) 242 00 Congo (Kinshasa, formerly Zaire) 243 00 Cook Islands 682 00 Costa Rica
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code French Antilles 590 00 French Guiana 594 00 French Polynesia 689 00 Gabon 241 00 Gambia 220 00 Germany 49 00 Ghana 233 00 Gibraltar 350 00 Greece 30 00 Greenland 299 009 Grenada +1 (473) 011 Guam +1 (671) 011 Guatemala 502 00 Guinea 224 00 Guinea-Bissau 245 00 Guy
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Latvia 371 810 Lebanon 961 00 Lesotho 266 00 Liberia 231 00 Libya 218 00 Liechtenstein 423 00 Lithuania 370 00 Luxembourg 352 00 Macao 853 00 Macedonia 389 00 Madagascar 261 16 Malawi 265 101 Malaysia 60 00 Maldives 960 00 Mali 223 00 Malta 356 356 Marshall Isl
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Niger 227 00 Nigeria 234 009 Niue Island 683 00 North Korea 850 00 Northern Mariana Islands (Commonwealth of) +1 (670) 011 Norway 47 095 Oman 968 00 Pakistan 92 00 Palau 680 011 Palestine 970 00 Panama 507 00 Papua New Guinea 675 05 Paraguay 595 002 Peru 51 00 Philip
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Spain 34 00 Sri Lanka 94 00 St Helena and Tristan da Cunha 290 00 St Kitts +1 (869) 011 St Lucia +1 (758) 011 St Pierre and Miquelon 508 00 St Vincent +1 (784) 011 Sudan 249 00 Suriname 597 002 Swaziland 268 00 Sweden 46 00 Switzerland 41 00 Syria 963 00 Taiwan 886 00
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table G-1 International Access and Country Codes (Continued) Country Country Code International Access Code Vatican City +39, +379 00 Venezuela 58 00 Vietnam 84 00 Wallis and Futuna 681 19 Yemen 967 00 Yugoslavia (+38 discontinued) 99 Zambia 260 00 Zimbabwe 263 110 23-15-30 G-7 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 G-8 3 JUN 10
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal APPENDIX H: INMARSAT CAUSE CODES Table H-1 defines the maintenance port menu fault codes of the HSD-440 Mark 2 Terminal.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 1502 Handover, LES Ready, normal clear 1551 Call failed, LES congested (no channel) 1581 Call failed, service not provided at this LES 1591 Call failed, service temporarily not available at this LES 1592 Call cleared, credit card type not supported 1651 Call failed, LES congested (no channel terminal) 1661 Call fa
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 2021 MES int reject NCSA invalid CNO 2022 MES int reject NCSA failed qualification 2023 Call failed, Signal lost on NCSA during call setup, check antenna and try again 2024 Call failed, Missing channel assignment, try again 2025 Call failed, Signal lost on NCSC during call setup, check antenna and try again 2030 MES
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 2090 MES int reject ORR query invalid 2091 MES int reject ORR invalid 2092 MES int reject MES RR failed qualification 2093 MES int reject MES RR invalid CNO 2094 MES int reject NCRA missing 2095 MES int reject NCRA lost lock 2100 MES int reject illegal call type 2101 MES Int reject illegal peripheral 2102 Call
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8019 ACSE Finding Secondary Standalone Long 8020 ACSE Found Primary NCS 8021 ACSE Found Secondary NCS 8022 ACSE Found Primary Standalone 8023 ACSE Found Secondary Standalone 8024 ACSE found primary NGNCS 8025 ACSE found secondary NGNCS 8030 ACSE NSR Invalid 8040 ACSE Inert 8041 ACSE ODU Status 8080 ACSE NS
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8310 ACSE ORR Query Begin 8311 ACSE ORR Query Burst 8312 ACSE ORR Query Successful 8313 ACSE ORR Query Failed 8400 ACSE Fixed Begin 8401 ACSE Fixed MESRP 8402 ACSE Fixed Call Type Set 8410 ACSE Fixed Tune NCSA 8411 ACSE Fixed Channel Assignment 8420 ACSE Fixed Clearing Call 8421 ACSE Fixed Selective Clear
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 8583 ACSE Mobile Authentication End 8584 ACSE Mobile Power Control 8585 ACSE Mobile LES Connect 8586 ACSE Mobile Ringing Begin 8600 MPDS SCPC Mode Selected 8800 ACSE cable call begin 8801 ACSE cable call successful 8900 ACSE Logoff Begin 8901 ACSE Successful Logoff 8902 ACSE No ORR Logoff 9000 ACSE accepts
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 9101 Peripheral off hook 9102 Peripheral connected 9103 Peripheral ringing 9104 Peripheral ready 9105 Peripheral hanging up 9106 Peripheral hang up 9107 Peripheral not responding 9108 Peripheral dialing 9109 Peripheral abort dialing 9120 Peripheral DTMF accepted 9121 Peripheral DTMF rejected 9122 Periphe
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 400000 No call pending 400001 CT SP good 400002 CT SP full 400003 CT SP access denied 400080 CT SP find 400081 CT SP enumerate 400082 CT SP no entries 400090 CT SP delete 400100 CT SP spot beam selection 400105 CT SP MPDS 400110 CT SP ocean region registration 400111 CT SP ORR query 400112 CT SP log of
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 800404 Mobile data 800504 Mobile facsimile 800606 Mobile 64k UDI 800607 Mobile 56k UDI 800610 Mobile 64k audio 3k1 800622 Mobile Aero 64k UDI 800623 Mobile Aero 56k UDI 800625 Mobile Aero 64k audio 3k1 11A0 Call cleared, credit card not accepted 11D1 Call failed, Request data invalid 11D2 Call failed, insu
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 12C8 Handover failed, LES not detected 12D1 Call failed, Spot-beam data invalid 12D2 Call failed, invalid scrambling vector 15A1 Call failed, MES not authorized at this LES 15A2 Call failed, service not authorized at this LES 15A3 Call cleared, credit card not authorized 15A4 Call cleared, authentication reply inv
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 18B1 Call failed by NCS for unspecified reason 18B2 Call rejected, invalid service requested 18C1 NCS MES burst missing 18C3 NCS MES busy preemption failed 18D1 Call failed, invalid call request 18E1 NCS MES busy already 18E2 NCS MES busy already MPDS 1F01 Call cleared by terrestrial circuit (normal call termina
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition 90C0 ACSE transmit on 90C1 ACSE transmit off 90D0 ACSE spot beam handover started 90D1 ACSE spot beam termination timer started 90F0 Event log wiped B000 Mod error, general B001 Mod error, tune failed B002 Mod error, mode failed B003 Mod error, mmr failed B004 Mod error, not responding B010 MOD Invalid Mod
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B201 RF error RX VHF B202 RF error RX Lband B204 RF error RX VHF B208 RF error TX Lband B210 RF error RF error B220 RF error Ref error B27F Mod watchdog tripped B280 Generic voice codec errors B281 TMS spurious interrupt B300 Outdoor terminal failure, check connections to ODU B301 ODU error cannot set cabl
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Table H-1 Inmarsat Cause Code Definitions (Continued) Inmarsat Cause Code Code Definition B500 Battery charging communication failure B501 Power supply error B580 Battery is over temperature, charging disabled B581 Battery temperature is now ok, charging enabled C0010F Fixed 64k speech C00124 Fixed Aero 64k speech C00404 Fixed data C00504 Fixed facsimile C00606 Fixed 64k UDI C00607 Fixed 56k UDI
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion® HSD-440 Mark 2 Terminal Blank Page 23-15-30 H-16 3 JUN 10