MANUAL CARAVAN RA/RM-2D 0402 RM 4601 RM 4801 Deutsch Seite 3 English page 12 Français page 21 822 70 89-00
OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS ........................... 13 It is important to read through these instructions carefully before using the refrigerator.
OPERATING INSTRUCTIONS CONTROLS 5. When the flame lights, the sparking stops automatically and the lamp stops flashing. 6. Keep the knob (C) depressed for another 10-15 seconds to activate the flame failure device, then release it. If the lamp start flashing again, repeat step 4-6. To terminate gas operation, turn the knob (A) to "OFF" position. 230-240 V operation Before taking the refrigerator into operation, check that the voltage stated on the data plate is the same as the main voltage in use.
The frozen food compartment is intended for the storage of frozen food and for making ice. It is not suitable for freezing items of food. Never put bottles or cans of fizzy drinks in the frozen food storage compartment as they may burst when freezing. Most kinds of frozen food can be stored in the frozen food compartment for about a month. This period of time may vary, however, and it is important to follow the instructions on the individual packages.
The sealed cooling system must not be opened, since it contains corroding chemicals under high pressure. MAINTENANCE Always turn to a qualified service technician who is familiar with LP gas systems and refrigerator. We recommend that a service technician check the refrigerator once a year. • • • • Check all connections in the LP gas system for gas leaks. Connections can be tested for leaks using a soap solution.
2 FIG. 4 FIG. 2 Seal the opening for the screws with aluminium tape. Replace the top decoration panel. Make sure the tabs snap back into the holes in the hinge plate. Securing the refrigerator C. Two screws installed in the rear base. See fig. 5. After the refrigerator is put in place, (insuring a combustion seal at the front frame), the refrigerator is to be secured in the enclosure with six screws. The screws have to be installed in the following order: A.
VENTILATION OF THE UNIT NOTE: Wood Strip MUST be in place Minimum ventilation height Minimum ventilation height Condenser FIG. 6a FIG. 6b Ventilation heights Model Minimum ventilation heights in mm. Installation with upper Installation with roof vent and lower side vent. and lower side vent. RM 4601 1760 1515 RM 4801 1900 1670 At high ambient temperatures the refrigeration unit will only perform adequately when properly ventilated.
connecting permanently operating appliances of this type in the United Kingdom). All connectors etc. should be of a type specifically designed for the type and diameter of the connection pipe used, and screwed joints should be sealed with a joining compound approved for use with bottled gas. The gas supply pipe should be connected to the gas inlet pipe (outside diameter 8 mm) by means of a suitable gas-tight compression fitting, e.g. olive.
TECHNICAL DATA RM 4601 Overall dimensions, refrigerator Height (incl. controls) ........... 1427 Width ................................... 632 Depth (incl. handle).............. 668 Recess dimensions Height .................................. 1415 Width ................................... 607 Depth ................................... 620 Capacity Gross ................................... 186 Net ....................................... 171 frozen food compt. ............... 47 Weight (without packaging) ..
Wiring diagram RM 4601, RM 4801 20