Installation Sheet

PAGE 1 98421C (Rev. C - 09/17)
HDFF-EBPFR*A HDFF-BLEBPFR*A HDFF-BLREBPFR*A
Halsey Taylor Owners Manual
HDFF-EBPFR HDFF-BLEBPFR HDFF-BLREBPRF
Freeze Resistant Fountain
HDFF-EBPFR HDFFBLEBP - FR HDFFBLREBP - FR
Halsey Taylor Fountains are among the easiest to install Fountains on the market today. To assure you install
these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING
THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL,
AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future
reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s) contains
the Freeze Resistant Package(s) HTFRB1 that are installed on an interior heated wall. The interior space must
maintain a minimium temperature of 50° F (10° C). Refer to the Freeze Resistant Package for the rough-in
dimensions for installation.
INSTALLER
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.