User's Manual

Low Frequency Exciters
Installation Guide
Part Numbers: 5-RLE00125, 5-RLE00125-1,
5-RLE00125-2
Elpas
ElpasElpas
Elpas
Active RFID Solutions
Page 1 of 8
DTA03N01_V13
General Overview
Elpas Low Frequency (LF) Exciters from Visonic
Technologies are supervised*, short-range, wireless
emitters that add pin point detection functionality to
EIRIS
TM
based RFID installations.
Elpas Low Frequency (LF) Exciters can be installed
surface mounted on walls or on fixed or in dropped
(false) ceilings. Elpas LF Exciters are deployable in
either a basic stand-a-lone configuration designed to cover normal size single doorways or in
a master–slave configuration (1 master and 1 slave unit) for accurate, synchronized coverage
of large indoor, open complex-shaped areas.
Elpas LF Exciters emit harmless, adjustable low power, low frequency; sphere shaped
magnetic (125 KHz) fields up to 3m (10ft) in radius. The emitted fields are user tunable so
that they can precisely cover any indoor doorway or restricted entrance/exit area. As a result,
whenever an active Elpas RFID tag or badge (i.e. ETC, WTA, Baby Tag, Personnel Badge)
enters the magnet field; the corresponding LF Exciter automatically triggers the moving RFID
device to transmit special data messages (including the Exciter ID code). The messages are
immediately received and relayed by strategically located Elpas RF readers for monitoring,
alert notification and subsequent event logging.
* LF Exciters (from hardware Version C) transmit operational RF status messages plus output
power trouble alert messages configurable and supervised via EIRIS software.
CAUTION: It is important that you read, understand, and follow the
instructions in this document. If you have questions, call your local Visonic
Technologies support representative.
This document is intended for trained system integrators, field service or
maintenance engineers that need to troubleshoot problems in the EIRIS
system, or configurations and processes.
LF Transmissions
Transmission Rate: Continuous bursts of LF transmissions (each about 12ms in duration).
Supervision RF Transmissions
Transmission Rate: 1 RF transmission (about 2ms in duration), 10 seconds apart.
Transmitted Message Type: 433.9 MHz Elpas Tag (badge) protocol including ID LF Exciter
code (ID code = OOODXX where XX is ID number of the LF exciter
Installation Guidelines
LF Exciters generate an omni directional magnetic
radiation pattern that is almost spherical in area. As
a consequence ceiling mounted Exciters may result
in the LF penetration of adjacent floors and rooms.
Each stand alone or master LF Exciter has a
detection range up to a 10ft/ 3m radius. For wider
area coverage, enhanced detection capability or
direction determination a master/slave configuration
should be used.
Optimizing Performance
General Placement: Position LF Exciters at least 30cm (12 inches) from any
metal barriers (such as signs/pillars/beams) in any direction.
Single Doors: To thoroughly cover an exit without penetrating excess areas, the
LF Exciter should be mounted on a wall, at waist height, next to the door.
Additionally, the LF field should be adjusted to cover only the width of the door.
Double Doors: A master/slave configuration may be used by mounting the master
exciter to the right of the double doors and the slave to the left of the doors.
Placement Warning
LF Exciters may not be mounted on metallic surfaces.
LF Exciters must be mounted as far away as possible from all other pieces of
equipment that may emit magnetic fields (such as large electrical motors, HVAC
and refrigeration compressors, etc.).
Main Circuit Board Components