Performance Data Sheet

FOR REPLACEMENT FILTER, PLEASE CALL 1.800.22ELKAY 97976C (Rev. L - 06/16)
ELKAY Aqua Sentry
Lead, Cyst, Chlorine, Taste& Odor, Atrazine, Lindane, and Particulate Class I Reduction Filter
Filter Part No. 56192C For LF2
FOR COMMERCIAL USE ONLY
PERFORMANCE DATA SHEET
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities
of this unit with your actual water treatment needs. It is recommended that, before pur-
chasing a water treatment unit, you have your water supply tested to determine your
actual water treatment needs.
NOTICE: Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certied for cyst
reduction may be used on disinfected waters that may contain lterable cysts.
This water lter should be installed and used in compliance with any state or local laws
and regulations.
CAUTION: Use on cold water line only. Do not allow installed lter to freeze.
NOTE: Performance will vary depending on local water conditions.
LIMITED WARRANTY
The ELKAY Aqua Sentry is warranted to be free from defects in material and work-
manship for a period of one year from the date of installation. Warranty is limited to
repair or replacement of defective component.
Your Authorized Representative
Buyer
Seller
Capacity
Flow Rate
Temperature
500 Gallons
6 Month Maximum
0.5 GPM
35°-100° F (2°-38° C)
RECOMMENDED USE CONDITIONS
Maximum Pressure 100 PSI (6.89 bar)
Minimum Pressure 20 PSI (1.4 bar)
Instructions For Installing Replacement Filters
1. Turn off water supply and dispense water to relieve water pressure.
2. Mount lter in a suitable location with water ow in direction indicated on lter.
This lter is most effective when installed so that water ows through the lter in
a downward direction. Do not support the lter using the inlet or outlet tubing. A
plastic snap-in bracket, p/n 56190C, is available that can be screwed onto a at
surface.
3. Connect the cold water supply to the lter through a shut-off valve and 1/4” O.D.
tubing (supplied by the installer). For ease of servicing, the shut-off valveshould
be located within easy reach of the lter.
Note: The inlet and outlet ttings supplied as a part of the lter are John
Guest ttings that accept 1/4” O.D. tubing. They may be used with copper,
semi-rigid nylon or polypropylene tubing with a rated working pressure
equal or greater than encountered in application. Do not use soft braided
tubing.
4. Caution: If supply pressure will ever exceed 100 psi, install a pressure
regulator to limit the inlet pressure to the lter to 20 - 100 psi range. To
make connections to the lter, push tube end in the ttings past the o-ring to
a positive stop - approximately 5/8”. Ends of tubing must be cut square
and free of burrs, sharp ends or scratches that could cut or nick the o-rings or
cause a leak.
5. Turn water supply on and check ttings for leaks.
6. Dispense approximately 1 gallon of water to ush any particulate from the lter.
LF2 - Aqua Sentry
NSF/ANSI 42,
NSF/ANSI 53 and
NSF/ANSI 372
certied