DD51-E DD51-E-RF Electronic position indicators OPERATING INSTRUCTION
DD51-E - DD51-E-RF Contents 1. Safety Instructions 1.1 Release Informations 2. System description 2.1 Wireless devices network 4 5 6 7 3. Assembly 7 4. Symbols on the display 8 5. Key function 8 6. Turning on the system 6.1 Turning off the system 7. Operating mode 10 10 10 7.1 Absolute / incremental measuring mode selection 10 7.2 Unit of measure selection 11 7.3 Setting the absolute reference 12 7.
DD51-E - DD51-E-RF 7.6 7.6.1 7.6.2 RF version (DD51-E-RF) Programming the network parameter (nEtid) and the channel parameter (nEtch) Targets 8. Programming mode Programming parameters with numeric values 8.2 Device parameters (in alphabetic order) 8.3 Main menu tree 8.4 Target menù tree 8.5 Parameter value 8.6 Addittional features 8.6.1 Reset 8.6.2 Test LCD 8.6.3 Release version 8.6.4 Password 15 15 16 16 8.1 16 9. Battery replacement 17 18 20 20 21 21 21 21 21 21 10.
DD51-E - DD51-E-RF 1 Safety Instructions The product has been designed and manufactured in accordance with the current regulations. The product leaves the factory ready for use and complies with the safety standards. To maintain the product in this state, it is necessary that it is assembled and used properly, in the closest compliance with this instruction manual and with the following specific safety precautions.
DD51-E - DD51-E-RF Setup / Commissioning In case of any abnormal behaviour (including change in operating conditions), the device must be switched off immediately. It is imperative to switch off power supply during any installation work at the equipment. Installation and commissioning by correspondingly trained and authorised staff only. After correct mounting and commissioning the device is ready for operation. Maintenance / Repair Switch off the power supply of the equipment before any action.
DD51-E - DD51-E-RF 2 System description DD51-E position indicators, with battery power supply, can be used on passing through shafts in any position to provide the reading of the absolute or incremental positioning of a machine component. Mechanical and electrical characteristics Power supply Lithium battery CR2450 3.
DD51-E - DD51-E-RF 2.1 Wireless devices network DD51-E-RF is compatible with the Elesa’s wireless network that allow electronic meters and indicators to communicate via radio with a PLC.
DD51-E - DD51-E-RF 4 Symbols on the display 1 2 3 4 5 6 1. 2. 3. 4. 5. 6. 6 Relative mode indicator Low battey level indicator RF connection indicator Unit of measure (mm / inch) Unit of measure (degrees) Target position indications 5 Key function WARNINGS! The keys’ icons are conventionally shown with the default display rotation set to 180. Key Operating mode Programming mode Keep pressed for 3 sec to enter the programming mode.
DD51-E - DD51-E-RF + Select the: Absolute measuring mode Incremental measuring mode It is possible to choose one of the following options (see the _ _ 0 _ _ voice of the menu – cap. 8.3): ArCLr [DEFAULT]: switching from ABS to REL the counter is set to zero. Ar: switching from ABS to REL the counter is not set to zero. OFF: the key is not assigned to any function in the operating mode. Digit increase / programming mode exit Press the key to select the unit of measure needed.
DD51-E - DD51-E-RF + Programmable with one of the following options (see the _ _ 0 _ 0 voice of the menu – cap. 8.3): L_OrG [DEFAULT]: the key combination sets the absolute value to the sum of the parameters Origin and Offset. OFF: the key combination is not assigned to any function in the operating mode. N/A To turn on the indicator, hold > then press the key After the start-up sequence the indicator will be ready to be used (see cap.
DD51-E - DD51-E-RF If the absolute measuring mode is selected no symbol is show on the display. __0__ It is possible to change the key function chosing one of the available otions in the menu voice _ _ 0 _ _ The available options are: - ArCLr (default): passing from ABS to REL the counter is set to zero. Ar: passing from ABS to REL the counter is not set to zero. In this case, the counter is set to zero by pressing + - .
DD51-E - DD51-E-RF 7.3 Setting the absolute reference After having selected the absolute measuring mode and stopped the shaft in the starting position or in the reference + position, press the key combination to set the absolute value to the sum of the values of the parameters OrG (absolute value of reference) and the selected OFFS (compensation value).
DD51-E - DD51-E-RF 7.4 Direct programming of the absolute reference value (origin) – of the compensation value (offset) – of the reading after one revolution (step) + The function of the keys combination allows direct access to the programming of one of the following parameters: Origin, Step or Offset.
DD51-E - DD51-E-RF To load a target: - select tArGE in the main menu (see cap. 8.3) - select LOAdt (see cap. 8.4) - select the wanted target value (LtG01 to LtG32) using the keys - press the key to select. - The value of the selected target is shown. - Press again to confirm or press the target selection list. to go back to WARNINGS! When a target is loaded the unit of mesure cannot be change. 7.5.
DD51-E - DD51-E-RF 7.5.2 Target display mode The menu voice _ _ _ _ 0 (see cap. 8.3) allows the user to choose one of the target following modes listed below: - dtArG (default): when a target is loaded, the display shows the actual absolute position and the indication to reach the target as explained before in cap. 7.5.1. Pressing the key the set target position is shown.
DD51-E - DD51-E-RF 7.6.2 Targets Using DD51-E-RF, target positions can be sent from the PLC to the indicators through the control unit. When a target is set, the behaviour is the sameas decribed in cap. 7.5. 8 Programming mode Press the key for 3 seconds to enter the programming mode. Depending on the setting of PASS parameter (see cap. 8.6.4), the system may require you to enter a password. Press the key to scroll through the list of parameters and selct the wanted one pressing .
DD51-E - DD51-E-RF 8.2 Device parameters (in alphabetic order) Standard value Parameter Description Available options dir Measurement direction Set direction of the positive axis --o counterclockwise rotation to increment the measure o-- clockwise rotation to increment the measure diSP Display orientation 0° 180° OFFS Offset Value See cap. 8.5 The system allows you to store up to 10 compensation values: OrG Reference value displayed at the start point See cap. 8.
DD51-E - DD51-E-RF Parameter Description Available options Standard value StEP Reading after one revolution 0.01; 100.00 001.00 _ _ _ _ 0 Display “t_Sho” visualization during target mode d_toG0: during the positioning the display show the distance from the target. Press the key to show the actual position of the indicator. d_toG0 d_tArG: during the positioning the display show the present position, press the key to show the target position to reach. tArGe Target options See cap. 8.5 0.0 8.
DD51-E - DD51-E-RF diSP 0° 180° SPEEd 300 600 1000 nEt id 00 ... 99 nEt ch ch 01 ... ch 36 rAdio PtoLL 0.01 ÷ 9.99 0.001 ÷ 0.393 See Cap. 8.4 tArGE Scrolling direction mm Inch 0____ * OFF ALL nodEG __0__ * ArCLr Ar OFF ____0 * OFF dtArG dtoGo 0___0 * __0_0 * P_OrG P_StP P_OFS OFF L_OrG OFF PASS See Cap. 8.6.4 rESEt See Cap. 8.6.1 LcdtS Fj.i.bb See Cap. 8.6.2 Release Version (see cap. 8.6.3) * See key definition 7 EN Models all rights reserved in accordance with the law.
DD51-E - DD51-E-RF 8.4 Target menù tree Scrolling direction StoP_t * PtG 01 PrOG_t See Cap. 8.5 ... PtG 32 See Cap. 8.5 LtG 01 LOAd_t ... LtG 32 * Displayed only if a target position is setted 8.5 Parameter value The parameter value depends on the unit of measure and resolution set. rES mm Inch deg 1 -9999 ÷ 9999 -0393 ÷ 0393 -9999 ÷ 9999 0.1 -999.9 ÷ 999.9 -393.7 ÷ 393.7 -999.9 ÷ 999.9 0.01 -99.99 ÷ 99.99 -99.99 ÷ 99.99 -99.99 ÷ 99.99 0.001 -9.999 ÷ 9.
DD51-E - DD51-E-RF 8.6 Addittional features 8.6.1 Reset To reset the device to the factory setup: - select the voice rESEt from the main menu (see cap. 8.3) - change the value from no to YES by pressing the key - press the key to confirm 8.6.2 Test LCD The LcdtS voice in the main menu allow to switch on all the display segments and symbols. 8.6.3 Release version As last voice in the main menu, starting with the “r” letter, are shown the release data of the device that can be scrolled pressing the key .
DD51-E - DD51-E-RF To simply remove the battery from the battery compartment, we recommend the use of a magnet. By replacing the battery in less than 5 seconds, all the measurement and settings wil not be lost. If more time is required and the display turns off, the settings of the device have to be set or verified again.