eNfusion™ HSD-128 High-speed Data Terminal System Description, Installation, and Maintenance Manual This manual supercedes MN-1110-10023 and MN-1110-10057 and provides documentation for the equipment listed below.
PROPRIETARY STATEMENT This document contains information which is proprietary and confidential to SATCOM (EMS Technologies Canada, Ltd.). Neither this document nor the information contained within may be used for any purpose other than the purpose for which it was prepared. Neither this document nor the information contained within may be disclosed or copied without the prior written permission of EMS SATCOM. © 2006 EMS Technologies Canada, Ltd. All Rights Reserved.
CUSTOMER RESPONSE FORM To help us improve the quality of our product documentation, EMS SATCOM would appreciate your comments and suggestions on this publication. Please complete the following customer survey and send to EMS SATCOM at: EMS SATCOM 400 Maple Grove Road Ottawa, ON K2V 1B8 E-mail: techdocs@emssatcom.
Blank Page
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal SERVICE BULLETIN LIST Service Bulletin Number Subject Manual Rev. Manual Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Service Bulletin Number Subject Manual Rev. Manual Rev.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal RECORD OF REVISIONS When revisions are received, insert revised pages, record the date, and initial.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page RR–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal LIST OF EFFECTIVE PAGES * An asterisk indicates pages changed, added, or deleted by the current revision. F indicates a right foldout page with a blank back. Section Page Date Cover *ALL Nov. 3, 2006 Front Matter *ALL Nov. 3, 2006 Customer Comment Form *ALL Nov. 3, 2006 List of Effective Pages *ALL Nov. 3, 2006 Record of Revisions *ALL Nov. 3, 2006 Service Bulletin List *ALL Nov.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page LEP–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table of Contents INTRODUCTION 1. General .................................................................................................... TC-1 2. Abbreviations and Acronyms................................................................. TC-2 3. Advisories ................................................................................................ TC-4 4. Illustration of Equipment Covered..........
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (1) Stand-Alone Mode User Interfaces.............................................................. 1-28 (2) Collins Cooperative Mode User Interfaces .................................................. 1-28 (3) Honeywell Combined Mode User Interfaces ............................................... 1-28 (4) Selective Mode User Interfaces...................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (1) Overview........................................................................................................ 2-7 C. Configuring System Parameters using the Maintenance Port Utility................ 2-14 (1) Configuring System Parameters for Stand-Alone Mode ............................. 2-14 (2) Configuring System Parameters for Cooperative Mode .............................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal C. Cable Shielding and Termination........................................................................ 3-5 6. ARINC 600 Trays and Connectors............................................................. 3-7 A. Installation Kits ................................................................................................... 3-7 B. Cabling Notes ..........................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (1) General Overview.......................................................................................... 4-3 (2) Connection Requirements ............................................................................. 4-4 (3) Accessing the Maintenance Utility Program .................................................. 4-7 (4) Using the HSD Maintenance Utility Program........................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal C. Troubleshooting Aids........................................................................................ 4-81 (1) Fault Isolation Screen Displays ................................................................... 4-81 (2) Troubleshooting Table ................................................................................. 4-93 D. Fault Isolation and Diagnostic Procedures............................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal List of Figures Figure TC–1. HSD-128 Terminal .............................................................................................. TC-5 Figure TC–2. HSD-X SATCOM High-Speed-Data Transceiver Extension ............................... TC-6 Figure 1–1. Forward ID Assignment (3-channel system) .......................................................... 1-25 Figure 1–2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–13. Forward ID, Hex to Binary Conversion – Cooperative Mode................................ 3-47 Figure 3–14. HSD Remote LED Panel Circuit – Cooperative Mode.......................................... 3-48 Figure 3–15. RJ-45 Connector Terminator Details – Cooperative Mode................................... 3-50 Figure 3–16. User Data I/O Mode Configurations – Cooperative Mode ........................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 4–3. Front Panel Access, Maintenance Cable (HSD) ...................................................... 4-6 Figure 4–4. HSD-X Front-Panel, Maintenance Port Cable .......................................................... 4-7 Figure 4–5. Level 1 MENU Selections ......................................................................................... 4-9 Figure 4–6. Level 2: Menu 1 .....................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 4–38. Call Initialization (Aero H/H+ call) ......................................................................... 4-65 Figure 4–39. Stable Connection with one Aero H/H+ call.......................................................... 4-65 Figure 4–40. Connection with two Aero H/H+ calls ................................................................... 4-65 Figure 4–41.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal List of Tables Table 1–1. Supported Services Matrix for HSD-128, HSD-64, and HSD-X................................... 1 Table 1–2. HSD Transceiver Variants ........................................................................................... 3 Table 1–3. Equipment Covered ..................................................................................................... 4 Table 1–4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–3. RF Parameters Definition........................................................................................... 13 Table 3–4. WOW Pin Wiring Table .............................................................................................. 14 Table 3–5. RJ45 Wiring Details – Stand-Alone............................................................................ 18 Table 3–6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–38. Data I/O Mode Pin Strapping – Multi-Channel......................................................... 71 Table 3–39. HSD-128 Multi-Channel Configuration ARINC 600 Top Plug Connections ............. 73 Table 3–40. HSD-128 Multi-Channel Configuration, ARINC 600 Middle Plug Connections........ 75 Table 3–41. HSD-128 Multi-Channel Configuration ARINC 600 Bottom Plug Connections........ 77 Table 3–42.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation......................................................................... 94 Table 4–28. Modification History................................................................................................
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal INTRODUCTION 1. General This manual provides all the specifications, principles of operation, and information necessary to install an HSD High-Speed-Data SATCOM Transceiver made by EMS Technologies in all supported operational modes and configurations.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal ms Millisecond MSN Multiple Subscriber Number NAT Network Address Translation OCXO Oven Controlled Crystal Oscillator OEM Original Equipment Manufacturer O&I Outline and Installation Drawing PC Personal Computer (or Laptop) PN Part Number PPPoE Point-to-Point Protocol over Ethernet REA Responsible Engineering Authority RF Radio Frequency RFI Radio Frequency Interference RFU Radio Fre
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Advisories WARNING: SERVICE PERSONNEL MUST OBEY STANDARD SAFETY PRECAUTIONS, SUCH AS WEARING SAFETY GLASSES, TO PREVENT PERSONAL INJURY WHILE INSTALLING OR PERFORMING SERVICE ON THIS UNIT. WARNING: ASSOCIATED SATCOM EQUIPMENT RADIATES HIGH FREQUENCY RADIATION AND POSES A RADIATION HAZARD OF 1.6 GHZ.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Illustration of Equipment Covered Figure TC–1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure TC–2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal SYSTEM DESCRIPTION 1. Purpose of Equipment The HSD is a scalable, high-speed-data, satellite communications terminal, which interfaces with an ARINC 741-compatible antenna subsystem to provide a high-speed data communication link with the Inmarsat satellite communication network.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. Equipment Covered A. Hardware Description Table 1–2 provides a comparison of the Hardware variants of HSD and HSD-X transceivers. Table 1–3 lists and describes all models of HSD transceivers covered in this manual. Table 1–2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–3. Equipment Covered Model HSD-128 Description PN 1110-A-0150 HSD High-speed Data SATCOM Transceiver: High-speed data terminal containing two channel cards, a control processor, a Data I/O Type 2 card, a high power amplifier, and a 115 V ac, 400 hertz (Hz) power supply.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (2) Operational Software Part Numbers Table 1–4 provides a list of software part numbers for the HSD transceiver. Table 1– 5 provides a list of software part numbers for the HSD-X transceiver. Table 1–4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (b) Combined Mode For Combined Mode installations, the minimum requirement for HSD Control-Processor software is version 5.4 (or later) to use ARINC 429 data from the Honeywell SDU. Version 5.4, Control-Card software is available via HSD Service Bulletin, 1110-SB-0012. The minimum requirements and recommendations for software are shown in Table 1–7. Table 1–7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–9. Selective Mode Minimum Software Requirements Unit Part Number Software PN Minimum Software Recommended Software Type Software Req’t 5.7 HSD-128 1110-A-0001 1110-A-0048 Control Processor 1110-A-0060 1110-A-0150 1110-A-0082 Channel Card 1110-A-0160 C35 7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–12 provides a service bulletin matrix to list the applicability of all service bulletins released against the HSD and HSD-X units as of the release date of this manual. Table 1–11. Description of Control Processor Software Changes Control Processor Software Version Applicable Service Bulletin Compliance Requirements Description of Change 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–11. Description of Control Processor Software Changes Control Processor Software Version Applicable Service Bulletin Compliance Requirements Description of Change 5.7 1110-SB-0011 Recommended for all units operating in Cooperative Mode with Collins Sat-906 systems, optional for all other units.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–11. Description of Control Processor Software Changes Control Processor Software Version 7.0 Applicable Service Bulletin Compliance Requirements 1110-SB-0012 Recommended for units operating in multi-channel configurations with HSD transceivers. Optional for all other units and system modes. Description of Change Upgrades the channel card software to version C41 (6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal PN 1110-A-0401 PN 1110-A-0160 PN 1110-A-0150 PN 1110-A-0080 PN 1110-A-0070 PN 1110-A-0060 Service Bulletin PN 1110-A-0001 Table 1–12.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal PN 1110-A-0160 PN 1110-A-0401 PN 1110-A-0150 PN 1110-A-0080 PN 1110-A-0070 PN 1110-A-0060 1110-SB-0014 X X X X X X Upgrades Data I/O Type 2 software to fix susceptibility to certain malformed traffic, which caused PPPoE sessions to “hang-up” leaving the call connected 1110-SB-0015 X X X X X X Upgrades control processor software to enhance Cooperative Mode operation (Version 7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Equipment Description This section describes the physical and environmental specifications of the equipment. A. Applicable Documents • High speed data terminal Setup Guide, EMS SATCOM PN MN-1110-10048 • ARINC 741. ARINC Report 413A – Guidance for Aircraft Electrical Power Utilization and Transient Protection, Attachment 3-2, Wire Shielding and Grounding Requirements and Appendix 7 B.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–13. HSD Equipment Characteristics and Specifications CHARACTERISTIC SPECIFICATION HSD-128 dc input power 1110-A-0001, 1110-A-0160 Voltage Minimum: 22 V dc Typical: 27.5 V dc Maximum: 30.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–13.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–14.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–15. HSD-X Transceiver Specifications CHARACTERISTIC SPECIFICATION Transceiver output impedance 50 ohms VSWR 2:1 maximum Input level operational Input level no damage -107 dBm to -47 dBm +10 dBm External (Digital) Interfaces Crosstalk Bus ARINC 429 high-speed (100 kbps) data bus Maintenance Port RS-232 Data loader Front and Rear Connector RS-232 serial bus supporting 57.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 1–16. HSD-X RTCA/DO-160D Environmental Specifications CHARACTERISTIC SPECIFICATION Emission of RF Energy Category M Lightning Induced Transient Susceptibility Category A3E3 Lightning Direct Effects Category X Icing Category X Electrostatic Discharge Category A D. Mechanical Description This section describes the mechanical characteristics of the HSD and HSD-X transceivers.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The rear connector complies with ARINC 600, shell size 1. The connector top and middle cavities have 60 number 22 interconnects, while the bottom cavity has two number 16 interconnects, one number 12 interconnect, and two RF interconnects. E. Electrical Description This section describes the external electrical interfaces of the HSD and HSD-X transceivers.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The HSD-128 is the master of the system; it controls the overall operation of the Multi-Channel HSD configuration. It keeps track of time and allocated power and may command the HSD-X units to terminate calls under certain conditions, such as an ocean region change. The HSD-X units are wired to the HSD-128 HPA and therefore compete equally for HPA power allocation.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The 24-bit Fwd ID strap pins, available on the ARINC 600 connector, form part of the Inmarsat serial number (ISN). The ISN consists of the type approval number and the Fwd ID address. Each FRLP is associated with Inmarsat Mobile Numbers (IMN), which are the numbers that a user dials from the ground to reach the terminal on an aircraft. There is a unique IMN for each of the service types (e.g.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (e) HSD Antenna Interface 1. Stand-Alone Mode and Multi-Channel Configuration In Stand-Alone installations, the HSD interfaces to any mechanically steered, conformal-array, or phased array, ARINC 741-compatible, antenna subsystems.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (j) • HPA fault • External Reference Fault • Internal ROM Fault • Internal RAM Fault • Over Temperature Fault HSD Remote Reset The remote reset output provides an external reset function for the complete HSD system. Pressing the momentary “normally open” (N.O.) switch resets the system’s processor-card circuitry.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The 24-bit Forward ID strap pins, available on the ARINC 600 connector, form part of the Inmarsat serial number (ISN). The ISN consists of the type approval number and the Fwd ID address. Each Forward ID is associated with Inmarsat Mobile Numbers (IMN), which are the numbers that a user would dial from the ground to reach the terminal on an aircraft. There is a unique IMN for each of the service types (e.g.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (d) RS-232 Maintenance Port Like the HSD-128, HSD-X units have an RS-232 Maintenance Port interface that provides access to a maintenance utility program for system monitoring and testing purposes. Access to the maintenance port and the HSD Maintenance Utility Program is possible using an RS-232, VT-100 terminal (PC or Laptop operating a terminal emulation program such as HyperTerminal).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (e) HSD-X Remote Status Panel (Optional) The outputs to the optional “Remote Status Panel” provide a visual indication of the operational status of the HSD-X. They “mirror” the unit’s front panel LEDs labeled as Power (LED1), Fault (LED2), and Channel Available (LED3). Table 1–20 defines the interpretation for each LED. Refer to "Installation" on page 3-1 for detailed installation and circuit requirements.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 1–4 and Figure 1–5 illustrate the user interfaces for single-channel HSD transceiversFigure 1–6 and Figure 1–7 illustrate the user interfaces for dual-channel HSD transceivers. For clarity, these figures only display Data Services.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Each channel provides an ISDN 64 kbps connection that can be used for voice or data services. The two channels in the HSD can be internally bonded to provide a 128 kbps ISDN data connection. Externally, all four channels shown in Figure 1–10 can be combined to provide a single 256 kbps capability with the help of a router, Ethernet hub, or Terminal Adapter.
RS-232 10BT ISDN S/T RS-232 ARINC Connector ISDN S/T Data I/O Processor Channel Card SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal ISDN S/T Terminal Adapter Serial or USB Laptop computer HSD Transceiver Figure 1–5.
ISDN S/T RS-232 Channel Card 10BT ISDN S/T RS-232 ARINC Connector RS-232 Channel Card Data I/O Processor SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal ISDN S/T Terminal Adapter Serial or USB ISDN S/T HSD Transceiver Laptop computer Figure 1–7. Reduced Functionality Dual-Channel System (6) ISDN Circuit-Switched Data Interface HSD and HSD-X transceivers connect to a variety of interface options.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Note: Activating MPDS on a particular channel card temporarily, disables the ISDN port on that channel card while MPDS service is in-use. For connection to Inmarsat Mobile ISDN services, install an RJ-45 interface connector in the cabin area. "Installation" on page 3-1 describes the RJ45 connector and cable termination.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Parity – none • Stop bits – 1 • Flow control – Hardware Refer to the applicable Interconnect Diagrams provided in "Installation" on page 3-1 for complete pinout designations. (8) Ethernet Data Interface HSD transceivers PN 1110-A-0150 and 1110-A-0160 support the Ethernet interface.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal A standard VT100 compatible terminal or computer (PC/laptop) running an emulator program such as HyperTerminal©, ProComm (PCPLUS)©, or another serial communication package provides the user interface to the HSD maintenance utility program.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Inmarsat System Overview A. General This section provides an overview of the Inmarsat satellite communications system and networks. B. Satellite Network Overview The satellite communication system (SATCOM) comprises global satellite networks, Land Earth Stations (LES), and Mobile Earth Stations (MES).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 1–9.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. HSD Modes and Configuration Descriptions A. General This section describes the system mode and configuration variations for the HSD High-Speed-Data SATCOM Transceiver installations. B. Overview HSD transceivers install in a variety of customized configuration modes. HSD transceivers may be installed as Stand-Alone systems or as Non-Stand-Alone units installed within existing SATCOM systems.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The user has the option to select the service type needed—either circuit-switched data (Swift64 Mobile ISDN) or MPDS. The HSD also supports three or more simultaneous voice or 14.4 kbps fax calls when not being used in data mode— depending on the number of additional HSD-X transceivers installed.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal configured as a single-channel system. Use the HSD maintenance utility program to configure the EEPROM settings for a single channel card. (Menu 3, press M, select miscellaneous parameter number 10.) Refer to the system block diagram in Figure 1–12 for Cooperative Mode system details. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (c) Multi-Channel Configurations The HSD Multi-Channel configuration combines a dual-channel, Stand-Alone Mode HSD-128 Transceiver with one or more single-channel HSD-X transceivers to add additional channels to the system. Each channel provides an ISDN 64 kbps connection that can be used for voice or data services.
LEGEND ACU Power/Control & BITE RF Signals Multi-Control ACU BITE/HPA Mute Power/Control & BITE HPA (60W) ARINC 429 Multi-Control OUT Multi-Control IN RS232 65 dB Gain Combiner RX ISDN (2) MPDS Bond (RS422) ISDN Telephone Terminal Adapter Splitter Channel Card 2 TX ISDN (2) TX HSD TRANSCEIVER Terminal Adapter ISDN (1) MPDS ISDN Telephone Channel Card 1 RX Oscillator 10 Mhz Data I/O Card Power Supply 28 V dc or 115 V ac, 400 Hz Control Card RS232 RS232 RS232 OCXO Ready
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 1–12.
LEGEND RF Signals 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal C. Functional System Theory The HSD is a high-speed SATCOM Transceiver that contains: either one or two channel cards, a high stability reference oscillator, a high power amplifier, a data processor module, and a power supply. The HSD receives power from the aircraft as either 28 V dc or 115 V ac, 400 Hz.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2 Wire Fax (Group 3) 2 Wire Fax (Group 4) ISDN BRI S/T Telephone RS-232 TA Laptop computer ISDN BRI S/T 10BT / USB 10BT RS-232 or ISDN BRI S/T Hub (10BT, USB) Router Laptop computer RS-232 or ISDN BRI S/T 10BT RS-232, ISDN BRI S/T, or Ethernet 10Base T (with Data I/O Type 2) 10BT / USB Hub (10BT, USB) Laptop computer Server Telephone 2 Wire 10-100 Base T EMS CNX Network Module (EMS PN 1110-A-
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page 1–46 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal SYSTEM OPERATION 1. Introduction This section provides basic information on registering, commissioning, and operating the HSD High-Speed Data SATCOM transceiver and HSD-X High-Speed SATCOM Extension transceiver. For more information on Swift64 service providers and the activation of HSD and HSD-X transceivers, visit the EMS Technologies HSD Web page at www.emssatcom.com/hsd/team.asp.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. Activating HSD Transceivers To activate an HSD or HSD-X transceiver: 1. Obtain terminal information (Forward Identification Numbers and Terminal Type and Category information) from EMS Technologies. 2. Register the terminal with an Inmarsat approved service provider and activate an account. A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (1) Swift64 Service Categories Inmarsat has restricted the frequencies assigned to the HSD system eliminating the possibility of intermodulation signals occurring, thus avoiding any resulting interference problems with the GPS band signals. Inmarsat split the band of frequencies assigned to Swift64 High-Speed Data into two separate categories: Category A and Category B.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal SAT-906 series SATCOM. It is recommended that all systems operating in Selective Mode be upgraded to support Combined or Cooperative Mode as applicable. B. Selecting a Service Provider Register the HSD transceiver with an Inmarsat service provider.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Configuring HSD Systems This section provides basic information on how to configure HSD systems for operation with user devices. A. Setting up Networks This section provides basic information on how to configure user connections and networks for operation with the HSD and HSD-X transceivers and satellite communications network.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (2) Networking Components The network configurations illustrated in Figure 2–1 have common components that integrate and operate with HSD transceivers.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Connect to the HSD transceiver’s Ethernet interface either directly from a dedicated Ethernet card using an Ethernet crossover cable or from a hub using a regular Ethernet cable. B. Mapping User Devices for ISDN Services This section describes how the HSD system manages ISDN traffic for user devices connected to the network.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal For a one-channel HSD transceiver: one IMN is assigned to 64 kbps Speech, 56 kbps Data, and 3.1 kHz Audio; three IMNs are assigned to 64 kbps Data; and sixteen IMNs are assigned to 4.8 kbps LSV. For a two-channel HSD transceiver: two IMNs are assigned to 64 kbps Speech, 56 kbps Data, and 3.1 kHz Audio; six IMNs are assigned to 64 kbps Data; and in Stand-Alone systems thirty-two IMNs are assigned to 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 2–2. System Setup and Mapping for Incoming Calls (Fixed-to-Mobile) Note: Refer to Table 2–2, Table 2–3, and Table 2–4 for the default MSNs assigned within the HSD system. Table 2–2. IMN and MSN Assignments for ISDN Bus #1 Channel Card # 1 Forward ID XAXXXX Service Type IMN MSN 64 kbps Speech 60xxxxxx1 (See Note below) MSN 40 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–3. IMN and MSN Assignments for ISDN Bus #2 Channel Card # 2 (if installed) Forward ID XBXXXX MSN 10 MSN 11 MSN 12 64 kbps Data 60xxxxx26 60xxxxx27 60xxxxx28 4.8 kbps LSV 76xxxxx29 through to 760xxxx44 MSN 80 through to 95 Note: IMNs shown are examples only. Actual IMNs may not be assigned in numerical sequence. HSD-X extension channels are assigned IMNs using the same logic.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal T1 and T2 are two-digit identifiers for Inmarsat service types. X1 to X7 can be any digit between "0" and "9". The IMNs for Mini-M (4.8 kbps LSV) service type are identified by the T1 and T2 numbers 7 and 6. The IMNs for the 56 kbps and 64 kbps service types (including ISDN Speech and 3.1 kHz audio) are identified by the T1 and T2 numbers 6 and 0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–4. HSD Transceiver MSN Configuration Table Forward ID Service Type IMN MSN Channel Card #1 (XAXXXX) 64 kbps Speech 60xxxxxxx 40 Channel Card #2 (XBXXXX) Dual Channel Units 64 kbps Speech 60xxxxxxx 40 Channel Card #3 (XCXXXX) Multi-Channel HSD-X 1 64 kbps Speech 60xxxxxxx 40 Channel Card #4 (XDXXXX) Multi-Channel HSD-X 2 64 kbps Speech 60xxxxxxx 40 Channel Card #1 (XAXXXX) 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–4. HSD Transceiver MSN Configuration Table Forward ID Service Type IMN MSN Channel Card #3 (XCXXXX) Multi-Channel HSD-X 1 4.8 kbps LSV 76xxxxxxx (Not supported in Non-Stand-Alone systems) 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95 Channel Card #4 (XDXXXX) Multi-Channel HSD-X 2 76xxxxxxx 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–5. System Assignments for Incoming Calls (Fixed-to-Mobile) Entry PERIPH MSN TID Call Type REDIR 20 ISDN 84 5 800103 Mobile AMBE (4.8 kbps LSV) 21 ISDN 85 6 800103 Mobile AMBE (4.8 kbps LSV) 22 ISDN 86 7 800103 Mobile AMBE (4.8 kbps LSV) 23 ISDN 87 8 800103 Mobile AMBE (4.8 kbps LSV) 24 ISDN 88 9 800103 Mobile AMBE (4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Type the password maint. (The password does not appear on the screen.) The HSD Maintenance Port Utility Program Menu 1 appears. You are now ready to begin configuring the system parameters for Stand-Alone operation as described in the following sections. (a) Configuring the Terminal Category for Stand-Alone Mode The factory default for the Terminal Category is configured to “2=HW Strapping.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (2) Configuring System Parameters for Cooperative Mode This section describes how to use the HSD Maintenance Port Utility to configure the HSD system parameters for operation in Cooperative Mode. Refer to "Test and Fault Isolation" on page 4-1 for detailed instructions on how to connect to and use the HSD Maintenance Port Utility Program.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal TERMINAL CATEGORY HW STRAPPED VALUE 0=SAT906 1=STANDALONE 2=HW STRAPPING 3=MCS3000 4=MCS6000 5=MCS7000 6=MCS COMB 7=STANDALONE W/O ANTENNA 8=HCM COMBINED 9=COOPERATIVE ROCKWELL-COLLINS SAT906 10=OLD COMBINED MODE DEVELOP 11=HSD-X NETWORK 12=HSD-X NETWORK W/O ANTENNA 13=VIPER NEW TERMINAL CATEGORY = ? 9 3. Type 9 for Cooperative Rockwell-Collins SAT-906 and then press Enter.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (a) Step One: Honeywell System Configuration Using the Honeywell SATCOM Direct CMT, obtain the antenna loss parameter and configure the High Rate Data Support settings. The connection to the Honeywell SATCOM Direct CMT Port uses an RS-232 interface with any “VT-100” terminal emulator program. Configure your VT-100 terminal settings as follows: 9600 bps, no parity, 8 data bits, and 1 stop bit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1. Configuring the Terminal Category for Combined Mode If the HSD transceiver does not have the recommended hardware strapping for system configuration installed, configure the terminal category using the HSD Maintenance Port EEPROM parameters as described in the following procedure. To configure the Terminal Category: 1. In Menu 3, to select misc. EEPROM parameters press M.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU 3 FIRMWARE Vx.x L list EEPROM S list event log M misc.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MISCELLANEOUS PARAMETERS 1 HPA-TO-ANTENNA TOTAL LOSS 2 FORWARD ID 3 GPS PROTECTION ALGORITHMS 4 REGISTRATION REQ'D BEFORE CALLS 10 NUMBER OF CHANNEL CARDS WHICH PARAMETER # 11 14 15 16 17 FRONT PANEL LEDS ENABLED MAINTENANCE PORT INVERSE VIDEO MAINTENANCE PORT DEGREES SYMBOL TERMINAL CATEGORY VIPER ANTENNA GAIN N for next page 18 VIPER HPA/ANT LOSS 24 RECEIVER CALIBRATION 28 RX32 ACTIVE 29 DEFAULT
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The HSD Maintenance Port Utility Program menus appear. You are now ready to begin configuring the system parameters for Selective Mode operation as described in the following procedure.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (5) Configuring System Parameters for Multi-Channel Configurations This section describes how to use the HSD Maintenance Port Utility to configure the HSD system parameters for operation in Multi-Channel Configurations. Refer to "Test and Fault Isolation" on page 4-1 for detailed instructions on how to connect to and use the HSD Maintenance Port Utility Program.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal TERMINAL CATEGORY HW STRAPPED VALUE 0=SAT906 1=STANDALONE 2=HW STRAPPING 3=MCS3000 4=MCS6000 5=MCS7000 6=MCS COMB 7=STANDALONE W/O ANTENNA 8=HCM COMBINED 9=COOPERATIVE ROCKWELL-COLLINS SAT906 10=OLD COMBINED MODE DEVELOP 11=HSD-X NETWORK 12=HSD-X NETWORK W/O ANTENNA 13=VIPER NEW TERMINAL CATEGORY = ? 11 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal secondary LES value in their systems. However, a valid Secondary LES Access Code must be entered in the HSD system. The Secondary LES Access Code must be the same as the Primary LES Access Code. When operating HSD software version 5.7, DO NOT select the “Send line ends with line feeds” option in the terminal emulation program’s ASCII Setup. (See example dialog box presented in Figure 2–3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (d) Changing LES access codes on a call-by-call basis The following procedure provides detailed instructions in how to change the LES default access code for HSD and HSD-X transceivers. Note: This procedure provides instructions on how to change the HSD system default for LES selection.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MISCELLANEOUS PARAMETERS 1 HPA-ANTENNA CABLE LOSS 2 FORWARD ID 3 AORW LES ACCESS CODE 4 TERRESTRIAL NETWORK ID 5 HPA-CHANNEL CARD CABLE LOSS 6 MAX HPA GAIN 7 MIN ANTENNA GAIN 8 MAX EIRP 9 MAX CHANNEL_CARD POWER 10 NUMBER OF CHANNEL CARDS 11 FRONT PANEL LEDS ENABLED 12 RX ATTENUATION (LAND-ON-WINGS) 13 MIN SECS BETWEEN CHAN CARD RESETS 14 MAINTENANCE PORT INVERSE VIDEO 15 MAINTENANCE PORT DEGREES SYMBOL 16 TE
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal EEPROM LISTING: MAGIC NUMBER :OK EEPROM VERSION NUMBER 2001 FIRMWARE VERSION 1018 SERIAL NUMBER: 114 IGNORED FAULTS: 0 HARDWARE CONFIG: 0 NUMBER OF POWERUPS (index 0) 13 HOURS OF OPERATION (index 0) 49 MISCELLANEOUS PARAMETERS HIT 'L' for MORE MISCELLANEOUS PARAMETERS HIT 'L' for MORE HPA-ANTENNA CABLE LOSS: 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1. Connect to the HSD-128 Maintenance Port. 2. Type the password maint 3. In Menu 3, press P. 4. Follow the application prompts and enter the LES access codes for each Ocean Region as provided by your service provider. A valid LES ID (LES Access Code) must be entered for all Ocean Regions.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Press the reset or remote reset button on all HSD and HSD-X units installed in the system. (Not supported in Cooperative or Combined Mode systems.) When the “reset” or “restart” is completed, the configuration values and parameters are activated. Note: In Multi-Channel configurations, the application prompts the user to select the specific units to reset as shown in the example screen below.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The ORT Tool allows users to customize certain user-defined parameters in the HSD system such as: • Satellite Data • Service Provider Information • LES Access Code selection • Ethernet Configuration parameters (including IP Address information) • Cable loss The HSD ORT Tool has built-in help files that describe in detail the functionality of the tool.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. In the Part Numbers text boxes, type in a Customer PN (required) and Table PN (optional – default is ORT Table). Note: The Part Numbers are used to identify the ORT configuration file. The Customer PN is a required field because of ARINC Data Loader file requirements.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. In the satellite-location-information text boxes (Ocean Region, Index, Location, and Mnemonic), modify the data for a satellite (AORE, AORW, IOR, and POR) as required. Note: In the Index text box, type in a unique number from 0 to 7. This index value references the selected satellite entry’s position with the unit’s tables. 5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Click Remove to delete selected satellite entries from the satellite list field. • Click Update to change the data values of a satellite selected from the existing list (the selected satellite appears highlighted). Note: If the required data fields are not completed correctly, an error message appears indicating incomplete or incorrect field entries.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 13. Click the PPPoE tab. The PPPoE property sheet appears. 14. In the AC-Name text box (Access Concentrator Name), type the name of the Access Concentrator used by the PPPoE client to differentiate between multiple PPPoE devices.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–7. DATA I/O Naming Convention for AC-Name HSD AC-Name HSD-X #1 DataIO (default) DataIO-1 HSD-X #2 DataIO-2 15. Select or clear the LCP Filtering and Allow MPDS as default service check boxes as required. 16. In the Accessible through PPPoE field, select the appropriate service option (MPDS and ISDN, MPDS Only, None-disable, or ISDN Only). 17. Click OK.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (2) Saving the ORT file To save the ORT file: 1. Click Save. A Save as dialog box appears. Note: Save a copy of the configuration file for back up and future reference. 2. In the File name text box, type the name of the configuration file. 3. Click Save. You return to the main screen of the HSD ORT Tool. (3) Loading the ORT To create a disk to load the ORT: 1. Click Make Disk.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–8. Description of Select Contents Dialog Box Options Option Description Selecting the HSD-X option creates an ORT file for HSD-X transceivers. The format of the basic file is HSDX.ORT. The format for a self-loading file is HSDXORT.exe. Selecting the HSD option creates an ORT file for HSD transceivers. The format of basic file is HSD.ORT. The format of a self-loading file is HSDORT.exe.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (a) Loading Self-loading ORT Files Self-loading ORT files have the HSD software load application embedded in the file. Self-loading ORT files are executable. Opening the file executes the software load application. To load self-loading ORT configuration files onto an HSD or HSD-X unit: 1. Remove power from the system. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. Close all other applications running on the computer (especially programs that use the serial COM port, e.g. HyperTerminal). The load program may not execute successfully if other programs are running. 6. Start the HSD Software Load program (ADT_LOAD.exe) to launch the load program. A DOS window opens displaying the “Load Target” menu; it shows a number of load selection options. HSD/HST LOADER Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal HSD/HST LOADER Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Using the HSD System This section describes how to place voice and fax calls using the ISDN interface of the HSD SATCOM system. A. Placing Voice and Fax Calls Placing voice and fax calls using the HSD system are similar to placing an international telephone call or entering a telephone number for dial-up networking data calls.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • # (SEND): Pressing # (or entering # at the phone number field on data devices) signals the system to “send” the call. Certain devices using the HSD system may not have the functionality to insert the # symbol at the end of the dialing sequence. For those devices, additional Dial Code Prefixes are required to override the “send” command requirement. Refer to Table 2–10 for more information.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 2–10. Dial Code Prefixes for System Overrides Reason for Override Dial Code prefix Example Dialing Sequence Use this Dial Code Prefix to 901 + LES override the default LES CODE configured in the system. This Dial Code Prefix signals the system to override the default LES and use the selected LES instead. (See Table 2–6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal If SNAC is unsupported, use the Ocean Regions Number that the aircraft (based on its projected flight path) is probably logged on to. If the call fails to connect to the aircraft, re-try the call using an alternate Ocean Region Number. Figure 2–5 illustrates the Mobile-to-Mobile dialing sequence. Figure 2–5. Mobile-to-Mobile Dialing Sequence B.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Because of these challenges, it is sometimes necessary to optimize the system to achieve peak performance over the satellite network. ISDN protocols are not designed specifically for use over satellite communication networks. To improve data transfer rates most ISDN protocols require minor adjustments. For best results, consider how the ISDN protocol you intend to use sends data over the network.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1. Terminal Adapters—ISDN Modem Terminal adapters are ISDN devices that function similarly to a modem; they dial and answer calls, and receive and transmit data. They are also referred to as TA’s, ISDN cards, or ISDN modems. Note: The HSD works with Euro S/T ISDN terminal adapters. Inmarsat Swift64 Mobile ISDN service and the HSD do not support the North American ISDN variant. 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • An RS-232 cable (Asynchronous Serial) • An activated account with an Inmarsat Service Provider that supports MPDS services • A computer with an available COM port • Dial-up Networking capabilities When operating MPDS over the RS-232 port, no external connecting devices are required. The channel card in the HSD acts as a “modem” and responds to modem “AT” commands.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Disable the read receipt option • Send messages in text format not in HTML format and disable signatures to reduce message size • Disable the “automatic download of message when in viewing panel” feature • Increase the time period for automatic mail checks to reduce traffic • Use IMAP4 mail protocol to allow for header retrieval only Note: Disable the “Save copy of send messages in the ‘Sent Items
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The following is an example of a configuration for bonded calls using a DIVA T/A for illustration purposes only. Other manufacturers’ terminal adapters may require different or more complex configurations to configure the system for bonded calls. 1. Using HyperTerminal, connect to the Terminal Adapter EURO ISDN modem. 2. Type AT@MENU. The following screen appears. 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. When prompted, select “yes” to save the profile and then reboot your computer. 5. Using the AT@ MENU command, confirm the settings are correct. The Terminal Adapter is now configured to place bonded Multilink calls.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Note: If you are dialing a North American ISDN number, both Service Profile Identifier ISDN (SPID) numbers must be included in the dial-up networking connection to place Multilink calls. To configure the dial-up connection to include both SPID numbers, type in both numbers separated by the “&” symbol. The following screen illustrates the configuration of a Multilink connection to a North American number.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (b) Bonding Channel Cards using the Ethernet Interface for Mobile ISDN Service HSD transceivers with a Data I/O Type 2 Card (PNs 1110-A-0150, 1110-A-0160 and HSD transceivers with service bulletin 1110-SB-0004 accomplished) support the bonding of two channel cards using the HSD Ethernet interface to access Swift64 Mobile ISDN.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal To access Swift64 Mobile ISDN services over the Ethernet interface using a bonded two-channel-card connection 1. Create a new dial-up networking connection for two-channel Ethernet ISDN. 2. Double-click on the connection and select properties. The PPPoE Properties Dialog box appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. From the Connect using list, select both available ISDN channels. 4. Select All devices call the same number. 5. Click Configure. The ISDN Configure dialog box appears. 6. Select 64K Digital as the Line type. 7. Select Negotiate line type. 8. Click OK.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 9. Click on the Options tab. The Options tab sheet appears. 10. From the Multiple Devices list select Dial all devices and then click OK. (Display progress while connecting and Prompt for name and password, certificate, etc, and Redialing options are optional.) 11. Click the Security tab. 12. In Security options, select Typical recommended settings and Allow unsecured password. 13. Click OK.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 14. Click the Networking tab. The Networking tab sheet appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 15. Select the Internet Protocol TCP/IP. 16. Click Properties. The Internet Protocol dialog box appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 17. Select “Obtain an IP address automatically” and “Obtain DNS address automatically”, and then click OK. This completes the creation of the new bonded connection for Mobile ISDN using the Ethernet interface. Before using the connection, you need to configure the Local Area Connection properties.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal To Configure the Local Area Connection Properties for Bonding (PPPoE): 1. In Network and Dial-up Connections, double-click on Local Area Connection. The Local Area Connection Status dialog box appears. 2. Click Properties. The Local Area Connection Properties dialog box appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Select PPP over Ethernet Protocol and then click Properties. The PPP over Ethernet Protocol Properties dialog box appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. On the General tab sheet, select “2” for the Number of lines (WAN endpoints). This completes the connection configuration for the two-channel Swift64 Mobile ISDN over Ethernet connection. The connection is ready to use.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Page 2–64 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal INSTALLATION 1. Introduction This section provides general information and procedures required to install HSD transceivers and HSD-X transceivers in Multi-Channel configurations on an aircraft. Mode-specific installation instructions are provided in separate installation sections.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. Advisories Before performing any installation procedures, read the safety advisories listed in "Introduction" on page TC-1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Pre-Installation Inspection Before installing any HSD equipment, conduct a pre-installation inspection of all parts to ensure that no damage occurred during transit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Unpacking and Inspecting Equipment • Unpack the HSD/HSD-X transceiver(s) from their shipping containers. • Verify that the part number displayed on the shipping box and equipment component matches the model and part number ordered. If components are missing from the shipment, contact EMS Technologies immediately and report the problem. • Visually inspect the unit for any shipping damage.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. Cabling and Connector Requirements This section provides general electrical installation information on power, ground, shielding requirements, and cabling that applies to all installation modes for HSD and HSD-X transceivers. A. Power Requirements The aircraft power supply provides power to the HSD transceiver.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 6. ARINC 600 Trays and Connectors This section provides detailed information on the ARINC 600 trays provided in the HSD Installation Kits that are used in the installation of the HSD and HSD-X transceivers. The HSD LRU is installed in a standard, ARINC 600, 8-MCU tray. Ruggedized trays designed specifically for installations on Helicopter aircraft are also available.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal B. Cabling Notes Before proceeding with the installation of the HSD transceiver, read all cabling notes provided on the HSD System Interconnection Diagram for the applicable HSD system operational mode. (1) HSD Transceiver Cabling When installing the HSD transceiver, follow the cabling requirements listed below: • Maximum recommended cable length should not exceed 50 feet.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 7. Mechanical Installation This section describes the mechanical installation requirements for the HSD and HSD-X units. The outline and installation drawings for both transceivers are provided at the end of this section. A. General This section contains the information required to plan the physical placement of the HSD and HSD-X (Multi-Channel configurations only) transceivers.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–1. HSD-X Physical Placement Requirements C. Environmental Requirements The environmental requirements that must be considered during the physical placement of the HSD and HSD-X transceivers are based on the RTCA/DO-160D Environmental Specifications detailed in "System Description" on page 1-1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (c) HSD Fan Tray Requirements WARNING: Failure to install and configure the fan tray assembly as instructed may seriously compromise the HSD’s extreme temperature operation. Fan tray assemblies may be shipped with or without hole-plug-buttons installed. For adequate airflow to the HSD subassemblies, the plugs must be installed or removed in the fan/tray configuration as illustrated in Figure 3–2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 8. Electrical Installation This section provides mode-specific installation details for HSD and HSD-X transceivers. This section is divided into sub-sections that provide the electrical installation requirements for the different modes of operation.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Access to the HSD Maintenance Utility Program is achieved by connecting an RS-232, VT-100 terminal (PC or Laptop operating a terminal emulation program) to the RS-232 Maintenance Port. The HSD Maintenance port is available at the front of the HSD and at the rear ARINC 600 connector. Connection on the front of the HSD is accessible via a DB25S connector for local maintenance of the unit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • AFG: Airframe DC Ground • FAC: Fwd Address Common (TP7K) Resolve any conflict between WOW1 and WOW2 by assuming the aircraft is “in-air.” The interpretation of the state of the WOW1 and WOW2 pins is defined by the state of the WOW program select pin. Refer to Table 3–4 for details. 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–3. Forward ID, Hex to Binary Conversion Note: A pin strapped to the same potential as T7K (Forward address common) is considered as a logical “0”, whereas an open circuit pin is considered as a logical “1”. MSB is the Most Significant Bit and LSB is the Least Significant Bit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal A “remote reset switch” for HSD transceivers can also be installed and located with the Remote Status Panel. Figure 3–4 illustrates a typical wiring diagram for the remote reset circuit. Note: Cooperative and Combined Mode installations and HSD-X transceivers DO NOT support the use of the reset function. 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–5. HSD Remote LED Panel Circuit – Stand-Alone (g) User Interfaces – Stand-Alone To facilitate user access to the HSD interfaces, install the following connectors in the appropriate cabin area.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Install an RJ-45 interface connector in the cabin area for user access to the Ethernet interface. The next section describes the RJ-45 connector and cable termination. 4. RJ-45 Connector Termination Details Details relating to the RJ-45 cable terminations, required for both the ISDN and/or 10BASE-T services, are shown in Table 3–5 and Figure 3–6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. System Configuration Pin Strapping – Stand-Alone The HSD adjusts its configuration according to the status of several strap pins on the rear ARINC 600 connector. Configuration pins are assigned based on system mode configuration selection and data input/output (I/O) requirements, as shown in Table 3–6. Detailed pin assignment is shown in Table 3–7 and Table 3–8. Table 3–6.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • A “restricted” channel is not handled by the Data I/O Controller, which results in the channel not being accessible for SCPC via Ethernet or for MPDS via RS232 or Ethernet. • An SCPC channel is accessible for SCPC via Ethernet. • An MPDS channel is accessible for MPDS via RS232 and Ethernet. • An “unrestricted” channel is accessible for SCPC via Ethernet and MPDS via RS232 and Ethernet.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–7. User Data I/O Mode Configurations – Stand-Alone (h) ARINC 429 IRS Bus Interface – Stand-Alone In Stand-Alone Mode installations, navigational information (refer to "System Description" on page 1-1 for more information) is provided to the HSD through the high-speed ARINC 429 IRS bus interface.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–9.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–10.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–10.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1. BSU Pin nomenclature for Mechanically-Steered Antennae (MA) is manufacturer dependent. 2. “Other antenna types” (OA) represent either conformal or phased array antennae. Table 3–11.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–11.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–11.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Note: All connections, except power and RF, are HSD specific. Refer to “other SATCOM” and antenna manufacturers’ installation documentation for interconnection wiring details. (a) Maintenance Port Interface – Combined/Selective The HSD transceiver has an RS-232 Maintenance Port interface that provides access to a maintenance utility program for data loading, system monitoring, and testing purposes.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Selective Mode Installations Labeled as WOW1, WOW2, and WOW Program Select, these discretes are wired only if equivalent information is not strapped as being available to the SDU on an ARINC 429 input [for example, IRS or the Centralized Fault Display System (CFDS)].
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–8. Forward ID, Hex to Binary Conversion – Combined/Selective Note: A pin strapped to the same potential as T7K (Forward address common) is considered as a logical “0”, whereas an open circuit pin is considered as a logical “1”. Note: MSB is the Most Significant Bit and LSB is the Least Significant Bit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (e) Remote Status Panel – Combined/Selective (Optional) An optional “remote status panel” may be installed in installations where the HSD units are located in inaccessible or remote locations. The installation of a “remote status panel” is recommended as it provides visual indications of each of the power, fault, and call status of each of the units.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–10. HSD Remote LED Panel Circuit – Combined/Selective (f) User Interfaces – Combined/Selective To facilitate user access to the HSD interfaces, install the following connectors in the appropriate cabin area.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Install an RJ-45 interface connector in the cabin area for user access to the Ethernet interface. The next paragraph, describes the RJ-45 connector and cable termination. 4. RJ-45 Connector Termination Details Details relating to the RJ45 cable terminations, required for both the ISDN and/or 10BASE-T services, are shown in Table 3–15 and Figure 3–11.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. System Configuration Pin Strapping – Combined/Selective The HSD adjusts its configuration according to the status of several strap pins on the rear ARINC 600 connector. Configuration pins are assigned based on system-mode-configuration selection and data input/output (I/O) requirements as shown in Table 3–16. Detailed pin assignment is shown in Table 3–17 and Table 3–18. Table 3–16.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–17. Combined Mode System Mode Pin Strapping Pin Status System Modes TP4A TP4B TP4C TP4D 1 2 3 4 Collins Cooperative 0 0 1 1 Multi-Channel 0 0 0 1 Note: The logic for the System Mode pins is reverse to the logic explained in ARINC 741 Characteristic Attachment 1-4, Note 19. For System Mode pins, 0=strapped to common and 1=open.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–18.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–12. User Data I/O Mode Configurations – Combined/Selective (g) ARINC 429 IRS Bus Interface – Combined/Selective In HCM Combined Mode and Selective Mode installations, navigational information (refer to "System Description" on page 1-1 for details) is provided to the HSD through the high-speed ARINC 429 IRS bus interface.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal To install the RF Splitter: 1. Determine a suitable location near the RFU to secure the splitter. 2. Cut the receive coax cable at the splitter mounting location. 3. Re-terminate the cut ends with TNC coax connectors 4. Connect the end coming from the antenna subsystem to the splitter input (S) connector. 5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. “Other antenna types” (OA) represent either conformal or phased array antennae. Table 3–21.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–21.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal C. Section III: Cooperative Mode Installation (1) Cooperative Mode Installations Wiring Notes This section provides detailed information on the external interface and system connections involved in the installation of an HSD transceiver in Cooperative Mode operation.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • ISDN, Ethernet (if supported with an installed Data I/O Type 2 Card), and/or MPDS (RS-232) interface wiring • System and Data I/O Configuration lines • Optional maintenance and LED remote interfaces (b) Rockwell Collins Requirements for Cooperative Operation with SAT-906 At the time of printing, the SAT-906 SDU needs, at a minimum, core software – 068, that includes service bulletins 31 and 501, whic
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–23. RF Parameters Definition – Cooperative Mode Parameter HSD—Antenna (Tx) Loss Min. Value (dB) Max. Value (dB) 1 2.5 DLNA Insertion Loss (Tx to Antenna Port) – 0.8 (e) WOW Pin Wiring – Cooperative Mode In Cooperative Mode installations, WOW 2 discrete is re-assigned as Tx- Disable and is therefore not used.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–13. Forward ID, Hex to Binary Conversion – Cooperative Mode Note: A pin strapped to the same potential as T7K (Forward address common) is considered as a logical “0”, whereas an open circuit pin is considered as a logical “1”. Note: MSB is the Most Significant Bit and LSB is the Least Significant Bit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (g) Remote Status Panel – Cooperative Mode (Optional) An optional “remote status panel” may be installed in installations where the HSD is located in inaccessible or remote locations. The installation of a “remote status panel” is recommended as it provides visual indications of each of the power, fault, and call status of the HSD.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1. ISDN Interface Install an RJ-45 interface connector in the cabin area for user connections to the ISDN interface. "RJ-45 Connector Termination Details" on page 3-49 describes the RJ-45 connector and cable termination. 2. RS-232 Interface (MPDS) Install a DB9S interface connector in the cabin area for connection to the RS-232 interface. Refer to the HSD Interconnection Drawing for pinout designation. 3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–15. RJ-45 Connector Terminator Details – Cooperative Mode 5. System Configuration Pin Strapping – Cooperative Mode The HSD adjusts its configuration according to the status of several strap pins on the rear ARINC 600 connector. Configuration pins are assigned based on system-mode-configuration selection, and data input/output (I/O) requirements as shown in Table 3–25.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–26.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • A “restricted” channel is not handled by the Data I/O Controller, which results in the channel not being accessible for SCPC via Ethernet or for MPDS via RS232 or Ethernet. • An SCPC channel is accessible for SCPC via Ethernet. • An MPDS channel is accessible for MPDS via RS232 and Ethernet. • An “unrestricted” channel is accessible for SCPC via Ethernet and MPDS via RS232 and Ethernet.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–16. User Data I/O Mode Configurations – Cooperative Mode (i) ARINC 429 IRS Bus Interface – Cooperative Mode Although the IRS bus connections are not required, the installation of provisional wiring for these connections is recommended. (j) Antenna Interface – Cooperative Mode The SAT-906 Aero H/H+ system provides the interface to the antenna.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Connect the end coming from the antenna subsystem to the splitter input (S) connector. 5. Connect the end going to TPC1 of the RFU to one of the output ports of the splitter, one or two. 6. Run a new coax cable (length is installation specific) from the unused splitter output port to BP-12 of the ARINC 600 connector of the HSD tray assembly. Table 3–28.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–29.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–29.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–29.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–30.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–30.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (a) Multi-Channel Coaxial Cable Loss Considerations – Multi-Channel When installing a Multi-Channel HSD configuration, the transmit loss between the HSD-X slaves and the HSD-128 master must be considered. This loss, taking into consideration the cables, the combiner, and the attenuator, should come as close as possible to 29.5 dB (as shown in Table 3–32). For an illustrated example, refer to Figure 3–17.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (b) HSD-128 Transceiver Multi-Channel Configuration Installations The tables in this section provide all top, middle, and bottom plug, connection details for Stand-Alone Mode installations for the HSD-128 transceiver—specific to Multi-Channel HSD configurations.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (e) Antenna Subsystem RF Interface – Multi-Channel Several external RF parameters (such as cable losses and antenna gain), that must be delimited to ensure proper operation, dictate the HSD performance requirements. Table 3–33 defines these parameters and their expected values. Table 3–33. RF Parameters Definition – Multi-Channel Parameter (f) Min. Value (dB) Max.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal WOW wiring is optional for system operation in Stand-Alone Mode installations as the HSD already receives speed information for Doppler correction. However, if WOW wiring is not wired, normal maintenance must be disabled when speed or Doppler readings are greater than zero. Table 3–34.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–18. Forward ID, Hex to Binary Conversion – Multi-Channel Note: A pin strapped to the same potential as T7K (Forward address common) is considered as a logical “0”, whereas an open circuit pin is considered as a logical “1”.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Note: MSB is the Most Significant Bit and LSB is the Least Significant Bit. (h) Remote Status Panel – Multi-Channel (Optional) An optional “remote status panel” may be installed in installations where the HSD and/or any HSD-X units are located in inaccessible or remote locations.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–19. HSD Remote Reset Circuit – Multi-Channel Figure 3–20. HSD Remote LED Panel Circuit – Multi-Channel Figure 3–21.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (i) User Interfaces – Multi-Channel To facilitate user access to the HSD interfaces, install the following connectors in the appropriate cabin area.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–35. RJ-45 Wiring Details – Multi-Channel SERVICE EURO ISDN Signal Pin Ethernet Cable ECS Pin Other 10BASE-T Cable ECS Other RX + 3 White White/Green 3 White White/Orange stripe RX− 6 Blue Green 6 Green Orange/White stripe or solid Orange TX+ 4 White Blue 1 White White/Green stripe TX− 5 Orange White/Blue 2 Brown Green/White stripe or solid Green Figure 3–22.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–36.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Pins marked “1” are signaled by an open circuit—no connection. • Configuration resulting in all “1’s” is Invalid. 7. User Data I/O Mode Pin Strapping – Multi-Channel Data I/O Mode Pin strapping is only required for HSD transceivers models, PN 1110-A-0150 and 1110-A-0160 or other HSD models that have Data I/O Type 2 cards installed via Service Bulletin 1110-SB-0004.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–38.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–23. User Data I/O Mode Configurations – Multi-Channel (j) Multi-Channel Configuration Connection Details The tables in this section provide all top, middle, and bottom plug connection details for Multi-Channel Configuration installations of HSD-128 transceivers and HSD-X transceiver extensions.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–39. HSD-128 Multi-Channel Configuration ARINC 600 Top Plug Connections I/O From Top Plug Signal Name To Description I 1A Multi-control A TP3E Multi-control from control card I 1B Multi-control B TP3F Multi-control from control card I 2A BSU Top/Port BITE A (See Note 1) Mech.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–39. HSD-128 Multi-Channel Configuration ARINC 600 Top Plug Connections I/O From Top Plug Signal Name To Description O 3F OUT Multi-Control B IN Multi Ctrl B (TP1B), and Multi-Control-LO to HSD MA: BSU, Pin B or U, or & Antenna Subsystem OA: BSU, PORT-U & STBD-U I 2K Remote Reset I 3G I 3H WOW 1 Normally open Remote System Reset momentary switch—open side.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–39.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–40. HSD-128 Multi-Channel Configuration, ARINC 600 Middle Plug Connections I/O From Middle Plug Signal Name To Description O 1F LED Common Remote Status LED LED Common Panel, and closed side of N.O.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–40.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (k) HSD-X Installations – Multi-Channel The tables in this section provide all top, middle, and bottom plug, connection details for of HSD-Xs integrated with the HSD-128 transceiver in Multi-Channel configurations. Table 3–42.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–42. HSD-X Top Plug Connections I/O From Top Plug Signal Name I 12D Fwd ID #12 I 13A Fwd ID #13 I 13B Fwd ID #14 I 13C Fwd ID #15 I 13D Fwd ID #16 I 14A Fwd ID #17 I 14B Fwd ID #18 I 14C Fwd ID #19 I 14D Fwd ID #20 I 15A Fwd ID #21 I 15B Fwd ID #22 I 15C Fwd ID #23 I 15D Fwd ID #24 (LSB) To Description Figure 3–24.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–43.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–43. HSD-X Middle Plug Connections– Multi-Channel From Middle Plug I/O I I O O Signal Name To Description 15A 10BASE-T RX+ Ethernet 10BASE-T, RJ45-3 15B 10BASE-T RX- Ethernet 10BASE-T, RJ45-6 15C 10BASE-T TX+ Ethernet 10BASE-T, RJ45-1 15D 10BASE-T TX- Ethernet 10BASE-T, RJ45-2 User Data, Ethernet 10BASE-T Table 3–44.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 3–46. Inter-LRU RF Connection Considerations for Attenuators– Multi-Channel Function From To Frequency (MHz) Loss VSWR HSD-X1 Tx HSD-X1 BP1 HSD-128 TPC1 1626.5-1660.5 29.5dB ± 1.5:1, max 3.0dB HSD-X2 Tx HSD-X2 BP1 HSD-128 TPC1 1626.5-1660.5 29.5dB ± 1.5:1, max 3.0dB HSD-X1 Rx DLNA HSD-X1 BP5 1525.0-1559.0 5.0dB to 1.5:1, max 24.0dB HSD-X2 Rx DLNA HSD-X2 BP5 1525.0-1559.0 5.0dB to 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 9. Outline/Installation and Interconnection/Contact Assignment Diagrams This section contains the outline and installation drawings and interconnection and contact assignment diagrams for all installation modes and configurations of HSD and HSD-X transceivers. All foldout pages are odd-numbered and “not-backed” for print production purposes. A.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page 3–84 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–25 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–26 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–27 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–28 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–29 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–30 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–31 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–32 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–33 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–34 (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–35 (Sheet 1).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–36. (Sheet 2).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–37 (Sheet 3).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 3–38 (Sheet 4).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal TEST AND FAULT ISOLATION 1. Introduction This section provides the information required to determine the operational readiness of the HSD and HSD-X transceivers and to aid service personnel in diagnosing system faults. The operational and diagnostic tests described in this section require using the HSD and HSD-X transceivers built-in diagnostic tool referred to as the HSD maintenance utility program.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 2. Operational and Diagnostic Testing A. General Usually, units require testing for one of the reasons listed below: • To verify the operational readiness of the unit during and after installation on an aircraft. • To verify that a fault exists and produce system reports for troubleshooting purposes. • To verify the operational readiness of repaired LRUs during re-installation on an aircraft.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–2. List of Optional Test Equipment Item Equipment Specification Quantity Service Provider Information Package Special Inmarsat service provider 1 Internet access Standard Inmarsat Swift64 high-speed-data 1 High speed data terminal Special Setup Guide MN-1110-10048 1 Time Domain Refectometer – 1 Standard C.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 4–1. Multi-Channel Maintenance Port Access (2) Connection Requirements This section describes specific cabling requirement needed to connect to and use the HSD Maintenance Port Utility program. (a) Cabling Notes The HSD and HSD-X transceivers provide two options for physical connection to the HSD maintenance port and utility program: direct connection and remote connection.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–4. Front-Panel Maintenance Port Access Cabling (HSD) Pin Definition Front Panel DB25S HSD Maintenance Cable Connector DB25P Maint Port SGND 10 10 Maint Port Rx 12 12 1 Cable (See Figure 4–3) Front Panel Access Computer DB9P 5 3 2 1 Table 4–5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 4–2. Remote Access, Maintenance Cable (HSD) Figure 4–3.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 4–4. HSD-X Front-Panel, Maintenance Port Cable (c) Interface Requirements A standard VT100 compatible terminal running an emulator program (such as HyperTerminal, ProComm Plus, or another similar serial communication package) provides the user interface to the HSD maintenance utility program. The RS-232 connection settings for HSD and HSD-X maintenance ports are the same.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (a) End User Access: Level 1 – Password: MENU This limited-access level is for anyone without technical training on the product. It provides read-only access to help users diagnose problems with the assistance of product support personnel. (b) Field Representative Access: Level 2 – Password: MAINT This level is for trained original equipment manufacturer (O.E.M.) installers and product support personnel.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (5) Menu Descriptions This section describes the menus and menu items available in the HSD maintenance utility program in Level 1 access (using the MENU password) and Level 2 access (using the MAINT password) based on control processor software version 4.5 and 7.0. The differences between version 4.5 and 7.0 are noted within the examples. All menus and items that appear in Level 1 also appear in Level 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (b) Level 2 Menu Selections (Password: MAINT) Figure 4–6 through Figure 4–12 show all menus and menu items available in Level 2, menu options in control processor software, version 7.0. Menu items added in version 7.0, control processor software are highlighted in bold. Where applicable, any items that were deleted in version 7.0 are described and noted below each menu.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU 4 Q O J channel card forward ID's set Ocean Region toggle ISDN connection N next menu Level 2: Menu 4 MENU10 L H P S X B N FIRMWARE V7.0 O next menu force spot beam selection change spot beam report MUX stats previous menu = select reports FIRMWARE V7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal V MENU 15 FIRMWARE V7.0 request channel card versions D N next menu O channel card serial number previous menu = select reports Figure 4–12. Level 2, Menu 15 MENU 18 X L FIRMWARE V7.0 HSD-X slave console mode list HSD-X slave cable loss N next menu O B V HSD-X slave cable loss get HSD-X firmware version previous menu = select reports Figure 4–13.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU1 X Y R FIRMWARE V7.0 override forward id explain hpa error status hcm RF threshold N next menu L S O test LEDs set hcm attenuator previous menu = select reports Figure 4–14. Menu 1 Screen Display Table 4–7. Menu 1 Item Descriptions Menu Item Description • Used in testing and fault isolation • Enter a “test or alternate” Forward ID to use during fault isolation procedures.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU2 FIRMWARE Vx.x A set veh-relative azimuth K desired az veh-rel velocity T enter time of day L re-enter logon password Z reset HSD-128 N next menu O E set veh-relative elevation R resume automatic steering N annotate log file V get firmware versions S set sat long previous menu = select reports Figure 4–15. Menu 2 Screen Display Table 4–8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • Added parameter 45, ‘Category B Lower Frequency Limit’ and Parameter 46, “Category B Upper Frequency Limit” — these two parameters specify the “CAT B” terminal frequency range. Calls, which involve transmitting outside of this range, may interfere with the GPS navigational system if an Aero H call occurs at the same time. Usually the GPS protection algorithm tears down these calls.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–9.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal EEPROM LISTING: MAGIC NUMBER :OK EEPROM VERSION NUMBER 2001 FIRMWARE VERSION 1018 SERIAL NUMBER: xxx IGNORED FAULTS: 0 HARDWARE CONFIG: 0 NUMBER OF POWERUPS (index 0) 570 HOURS OF OPERATION (index 0) 117 MISCELLANEOUS PARAMETERS HIT 'L' for MORE HPA-ANTENNA CABLE LOSS: 2.5 dB FORWARD ID: xxxxxx AORW LES ACCESS CODE: 1 TERRESTRIAL NETWORK ID: 0 HPA-CHANNEL CARD CABLE LOSS: 10.0 dB MAX HPA GAIN: 66.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Note: Depending on the version of software installed and the Terminal Category, the EEPROM Listing shown may differ from those shown and described here.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–10. Menu 3, Item 'M' EEPROM Parameter Descriptions (Version 4.5) Parameter # 1 Parameter Title HPA Cable loss Description • Measured transmit coax cable loss from the HSD at MPC1 to the antenna including the DLNA loss (0.8 dB) • Maximum is 2.5 dB – 0.8 dB = 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–10. Menu 3, Item 'M' EEPROM Parameter Descriptions (Version 4.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–11. Menu 3, Item 'M' EEPROM Parameter Descriptions (Version 7.0) Parameter # Parameter Title Description 1 HPA cable loss • Measured transmit coax cable loss from the HSD at MPC1 to the antenna including the DLNA loss—maximum is 2.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–11. Menu 3, Item 'M' EEPROM Parameter Descriptions (Version 7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–11. Menu 3, Item 'M' EEPROM Parameter Descriptions (Version 7.0) Parameter # 24 Parameter Title Description Receiver Calibration • (AERO) Enables attenuation of receive RF input level to the channel cards • Entered as an absolute number, e.g.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (d) Menu 4 In control-processor software version 7.0, the following changes were made to Menu 4 selections (delta between version 4.5 and 7.0). No additional menu items were added with the release of Version 7.5, Control Processor software. • Removed Menu 4, item F, ‘force spot beam’ selection. Figure 4–20 shows the HSD maintenance utility program Menu 4 screen display.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (e) Menu 10 Menu 10 items are used to manually enter INS parameters to simulate the INS data required for HSD operation when INS data is unavailable. Figure 4–21 shows the HSD maintenance utility program Menu 10 screen display. Table 4– 13 describes the items available in Menu 10. No additional menu items were added with the release of Version 7.5, Control Processor software.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–13.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–14.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (h) Menu 15 Menu 15 was added in control processor software version 7.0 to allow the user to query the system for channel-card, software versions and serial number information. Figure 4–24 shows the HSD maintenance utility program Menu 15 screen display. Table 4–16 describes the items available in Menu 15. MENU 15 V FIRMWARE V7.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–17.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1 OFF messages to channel card #1 2 OFF hex output to channel card #1 3 OFF responses from channel card #1 4 OFF hex input from channel card #1 5 OFF channel #1 misc info 6 OFF sb antenna arinc input 7 OFF sb antenna maintenance word 8 OFF sb antenna status word 9 OFF channel card call status 10 OFF channel card THA codes 11 OFF channel card errors 12 OFF INS input 13 OFF messages to channel card #2 14 OFF
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 1 OFF messages to channel card #1 2 OFF hex output to channel card #1 3 OFF responses from channel card #1 4 OFF hex input from channel card #1 5 OFF channel #1 misc info 6 OFF sb antenna arinc input 7 OFF sb antenna maintenance word 8 OFF sb antenna status word 9 OFF channel card call status 10 OFF channel card THA codes 11 OFF channel card errors 12 OFF INS input 13 OFF messages to channel card #2 14 OFF
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (8) Activating Maintenance Reports In Level 1, menu access, report item 23 (standard output) is automatically generated when the equals sign (=) is pressed. Once activated, the report data output is repeated on the computer display at one-second intervals. Level 2, maint access provides more flexibility in the use of the reports function.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–18.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Report 5; Channel card #1 & #2 miscellaneous information: CARD #1: C/No=51.8 sig=-16.6 no call beam=4 AOR WEST bt=OK oc=OK int=8080 CARD #1: C/No=51.6 sig=-16.8 no call beam=4 AOR WEST bt=OK oc=OK int=8080 CARD #2: C/No=52.0 sig=-16.1 no call beam=4 AOR WEST bt=OK oc=OK int=8080 CARD #2: C/No=51.7 sig=-16.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–19.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–20.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal The procedures assume that the technical personnel are familiar with the test equipment used and can operate the equipment to produce the required inputs and obtain the required results (indications). Refer to the detailed operating procedures and descriptions of the HSD Maintenance Utility Program included in this section.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (3) Post Test When testing is completed: 1. Save the log file of the test results (or data) for future reference. 2. Remove power from the unit under test and all other test equipment. 3. Disconnect test equipment from the HSD or HSD-X unit. 4. Replace the maintenance-port connector cover (if previously removed during the test setup).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–23. HSD Electrical Verification STEP 1.0 Item Checked Verification Description Power Model 1110-A-0001/1110-A-0080/1110-A-0160: connections 28 V dc polarity Model 1110-A-0060/1110-A-0070/1110-A-0150: 115 V ac polarity Chassis Ground @ BP8 – resistance measurement 2.0 Voltage levels CAUTION: When power is applied to the rack, the fan energizes.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–24. HSD Electrical Verification STEP Item Checked Verification Description 5.0 Remotes Remote Reset switch operation (Optional—but Maintenance Port, remote access recommended) Power and Fault LED indicators 6.0 RF Coax Rx input cable loss from DLNA to HSD at BP12 and to the RFU at TPC1 (including splitter) Tx output cable loss from HSD at MPC1 to DLNA 7.0 8.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal EEPROM LISTING: MAGIC NUMBER :OK MAGIC NUMBER :OK EEPROM VERSION NUMBER 2001 FIRMWARE VERSION 1018 SERIAL NUMBER: xxx IGNORED FAULTS: 0 HARDWARE CONFIG: 0 NUMBER OF POWERUPS (index 0) 5 HOURS OF OPERATION (index 0) 11 MISCELLANEOUS PARAMETERS HIT 'L' for MORE HPA-ANTENNA CABLE LOSS: 2.5 dB FORWARD ID: xxxxxx AORW LES ACCESS CODE: 1 TERRESTRIAL NETWORK ID: 0 HPA-CHANNEL CARD CABLE LOSS: 10.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal HSD SERIAL NUMBER S/N ??? MISCELLANEOUS PARAMETERS HPA TO ANTENNA LOSS: 3.5 dB MANUALLY SET FORWARD ID: 000000 MANUALLY SET GPS PROTECTION ALGORITHMS: DISABLED MANUALLY SET REGISTRATION REQ'D BEFORE CALLS: DISABLED MANUALLY SET CHANNEL CARD TO HPA LOSS: 10.0 dB MANUALLY SET MAX HPA GAIN: 65.00 dB MANUALLY SET MIN ANTENNA GAIN: 8.0 dB MANUALLY SET MAX EIRP: 52.5 dBm MANUALLY SET MAX CHANNEL_CARD POWER: 0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal ORT ORT ORT ORT TOOL TOOL TOOL PART NAME: PART NUMBER: OEM VERSION: NUMBER: CHECKSUM (stored at offset 464) 12133 longest write cycle took 0 MSEC OK Figure 4–31. HSD ORT Sample Display (software version 5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal KERNEL Vx.x -- Mon Oct 07 13:36:26 2002 TESTING RAM ......RAM OK. HSD APPLICATION Vx.x -- Thu Apr 24 08:02:39 2003 Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Once the power up messages appear: 2. • Enter the Level 2, password: maint 3. Press the equal sign on the keyboard (=) to access the “reports” menu, then activate report items 21 (call codes) and 23 (standard output). Remember to save these selected items by using the “S” (save to EEPROM) command. 4. In Menu 2, press Z to reset the HSD.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal KERNEL V1.6 -- Mon Oct 07 13:36:26 2002 TESTING RAM ......RAM OK. HSD APPLICATION Vx.x -- Thu Oct 10 08:36:29 2002 Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (c) On-Air Voice/Data Call Verification Once the system has logged on, place a test voice and/or data call. Refer to "System Description" on page 1-1 for detailed call procedures. Verification of all aircraft communication functions is recommended. Record the test call result on the Installation Checklist provided in "Installation Checklist" on page D-1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 12:43:24 #1 ABC123 E4 start 800124 14.00 dBW mobile aero 64k speech 28 C 47 dB/Hz 12:43:24 dop 0 ppb az 285.4 deg el 15.3 deg AOR EAST ant gain 12 (p/t) CARD #1: C/No=*** sig=-16.4 dB 28 C IDLE IN CALL beam=4 CARD #2: C/No=47.3 dB/Hz sig=-15.2 dB 30 C no call beam=4 45D21'16.1"N 75D0'0.2"W PT -10.0D RL 0.0D HD 185.0D TK 0.2D 0 knots 12:43:25 dop 0 ppb az 285.4 deg el 15.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal • As directed in previous tests, connect a computer to the maintenance port and use Level 2, maint password to access the HSD maintenance utility program. • Power up all avionics and align the IRS. • Taxi or tow the aircraft to an unobstructed, line-of-site location where a complete 360° rotation is possible.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal F. Operational Mode and Configuration System Checks This section describes system checks designed for specific HSD modes of operation. (1) Verifying Cooperative Mode System Operation This section provides system operational verification procedures that are specific to Cooperative Mode installations.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (b) Checking EIRP power Check EIRP power values during system operation using the HSD Maintenance Port Utility program. Place a number of call types and combinations while using the “reports” function of the HSD Maintenance Port Utility program and record the reported values in "Installation Checklist" on page D-1. (c) Test Set-up Procedure 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 6. Place two HSD Swift64 ISDN voice calls (one call from each channel card) and while both calls are connected, place two Aero H/H+ voice calls. The Aero Watts value should initially increase to a value of 8 to 10 W and then stabilize to lower watt value of 1.5 to 2.5 W when the call has stabilized. Refer to Figure 4–43 and Figure 4–44. 7. Toggle OFF report 78. (Press = , then type 78.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal CHANNEL CARD EIRP/WATTS #1 0.0/0 #2 0.0/0 HPA (ITS): 9.0 WATTS A CHANNEL CARDS: 0.0 WATTS ANT GAIN: 12 15:10:02 PERMITTED UNDERDRAFT: 0.0 dB ADD M4 CALL: 20 WATTS AERO WATTS: USED=10 RESERVED=23 HPA=36 WATTS HPA GAIN=62.2 dB Figure 4–38. Call Initialization (Aero H/H+ call) CHANNEL CARD EIRP/WATTS #1 0.0/0 #2 0.0/0 HPA (ITS): 2.2 WATTS H CHANNEL CARDS: 0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal CHANNEL CARD #1 EIRP/WATTS 18.5/8 #2 17.5/6 HPA (ITS): 22.5 WATTS A CHANNEL CARDS: 14.2 WATTS ANT GAIN: 12 12:10:22 PERMITTED UNDERDRAFT: 5.0 dB ADD M4 CALL: 06 WATTS AERO WATTS: USED=11 RESERVED=24 HPA=36 WATTS HPA GAIN=62.8 dB Figure 4–43. Initial Connection with two Aero H/H+ calls and two M4 (Swift64) calls CHANNEL CARD #1 EIRP/WATTS 18.5/8 #2 17.5/6 HPA (ITS): 17.9 WATTS A CHANNEL CARDS: 14.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (3) Verifying Multi-Channel Configuration System Operation This section provides system operational verification procedures that are specific to Multi-Channel configuration installations. The following system verification procedures use the HSD Maintenance Port Utility Program to access system information. Note: Record all test results in "Installation Checklist" on page D-1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU 18 X HSD-X slave console mode L list HSD-X slave cable loss N next menu O FIRMWARE Vx.x B HSD-X slave cable loss V get HSD-X firmware version previous menu = select reports TERMINAL: HSD-X NETWORK MODE which slave (1 thru 2 -- 0=none) ? 1 Slave #1 console mode. Press ~ to exit.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal CHANNEL CARD EIRP/WATTS #1 0.0/0 #2 0.0/0 S1 0.0/0 S2 0.0/0 HPA (ITS): 4.0 WATTS H CHANNEL CARDS: 0.0 WATTS ANT GAIN: 14 11:33:28 PERMITTED UNDERDRAFT: 0.0 dB ADD M4 CALL: 14 WATTS AERO WATTS: USED=00 HPA=60 WATTS HPA GAIN=59.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal CHANNEL CARD #1 EIRP/WATTS 18.5/10 #2 0.0/0 S1 0.0/0 S2 0.0/0 HPA (ITS): 14.2 WATTS A CHANNEL CARDS: 10.1 WATTS ANT GAIN: 12 11:39:36 PERMITTED UNDERDRAFT: 0.0 dB ADD M4 CALL: 25 WATTS AERO WATTS: USED=00 HPA=60 WATTS HPA GAIN=62.6 dB Figure 4–46. Stable Call, Channel #1 CHANNEL CARD #1 #2 S1 S2 EIRP/WATTS 17.5/8 18.5/10 19.5/10 20.5/16 HPA (ITS): 50.4 WATTS A CHANNEL CARDS: 43.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal When loading software to HSD units in installation environments that include an SDU, disable the SDU (Power off or remove the sdu from the arinc tray) before beginning the software load procedure. Note: Refer to the applicable software release note or service bulletin for a specific list of the software files that need to be loaded.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal HSD/HST LOADER Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal HSD/HST LOADER Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal To load control processor software: 1. Connect a computer to the Maintenance Port of the HSD transceiver. 2. Turn on the computer. 3. Save the HSD Load Program file (PN 1110-SW-1021) to a folder on your PC. (Recommended: Create a folder named HSD Load in the PC’s root directory and save the load application file to this folder.) 4. Apply power to the HSD or HSD-X transceiver. 5.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 10. Type the appropriate COM port (1 or 2—typically 1), and then press Enter. 11. To proceed with the load, press Enter. Note: If you press Esc, the application aborts the software load. Only press Esc if you want to discontinue the software load procedure. Communication with the HSD or HSD-X transceiver is established. The following screen appears.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (3) Forcing Channel Card Power Up Procedure In installation environments that include an SDU, the SDU must be disabled before loading software to the HSD transceiver. With the SDU disabled (removed from the ARINC tray or powered off), the channel card(s) must be manually powered on using the HSD Maintenance Utility Program.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. Close all other applications running on the computer (especially programs that use the serial COM port, e.g. HyperTerminal). The load program may not execute successfully if other programs are running. In the HSD folder, double-click on the ADT_LOAD.exe to launch the load program. The ADT_LOAD application opens in a DOS window and displays the “Load Target” menu. HSD/HST LOADER Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal successfully loaded, and then the DOS window closes. This completes HPA software load. If all software loads are finished, verify the success of the software load by following the instructions provided in "Verifying Software Loads" on page 4-78. 14. In the event that the load fails, restart the load from the beginning of "Loading HPA Software" on page 4-76.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU2 FIRMWARE Vx.x A set veh-relative azimuth K desired az veh-rel velocity T enter time of day L re-enter logon password Z reset HSD-128 N next menu O E R N V set veh-relative elevation resume automatic steering annotate log file get firmware versions previous menu = select reports 6. To display the versions of software loaded onto the HSD, press V.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (7) Completing Record of Accomplishment After completing all required software loads and the load verification, fill out the Record of Accomplishment form provided in "Record of Accomplishment" on page E-1. (Retain a copy for future reference.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 3. Troubleshooting and Fault Isolation This section provides troubleshooting procedures for HSD units experiencing faults during the commissioning process or previously operational units now considered as “not working”. Troubleshooting procedures require data obtained using the Maintenance Utility Program feature of the HSD units.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal KERNEL Vx.x -- Mon Oct 07 13:36:26 2002 TESTING RAM ......RAM OK. HSD APPLICATION Vx.x -- Thu Apr 24 13:28:58 2003 Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 12:43:55 dop**** az 285.4 deg el 15.3 deg AOR EAST ant gain 11 (p/t) CARD #1: C/No=52.9 dB/Hz sig=-16.9 dB 27 C no call beam=4 CARD #2: C/No=52.9 dB/Hz sig=-18.2 dB 27 C no call beam=4 ************ *********** ********* ******** ********* ******* ******* CARD #1: C/No=52.4.0 dB/Hz sig=-17.6 dB 27 C in call beam=4 CARD #2: C/No=52.4 dB/Hz sig=-18.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 10:00:35 Tue Jun 3, 2003 KERNEL Vx.x -- Mon Oct 07 13:36:26 2002 TESTING RAM ......RAM OK. HSD APPLICATION Vx.x -- Thu Apr 24 13:28:58 2003 Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal KERNEL Vx.x -- Mon Oct 07 13:36:26 2002 TESTING RAM ......RAM OK. HSD APPLICATION V4.6 -- Thu Apr 24 13:28:58 2003 Type "menu" to activate the maintenance port menus. Other passwords provide different levels of authorization.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 10:51:26 #2 ABC456 E5 start 400110 14.00 dBW CT SP ocean region registration 30 C 54 dB/Hz 10:51:26 #1 ABC123 E5 start 400110 14.00 dBW CT SP ocean region registration 29 C 54 dB/Hz 10:51:27 #2 ABC456 E5 start 400110 14.00 dBW CT SP ocean region registration 30 C 10:51:27 #1 ABC123 E5 start 400110 14.00 dBW CT SP ocean region registration 29 C 10:51:27 #1 ABC123 E5 start 400110 14.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Log-on password entered: "Maint" MENU1 FIRMWARE Vx.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MENU1 FIRMWARE Vx.x X override forward id Y explain hpa error status N next menu O HPA UNCONTROLLED L test LEDs previous menu = select reports Y command entered: HPA MAINTENANCE WORD REPORTING ARINC ERROR HPA STATUS WORD REPORTING INVALID SSM 1 (NO COMPUTED DATA) Event log messages: MENU 3 L list EEPROM E reset EEPROM M misc.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Enter 1 thru 67 to toggle report on/off X turn off all reports N show next page ESC return to PREVIOUS MENU S save to EEPROM 1 OFF messages to channel card #1 13 OFF messages to channel card #2 2 OFF hex output to channel card #1 14 OFF hex output to channel card #2 3 OFF responses from channel card #1 15 OFF responses from channel card #2 4 OFF hex input from channel card #1 16 OFF hex input from
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 12:43:24 #1 ABC123 E4 start 800124 14.00 dBW mobile aero 64k speech 28 C 47 dB/Hz 12:43:24 dop 0 ppb az 285.4 deg el 15.3 deg AOR EAST ant gain 12 (p/t) CARD #1: C/No=*** sig=-16.4 dB 28 C IDLE IN CALL beam=4 CARD #2: C/No=47.3 dB/Hz sig=-15.2 dB 30 C no call beam=4 45D21'16.1"N 75D0'0.2"W PT -10.0D RL 0.0D HD 185.0D TK 0.2D 0 knots 12:43:25 dop 0 ppb az 285.4 deg el 15.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal .) 12:43:24 #1 ABC123 E4 start 800124 14.00 dBW mobile aero 64k speech 28 C 47 dB/Hz 12:43:24 dop 0 ppb az 285.4 deg el 15.3 deg AOR EAST ant gain 12 (p/t) CARD #1: C/No=*** sig=-16.4 dB 28 C IDLE IN CALL beam=4 CARD #2: C/No=47.3 dB/Hz sig=-15.2 dB 30 C no call beam=4 45D21'16.1"N 75D0'0.2"W PT -10.0D RL 0.0D HD 185.0D TK 0.2D 0 knots 12:43:25 dop 0 ppb az 285.4 deg el 15.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 13:40:53 Tue Jun 3, 2003 13:41:22 #1 ABC123 E4 start c00124 14.00 dBW fixed aero 64k speech 28 47 dB/Hz 13:41:25 #1 ABC123 E4 start c00124 22.50 dBW fixed aero 64k speech 28 48 dB/Hz 13:41:35 #1 ABC123 E4 start c00124 18.50 dBW fixed aero 64k speech 28 53 dB/Hz 13:41:41 #1 ABC123 E4 start c00124 19.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 13:33:27 Tue Jun 3, 2003 13:38:22 #2 ABC456 E4 start 800622 14.00 dBW mobile aero 64k UDI 30 C 47 dB/Hz 13:38:25 #2 ABC456 E4 start 800622 22.50 dBW mobile aero 64k UDI 30 C 47 dB/Hz 13:38:35 #1 ABC123 E4 start 800124 14.00 dBW mobile aero 64k speech 28 C 47 dB/Hz 13:38:36 #2 ABC456 E4 start 800622 22.50 dBW mobile aero 64k UDI 30 C 55 dB/Hz 13:38:37 #1 ABC123 E4 start 800124 22.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation Fault Call failure Call failure Call failure Call failure Description IRS information not available Maintenance Report Activate maintenance reports 21 and 23 (See Figure 4–51) System does not log onto the Activate broadbeam maintenance reports 21 and 23 (See Figure 4–53) Check • Check that the IRS systems are powered on and aligned.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation Fault Call failure Description Forward ID is invalid or strapped incorrectly Page 4–96 18 September 2007 Maintenance Report Check Activate • maintenance report 21 (See Figure 4–54) To check FWD ID, in Menu 4, press Q The account registration process has not been completed.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation Fault Description Log-on Unit is not receiving request fails Incoming call failure Maintenance Report Activate maintenance reports 21 and 23 (See Figure 4–52) Incoming call shows as a Activate report successful connection in 21and 23 report 23, but call does not ring through to the external device (telephone, computer, fax).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation Fault Description Log-on Authorization error (fault successful, code 12C4) but fails to complete call Maintenance Report Activate maintenance reports 21 and 23 (See Figure 4–53 and Figure 4–51) Check • Contact your service provider to verify that the forward ID is activated. • Check that the Forward ID is strapped correctly.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–27. Troubleshooting and Fault Isolation Fault No dial tone – heard in handset Call drops after successful connection Maintenance Report Description If the RF signal fades significantly (during a call) the connection may drop Note: A sudden, severe aircraft banking angle may obstruct the signal – Activate report 21 and 23 Check • Confirm ISDN lines are wired correctly.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Perform all fault isolation procedures provided in this section. Record and document all test results including: LEDs function and maintenance port data outputs (report items 21 and 23). Enable report items 18, 19, and 20 (Port) or items 6, 7, and 8 (Starboard) to record antenna, ACU, and DLNA related faults. Enable other report items as required.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 13. To save an alternate “reports” configuration, activate the required items and then press S (in the “reports” menu) to save to EEPROM. 14. Using Ctrl+N, go to menu 3, and then do one of the following: • For units operating control processor software earlier than version 5.7, press L to display EEPROM parameters. (The EEPROM list displays one terminal screen of information at a time.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Adjustment/Alignment Procedures A. General There are no adjustment/alignment procedures required for HSD or HSD-X transceivers.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5. Modification History Table 4–28 lists the modification history for the HSD transceiver. This history is provided to aid the technician in understanding the reason for issuing a service bulletin and to describe the changes to the equipment. Table 4–28. Modification History Service Bulletin 1110-SB-0001/A Description of Modification Upgrades channel card software to version 3.0.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Table 4–28.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal MAINTENANCE AND REPAIR 1. General This section provides the maintenance and repair information applicable for all HSD transceiver models. 2. Maintenance The HSD Transceiver does not require routine maintenance. 3. Repair All repair procedures must be completed by EMS SATCOM approved repair facilities. A. Repair Tools and Supplies No special supplies are required to repair this equipment.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Figure 5–1. HSD-X Order of Removal D. Repair Facility Approvals The EMS Technologies SATCOM Division, located at 400 Maple Grove Road in Ottawa, Ontario, Canada, is a Transport Canada Approved Maintenance Organization (AMO).
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal (4) Return Materials Authorization (RMA) Procedure If it is determined that a unit must be returned to EMS SATCOM for repair or overhaul, please follow the Return Materials Authorization procedure as follows: 1. Have the following information ready before calling the SATCOM Product’s Customer Service Center: • Model number (e.g. HSD); • Unit part number (e.g.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 4. Instructions for Continued Airworthiness, FAR 25.1529 This section presents the special instructions and maintenance requirements for continued airworthiness of the HSD High-Speed Data Transceiver.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX A: INMARSAT SATELLITE BEAM COVERAGE Inmarsat operates four, strategically placed geostationary satellites. Each satellite is located over and named after an oceanic region.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Page A–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Page A–3 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page A–4 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX B: TROUBLESHOOTING CHECKLIST Before proceeding to the detailed testing and troubleshooting procedures provided in this manual, read the following QuickStart Troubleshooting Checklist. The QuickStart Troubleshooting Checklist provides answers to common HSD system activation questions. 1.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal 5 Have any changes to the system been made? For previously installed and functional units, make note of any changes made to the system since the last time the unit functioned without problems. • Were any new devices or systems connected to the unit? • Have any connecting devices or equipment been removed or replaced? If so, check that all new or replaced connections are attached and configured correctly.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX C: RJ-45 CABLE TERMINATION DETAILS Page C–1 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Page C–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX D: INSTALLATION CHECKLIST Aircraft Identification: HSD Installation Mode: Checks completed by: Approved/witnessed by: Installation/ Mechanical Section Name: HSD Model Number: HSD Serial Number: Signature: Parameter Physical Item Date: N/A R Value Service/maintenance access Environmental considerations Fan Tray Plug configuration Chassis bonding Fan rotation ARINC 600 Connector Polari
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Section Parameter Power Connections Item + 28 V dc polarity 115 V ac polarity Chassis grounding Voltage Measurements + 28 V dc level 115 V ac level IRS Input IRS wiring IRS format Configuration Strap Pins SDI System configuration Data I/O Forward Address Installation/Electrical WOW (optional) Ethernet Strapped to RJ45 distribution points ISDN Strapped to RJ45 distribution points MPDS Strapp
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Section Parameter Item N/A R Value Tracking results checklist completed Antenna Tracking Results Heading (Deg) Antenna selected HSD Antenna Azimuth Ch 1 HSDX Ch 2 #1 #2 C/NO sig C/NO sig C/NO sig C/NO sig 15 30 45 60 75 90 Operational Test 105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 TEST 345 360 Optional Checks Ground segment Flight segment Page D–3 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Section Parameter Item N/A R Value Tracking results checklist completed Antenna Tracking Results Heading (Degrees) Antenna selected Antenna Card # 1 Azimuth C/No 15 30 45 60 75 90 Operational Test 105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 TEST 345 360 Optional Checks Page D–4 18 September 2007 Ground segment Flight segment Card # 2 Signal C/No Signal
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX E: RECORD OF ACCOMPLISHMENT To record the accomplishment of a software service bulletin, complete a copy of this form for each unit (serial number) that has been upgraded. Fax or e-mail all Record of Accomplishments (one for each unit) to EMS Technologies. If you require assistance, contact EMS SATCOM Product Support. EMS SATCOM Product Support: 1.888.300.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page E–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal APPENDIX F: RF SPLITTER Page F–1 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Blank Page Page F–2 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Notes 18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL eNfusion™ HSD-128 High-speed Data Terminal Notes 18 September 2007