Installation Sheet

98638C (Rev. D - 05/16)
ER19*1D ER19*2D ER19*3D
23 "
584mm
8 1/8 "
205mm
4 1/4 "
114mm
10 1/4 "
2
60mm
5 1/8 "
130mm
1 9/16 "
40mm
A
B
1 1/4 "
32mm
C
4 7/8 "
123mm
1 3/4 "
44mm
25 3/4 "
654mm
TEMPERATURE
ADJUSTMENT
ELECTRICAL
ALTERNATE
ELECTRICAL
LOCATION
NOTICE: This water cooler must be connected to the water
supply using a dielectric coupling.
NOTE: It is important to insure proper ventilation. Allow a
minimum clearance of 12 inches (305 mm) in front and 3
inches (76mm) in the rear of the unit. If unit is to be installed
in an enclosure, allow the following clearances around unit - 1
inch (25mm) each side, 3 inches (76mm) in the rear, 3 inches
(76mm) inches above wall.
This chiller has been designed for use with potable water and
includes an o-ring seal on the drain plug. The tting should
be replaced if the unit is to be used with more aggressive
uids.
For use with photo processing applications, adjust
cold control to warmer settings.
ER191/ER192/ER193
Refrigeration Packages
Installation Instructions
LEGEND
A = 3/8" O.D. TUBE WATER OUT
B = 3/8" O.D. TUBE WATER INLET
C = 3/8" O.D. TUBE TANK DRAIN
USES HFC-134A REFRIGERANT
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.