electrolux 3 EN IMPORTANT SAFETY INFORMATION 4 YOUR APPLIANCE 5 OPERATING INSTRUCTIONS 6 MAINTENANCE AND CLEANING 8 SOMETHING NOT WORKING 10 GUARANTEE/CUSTOMER SERVICE 11 GUARANTEE CONDITIONS 12 INSTALLATION INSTRUCTIONS 14 ELECTRICAL CONNECTIONS 15 INSTALLING THE COOKER HOOD 16 EN Welcome to the world of Electrolux Thank you for choosing a first class product from Electrolux, which hopefully will provide you with lots of pleasure in the future.
electrolux IMPORTANT SAFETY INFORMATION IMPORTANT SAFETY INFORMATION EN These warnings are provided in the interests of your safety. Ensure that you understand them all before installing or using this appliance. Your safety is of paramount importance. If you are unsure about any of the meanings of these warnings contact the Customer Care Department. Installation • Any installation work must be undertaken by a qualified electrician or a competent person.
YOUR APPLIANCE AND OPERATING INSTRUCTIONS electrolux 5 YOUR APPLIANCE EN Components Ref.Q.ty Product Components 1 1 Hood Body, with: Controls, Light, Blower, Filters 9 1 Reducer Flange ø 150-120 mm 10 1 Adapting ring ø 120-125 mm Q.
electrolux YOUR APPLIANCE AND OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. EN To obtain the best performance it is advisable to switch on the hood a few minutes before you start cooking and leave it running for approximately 15 minutes after finishing. Cooker Hood Controls The cooker hood functions are controlled by slide switches, located centrally in the front edge of the metal grille panel. L.
electrolux 7 To Operate Select the required functions. The appliance can be installed to recirculate or extract contaminated air. The cooker hood is more effective when used in the extraction mode. Extraction In the extraction mode the contaminated air enters the cooker hood, passes through the grease filter and out through the ducting to the atmosphere.
electrolux MAINTENANCE AND CLEANING MAINTENANCE AND CLEANING Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. EN The cooker hood must be kept clean, as a build up of grease or fat can be a fire hazard. The external surfaces of the hood should be cleaned regularly. Wipe the cooker hood frequently with warm soapy water using a mild detergent. Dry thoroughly after cleaning. Always wear protective gloves when cleaning the hood.
electrolux 9 Metal Grease Filters: The metal grease filters can be machine washed in a dishwasher, or hand washed in hot water and a mild detergent or liquid soap. To Remove/Replace the Metal Filters 1.Press against the metal actuator to release the spring catch. 2.Drop the front edge of the cassette down as illustrated opposite and lift the back edge out of the rear guide. 3.To refit insert the back edge of the cassette into the rear guide and push up the front edge until the spring catch engages.
electrolux SOMETHING NOT WORKING SOMETHING NOT WORKING If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following checks. EN Symptom The cooker hood will not start The cooker hood is not working effectively The cooker hood has switched off during operation If after all these checks, the fault persists, contact your local Service Force Centre, quoting the model and serial number.
GUARANTEE/CUSTOMER SERVICE electrolux 11 GUARANTEE/CUSTOMER SERVICE Standard guarantee conditions We, Electrolux, undertake that if within 12 months of the date of the purchase this Electrolux appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our option repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: • The appliance has been correctly installed and used only on the electricity supply stated
electrolux GUARANTEE CONDITIONS GUARANTEE CONDITIONS Customer Care For general enquiries concerning your Electrolux appliance, or for further EN information on Electrolux products please contact our Customer Care Department by letter or telephone at the address below or visit our website at www.electrolux.co.
electrolux 13 www.electrolux.com à Albania +35 5 4 261 450 Rr. Pjeter Bogdani Nr. 7 Tirane Belgique/België/Belgien +32 2 363 04 44 Bergensesteenweg 719, 1502 Lembeek Česká republika +420 2 61 12 61 12 Budějovická 3, Praha 4, 140 21 Danmark +45 70 11 74 00 Sjællandsgade 2, 7000 Fredericia Deutschland +49 180 32 26 622 Muggenhofer Str. 135, 90429 Nürnberg Eesti +37 2 66 50 030 Mustamäe tee 24, 10621 Tallinn España +34 902 11 63 88 Carretera M-300, Km.
electrolux INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way.
ELECTRICAL CONNECTIONS electrolux 15 ELECTRICAL CONNECTIONS DOUBLE INSULATED DO NOT EARTH Electrical Requirements Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).
electrolux INSTALLING THE COOKER HOOD INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the EN event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood.
electrolux 17 When installed between adjoining wall cabinets, the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm. If the height of the wall cabinet is less than 450mm, a gap of 50mm must be maintained either side of the hob. This cooker hood must not be installed above a cooking appliance with a high level grill.
electrolux The hood is fixed using the holes located in the rim around the base of the casing visible when the inlet grille is in the open position. Support the grille panel with one hand EN and draw down on the two grey handles (A) which are located on each side of the grille with the other hand. Raise the hood into the cut out and mark the positions for the fixing screws. Pilot drill the fixing holes and fit the hood.
electrolux 19 Extraction The charcoal filters are not required in this mode and should be removed. To do this reverse the procedure described in Inserting the ‘Charcoal Filters’. Ducting The ducting used must be fire retardant 125mm (5”) in diameter. If possible duct through the wall at the rear of the canopy or wall cabinet. For the best performance use the shortest possible duct run and the minimum number of bends.
electrolux 20
electrolux 21
electrolux 22