User's Manual

CONTROLS
WiFi: Enables WiFi capabilities.
SET: Use to set: date/time, alarm settings
(if WiFi has not been congured).
UP: Adjusts setting up in SET menu.
DOWN: Adjusts setting down in SET menu
CHANNEL SELECT: Selects which channel to
display or select all channel view mode to view all
channels.
PLAY/PAUSE: In single channel view mode,
select second line display: current time, current
minimum, current maximum, alarm setting lower
limit, alarm setting higher limit.
C/F: Selects temperature unit
CLEAR: Press to clear current min/max values.
Note: “WiFi enabled” is indicated by the ashing WiFi
symbol. It also indicates that WiFi network needs to be
congured.
indicates an alarm of unsuccessful data
transmission to cloud server.
Press button to clear alarm, or alarm will clear
automatically upon next successful transmission.
DEVICE SPECIFICATIONS:
Temperature Range: 0 to 55°C (32 to 131°F)
Humidity Range: 0 to 95% (non-condensing)
Temperature/Humidity Sampling rate: 9 seconds
Barometric Pressure Range: 500 to 1100 mb
Barometric Pressure Sampling rate: 5 minutes
Default WiFi Transmission Frequency: 15 minutes
Maximum number of Stored Records: 672 (7 days if set
to 15 minutes interval)
Max. Stored Alarms: 100
Battery: 4 AAA Alkaline battery
DISPLAY MODES—SINGLE CHANNEL MODE
LCD displays information on channel 1, 2, or 3. Scroll
through: current time -> current minimum / current
maximum -> alarm setting minimum / alarm setting
maximum -> current time.
Scrolling interval: 3 seconds.
Press CHANNEL SELECT button to select the desired
channel, or all channels.
Channel 1 displays humidity; Channel 2 displays
temperature; channel 3 displays pressure.
To pause scrolling, press PLAY/PAUSE. To resume
scrolling, press PLAY/PAUSE again. To fast forward,
press PLAY/PAUSE to move to next item.
Once desired information is displayed, press Play/
Pause button again to pause scrolling, otherwise
second line resumes scrolling.
ALL CHANNEL MODE
To view all Channel 1, 2, and 3. Press CHANNEL
SELECT button to select all channels.
CH123 symbol will appear on display.
SELECTING CHANNEL
While the device is not in SETUP Mode, press
Channel/Select button to select channel.
If Channel 1 (HUMIDITY) is selected, CH1 symbol will
appear on display.
If Channel 2 (TEMPERATURE) is selected, CH2
symbol will appear on display.
If Channel 3 (PRESSURE) is selected, CH3 symbol will
appear on display.
If in all channel view mode, the rst line displays
Channel 1, second line Channel 2, and third line
Channel 3. CH123 symbol will appear on display.
SENSORS
A dongle with temperature, humidity, and pressure
sensor is provided with unit. Used to measure and
monitor ambient temperature, ambient humidity, and
pressure.
IMPORTANT: PLUG DONGLE INTO DEVICE BEFORE
INSERTING BATTERIES AS THIS WILL CAUSE
INCORRECT READINGS.
If dongle sensor was plugged into device after batteries
were installed, remove dongle sensor until LCD reads “-
-.- -” on CH1 and CH2 (about 10 seconds) and then plug
dongle back into device.
CLEAR CURRENT MINIMUM/MAXIMUM MEMORY
1. Press CHANNEL SELECT to select probe channel to
be cleared.
2. CH1 will clear Channel 1; CH2 will clear Channel 2;
CH3 will clear Channel 3 and in all channel mode
CH123 will clear Channels 1, 2, 3.
3. Press CLEAR button to clear current minimum and
maximum readings.
4. Each clear of the Minimum/Maximum memory will
also trigger a transmission of current reading(s) to
TraceableLIVE service, if connected. This will display
in EVENT HISTORY with label “DEVICE CHECK”.
DEVICE SETUP
SCENARIO 1: WiFi is disabled. All settings are
congurable.
1. Press and hold SET button for 3s to enter setup
menu.
2. The rst ashing number is the year date setting.
Press the UP or DOWN arrow to set to the current
year. Press the PLAY/PAUSE button to save and
proceed to the next setting.
3. Continue to set the remaining parameters (Month-
>Day->Hour->Minute->Time Format (12H/24H)
Pressure Unit ->Channel 1 Minimum Alarm-
>Channel 1 Maximum Alarm->Channel 2 Minimum
Alarm->Channel 2 Maximum Alarm->Channel 3
Minimum Alarm ->Channel 3 Maximum Alarm->Local
Altitude Setting ->Alarm Repost Enable/Disable ->
Alarm Repost Interval Setting (if Alarm Repost is
enabled). Press PLAY/PAUSE to proceed to the
next parameter. Pressing PLAY/PAUSE after the last
parameter is set will exit setup mode.
SCENARIO 2: WiFi is enabled. Alarm settings are not
congurable on the device and can only be set through
the TraceableLIVE cloud service interface.
1. Press and hold the SET button for 3 seconds to enter
setup menu.
2. The rst ashing number is the year date setting.
Press the UP or DOWN arrow to set to the current
year. Press the PLAY/PAUSE button to save and
proceed to the next setting.
3. Continue to set the remaining parameters (Month-
>Day->Hour->Minute->Time Format (12H/24H).
Pressure Unit -> Alarm Repost Enable/Disable ->
Alarm Repost Internal Setting (If Alarm Repost is
enabled). Press PLAY/PAUSE to proceed to the next
parameter. Pressing PLAY/PAUSE after the last
parameter is set will exit setup mode.
NOTE: Setting the time while WiFi is enabled is only
intended for initial device setup. Once connected to the
TraceableLIVE service, the device time will be synchro-
nized daily for selected time zone in TraceableLIVE.
ALARM
1. If an alarm triggers, the LCD will automatically display
the alarming channel, and the temperature reading, HI
ALM or LO ALM symbols ash. If temperature is below
low alarm setting, MIN symbol ashes; if temperature
is above high alarm setting, MAX symbol ashes.
Audible alarm will continue beeping for 30 seconds
and will beep once every 15 seconds until alarm is
acknowledged by pressing the CLEAR button.
2. If alarms trigger on both channels, the LCD will display
Channel 1.
3. Use CHANNEL SELECT to select which channel to
display. If the displayed channel is not alarming, the
LCD will not ash, but the buzzer will remain active.
4. If an alarm is triggered, the second line of the LCD will
no longer scroll, and if the device is in single channel
display mode, the alarming set point will display on the
second line.
5. To clear an alarm, press the CLEAR button. The LCD
will stop ashing, buzzer will stop beeping, and LCD
second line will resume scrolling.
6. Once an alarm is triggered, the device will post the
alert to the TraceableLIVE
®
service immediately. If
connectivity is currently lost, the device will store the
alarm until it reconnects. Devices can store up to 100
alarm events in internal memory.
DISPLAYING °F OR °C
To display the temperature readings in Fahrenheit (°F)
or Celsius (°C)
on device, press the C/F button.
Note: Changing from °C to °F in the TraceableLIVE
®
Cloud, will not change readings on device (see
TraceableLIVE Cloud instructions).
Note: Changing from °C to °F on device, will not
change the readings in the TraceableLIVE
®
cloud.
DISPLAYING MB OR inHG
Select mb or inHg in SETUP mode.
Note: Changing from mb to inHg in the
TraceableLIVE
®
Cloud, will not change readings on
device (see TraceableLIVE Cloud instructions).
Note: Changing from mb to inHg on device, will not
change the readings in the TraceableLIVE
®
cloud.
CONFIGURE WiFi NETWORK: AP PROVISIONING
Press WiFi button to enable WiFi function. If it is rst
time enabled, WiFi symbol will ash.
Press and hold WiFi button for 3 secs until device
displays “AP”. To abort, press and hold WiFi button.
Press WiFi button again, the device will display “AP
UAIT” (AP WAIT).
After 5 to 10 seconds, “AP rEAdy” (AP ready) will
appear on display. To abort, press and hold CLEAR
button until the device restarts.
NOTE: WiFi conguration will be cleared if aborted at
this stage.
Use a mobile phone or wireless capable laptop,
connect to Network ID “CC6529-XXXX”, where xxxx is
last 4-digit of the device’s serial number (S/N).
Open a web browser, type 192.168.1.1, the setup
webpage will appear:
From Add Proles section, from the drop-down
list, select the intended Network ID, and then input
security type, password. Please double check these
information are correct. Security type is default to
WPA2.
Or if the intended Network ID is not shown in the list,
scroll to the last item of the list “Other, please specify:”
and select. A new input box is shown:
Type Network ID in the box, and then select security
type and type password;
Click Add button.
If network is congured successfully, the device
reboots, and is ready to use.
If network conguration fails, the device displays “Err”,
and then press CLEAR button, the device reboots.

Summary of content (2 pages)