Installation and Maintenance Manual Table of Contents Declaration of Conformity Association Recommendations for Safeguarding the Environment Explanation of Warning/Safety Icons Introduction Components Guide Product Specifications 2 2 3 3 4 5 6 Before You Begin – Requirements for Installation Mounting Dimensions Operating Environment Water Electrical Tools You Will Need Unpacking the Kit What’s in the Kit 7 7 8 8 8 9 9 10 Installing the Machine Operating the Touch Control Keypad Fontemagna Compact Only
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Declaration of Conformity D.M. 174 Materials compliant for contact with drinking water TA LY C NI 10 0 % M AD E T I F I C AT E ER I This unit is intended for the dispensing of drinking water, and so the materials that enter into direct contact with water meet the criteria for food-grade components pursuant to the current legislation.
ITPI rosso 032 c I TA LY C 10 IN T I F I C AT E ER 0 % M AD E D.M. 174 ITPI rosso 032 c Recommendations for Safeguarding the Environment Packaging materials The packaging materials are 100% recyclable. Please follow the local guidelines on waste disposal. For safety reasons keep the packaging material out of the reach and sight of children. Scrappage The Fontemagna Compact and Blubar Countertop water coolers are made using recyclable material.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Introduction The Fontemagna Compact and Blubar Countertop coolers bring contemporary style and state-of-the-art technology to commercial water dispensers. Fontemagna Compact combines precise pushbutton control with a sleek, minimalist design, while Blubar Countertop puts a modern spin on the traditional appeal of the handoperated tap.
Components Guide Blubar Countertop Removable top cover Fontemagna Compact Lockable top cover Touch Control keypad Tap – sparkling water Tap – still water Drip tray Drip tray Thermostat Ice bank inlet Ice bank overflow Water inlet CO2 inlet Power switch Power cord LED alarms No/low H20 pressure No/low CO2 pressure Machine stopped Fontemagna Compact Touch Control keypad Water inlet CO2 inlet Power cord Dispensing buttons – small serving large serving Power button Energy Saving button Cold sparkli
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Product Specifications Blubar Countertop Fontemagna Compact Cooling capacity gal/h (lt/h) Specification 20 (80) 20 (80) Continuous supply gal (lt) 12 (45) 12 (45) Cold water temperature 37.4°F – 50°F (3°C – 10°C) 37.4°F – 50°F (3°C – 10°C) Ice bank capacity gal (lt) 3.7 (14) 3.
Before You Begin – Requirements for Installation Mounting Dimensions Over counter (includes 4" clearance on sides and back) Blubar Countertop Depth 26.6" (678mm) Fontemagna Compact Depth 27.2" (691mm) Width 22.2"(564mm) Width 26.1"(663mm) Height 34.4" (874mm) Height 34.4" (874mm) Footprint: 14.2” wide x 22.6" deep 363mm x 574mm Footprint: 18.1" wide x 23.2" deep 460mm x 589mm Under counter Depth 3.88" (99mm) Width 3.25" (83mm) Height 12.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Operating Environment OO OO Install the machine in a clean, dry, well-ventilated room. It is designed to function correctly in environments with a temperature of 16°C to 32°C – Climatic Class N, (between 61°F and 90°F). Check that the water cooler is level, that it is on a surface that can support its weight and in an environment suitable for its size and use. OO Do not place the machine near a source of heat.
Tools You Will Need (2) 8" adjustable wrenches (1) 12" adjustable wrench (1) 12" pipe cutter (1) 10" adjustable pliers (1) universal screwdriver (1) wire cutting pliers Unpacking the Kit Remove the front panel (labeled FRONT) and cover of the wooden packing case. Remove the cardboard box and the internal protective packaging by sliding them up and over the top. Once you have unpacked the machine, check all components to ensure that they are not damaged.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual What’s in the Kit (1) 10' coil water tubing 3/8” OD (blue) (1) CO2 regulator (1) Blubar Countertop or Fontemagna Compact water cooler PLUS (1) supply hose 1/2 ips x 3/8 tube x 12” long (2) 3/8" – quick connect connector Top panel keys (1) water shutoff valve (1) water pressure regulator (1) external water filter (1) 10' coil CO2 tubing 1/4” OD (natural) (1) 3/8” x 1/4” quick connect connector NOTICE: CO2 source is not i
Installing the Machine CAUTION: Wear safety gloves when handling the machine. Metal edges are sharp, and touching them could result in minor or moderate injury. CAUTION: Machine weighs more than 100 lbs (45 kg) when the ice bank is filled. Lifting without proper support could result in minor or moderate injury. 1. Install external water filter and CO2 cylinder. 1. Use (2) Phillips head screws to mount bracket to under-counter wall. 2. User (4) Phillips head screws to mount filter head to bracket. 3.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual 2. Cut, size and connect water and CO2 piping to fit your installation. NOTICE: The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and 51 psi (0.35 MPa) maximum. If the inlet water pressure is higher than 51 psi, the water pressure regulator supplied must be used. NOTICE: An incoming flow rate of >1.0 gallon/minute is recommended for optimal quality of sparkling water.
3. Fill the ice bank in your machine. Blubar Countertop Fontemagna Compact 1. Insert piping from water supply (A) into ice bank inlet quick connect (B). 1. Unlock and open the top cover using the supplied key (A). E 2. Fill slowly until water reaches the maximum fill line on the overflow tube on the back side of the machine (C). 3. If water exceeds this level, water will flow from the drip tray on the front. 2.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual 4. Place the machine in its operating location. NOTICE: Ensure machine remains level while being lifted into place to prevent spillage from ice bank. 5. Connect external water and CO2 piping. Blubar Countertop Fontemagna Compact Water input Water input CO2 input Drip tray waste water CO2 input 6. Plug the machine into the wall socket and turn it on. 1. Connect the power cable to the nearest socket. 2.
7. Purge the water lines. 1. Place receptacle beneath tap to catch dispensed water. Discard water as necessary. Blubar Countertop Open both taps Fontemagna Compact Press and hold dispensing button 2. Allow water to run continuously until flow is clear of air. 3. Repeat for all taps. NOTICE: The "No/low CO2" error LED will flash on the Fontemagna Compact when dispensing begins. This is correct, as the CO2 connection has not been activated yet. This alarm can be ignored during this step. 8.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Operating the Touch Control Keypad Fontemagna Compact Only POWER H2O CO2 H2O H2O STOP CO2 CO2 MESSAGE STOP STOP To turn on the machine H2O SPARKLING ROOM TEMPERATURE COLD SPARKLING SPARKLING ROOM TEMPERATURE ROOM TEMPERATURE COLD COLD POWER POWER Note: The power button and dispensing button LEDs turn on.
POWER H2O CO H2O CO2 2 SPARKLING ROOM TEMPERATURE COLD STOP STOP ENERGY SAVING MESSAGE MESSAGE POWER To turn on Key Lock POWER H2O SPARKLING H2O CO2 CO2 SPARKLING Press and hold the Energy Saving button for more than 4 seconds, until the machine beeps once. CO2 H2O ROOM TEMPERATURE ROOM TEMPERATURE COLD STOP ENERGY SAVING MESSAGE CO2 SPARKLING COLD STOP ROOM TEMPERATURE MESSAGE COLD STOP Note: All of the button LEDs flash.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Programming the Touch Control Keypad Fontemagna Compact Only POWER POWER By default, the Fontemagna Compact dispenses a single 7 oz (0.2 liter) serving when the upper dispensing button is pressed, and a 34 oz (1 liter) serving when the lower dispensing button is pressed. You can change the default serving size by entering Programming Mode.
Routine Maintenance Daily OO Clean all external surfaces of the machine, the drip tray and the dispensing nozzles. NOTICE: It is recommended that all external components of the product be cleaned daily. It is recommended that you use dish soap, warm water and a clean, soft cloth to clean the product. DO NOT USE THE FOLLOWING PRODUCTS: Do not use ... chlorine bleach solutions on the product. Chlorides found in most soaps, detergents, bleaches and cleaners can attack stainless steel.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Twice a Year OO Replace the water filter after 6000 gallons or 6 months, or earlier depending on water quality. NOTICE: The filter head has an internal shutoff valve that stops the flow of water when the filter is removed. It is not necessary to shut off the water supply. 1. Turn used filter counterclockwise (to the left) 1/4 turn to remove from filter head. Pull filter away from head and remove. 2.
OO Set the thermostat COLDER 1. Set the thermostat between 5 and 6 to control the temperature of the ice bank. 1 2 3 OFF 2. If you want to avoid the formation of ice in the bank, turn the thermostat screw located on the back side of the machine at least 1/4 anti-clockwise. 4 7 6 5 1000002474 (Rev.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Troubleshooting Problem No water dispense Problem Low flow dispense Problem Sparkling water doesn’t come out Problem Water is not cold enough 22 Possible Cause Action To Take The main water valve is closed Open the valve The power switch is set to OFF Set the power switch to ON Malfunction in the ribbon cable connection/ spade connectors (Compact and Bridge only) Repair connection to main circuit board The water inlet
Problem Poor sparkling water quality Problem Volumetric is not working Problem Yellow (no CO2) alarm on Problem Red (no water) alarm on Problem Dripping water Possible Cause Action To Take Incorrect air gap in the carbonator Close the CO2 cylinder valve, pull up the ring on safety valve (on the carbonator bowl head) until all air gap is out Use of rinse aid or highly polished glass Avoid excessive use of rinse aid The CO2 regulator is set low Set the CO2 regulator between 55-60 psi (3.
Blubar Countertop and Fontemagna Compact Installation and Maintenance Manual Problem Noise/Vibration Possible Cause The ice bank is empty Fill the ice bank The agitator or the pump is not covered by water Fill the ice bank The copper tubing is vibrating against the cabinet Fix the position of the the tubing The fan is dirty Clean or replace it Contacting Customer Support Elkay Manufacturing Company 2222 Camden Court Oak Brook, IL 60523 800.416.
Fontemagna Compact DSFCF180UVK Blubar Countertop DSBCF180K Description X X 1000002622 Motor Fan 120x120x25 Motor Fan for the Carbonation Chiller, Fontemagna Compact, and Blubar Countertop models X X X 1000002623 Booster Pump Booster Pump for the Carbonation Chiller, Fontemagna Compact, and Blubar Countertop models X 1000002624 Level Control Level Control for the Carbonation Chiller and Blubar Countertop models X Fontemagna Bridge DSFB1UVK Carbonation Chiller DSFBF180K Product Name X P