Specification Sheet
© 2015 Elkay
SPEC08-01 (06/2015)
RATED FOR INDOOR USE ONLY
SPECIFICATIONS
Floor Water Cooler
Air Cooled Floor Mounted
Filtered Model LFAE(8,14,16,20)
GENERAL
Self-contained, electric refrigerated, oor model water cooler. Capacity of 50°F
drinking water, based upon 80°F inlet water. Shall include the WaterSentry
®
VII
1500-gallon capacity lter, certied to NSF/ANSI 42 and 53. Non-pressurized
tank system is standard. Non-pressurized water tank is located after bubbler
valve, so that tank is subject to line pressure only when valve button is pressed.
Unit shall be lead-free design which is certied to NSF/ANSI 61 and 372 and meets
Federal and State low-lead requirements.
STANDARD FEATURES
• Removable front panel offers easy accessibility to interior
• WaterSentry
®
VII 1500-gallon capacity Filtration System, certied to
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
• Extra deep basin minimizes splashing; with integral drain
• Exclusive Flexi-Guard
®
Safety bubbler
• Cooler Panel Finish options: Impact-resistant vinyl coating or stainless steel
• Rated for Indoor use
COOLING SYSTEM
• Compressor: Hermetically sealed, reciprocating type.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns.
• Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of
copper tubing. Fully insulated with EPS foam which meets Underwriters
Laboratories Inc. Requirements for self extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated
capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude requirements.
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical
components and water system are warranted for 12 months from date of
installation or 18 months from factory shipment, whichever date falls rst.
*Color code of (L) Light Gray Granite, (T) Sandalwood, or (S) Stainless Steel cooler panels.
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice.
Please visit elkay.com for the most current version.
This specication describes an Elkay product with design, quality and functional
benets to the user. When making a comparison of other producer’s offerings,
be certain these features are not overlooked.
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides structural integrity
• Cooler cabinet available as Light Gray Granite, Sandalwood, or Almond
Vinly Clad Steel or Stainless Steel (additional cost) construction
• Exclusive Flexi-Guard
®
Safety Bubbler utilizes an infused anti-microbial
pliable polyester elastomer to prevent accidental mouth injuries. Flexes
on impact.
• Cabinet design allows for ush to wall mounting or free standing
• Option for additional Glass Filler (ordered separately)
REPLACEMENT FILTER:
• 51299C (single)
CAPACITIES CHART
Glass Filler
(option) (F)
available
at extra cost
(order separately)
Requires
Factory prep to
receive glass ller
Model
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
Ship
Wt.
UL399 and
CAN/CSA 22.2
No. 120
Certied
NSF/ANSI
61 and 372
Certied
NSF/ANSI
42 and 53
Certied
Filter Only
LFAE8*1Z 115V / 60Hz 7.6 GPH 4.0 370 83 lbs. YES
• • •
LFAE8*2YJO 220V / 50Hz 6.3 GPH 2.0 370 83 lbs. –
++ • •
LFAE8*3YJO 220V / 60Hz 7.6 GPH 2.0 370 83 lbs. –
++ • •
LFAE14* 115V / 60Hz 13.5 GPH 7.2 665 82 lbs. YES
• • •
LFAE14*3YJO 220V / 60Hz 13.5 GPH 3.6 665 82 lbs. YES
++ • •
† LFAE16*3YJO 220V / 60Hz 15.5 GPH 2.8 510 83 lbs. YES
++ † NSF 61 ONLY •
† LFAE20* 115V / 60Hz 19.5 GPH 7.2 665 83 lbs. YES
• † NSF 61 ONLY •
† LFAE20*3YJO 220V / 60Hz 19.5 GPH 3.6 665 83 lbs. YES
++ † NSF 61 ONLY •
†EFA16 and EFA20 meet only the lead-free denition of NSF/ANSI 61. Rated
watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specic applications will determine the actiual watts
consumed per hour. Watts consumed will be based on number of people served