Maintenance Guide Part 3

NeTIS MAINTENANCE GUIDE – Version 1.1 71/139
8.1.1.2 IT configuration on the Switch
We will use the network management terminal to identify the link it number to the SWITCH
as well as the position in the SWITCH rack of COM3 in charge of the link: Position 1 to 12
for a standard chassis.
In CONFIGURATION / SETTINGS.
Right click on a BS then select Name Tc/Ts.
The window below appears. The G703 link configuration has a red border:
Junction: Link type
Voice/@IP: corresponds to the link it number
Board: corresponds to the location of the COM3/4 board in the SWITCH (Counting from the
SUPIP)
The Tx=Rx check box means that the dialogue it is identical for both sides of the link.
For the In and Out settings and the preferred direction refer to paragraph 9.1.2 Ring Network
The In and Out list zones must be filled in as in the window:
Ins: for the link the SWITCH 0/1 SW precedes the BS for consultation
Outs: for the link, no equipment succeeds the BS for consultation
Fault analyses and diagnosis

Summary of content (30 pages)