Installation Guide

7
Installation Instructions
WARNING
ELECTRICAL SHOCK HAZARD
Do not operate dryer without terminal cover in place. A
correctly installed terminal block cover also acts a qualified
strain relief for the power cord.
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
1 Turn off power supply to outlet.
2 Remove the three screws securing the terminal block
access cover in the upper corner on the back of the
dryer.
3 Using an UNPLUGGED, UL-approved, 30 amp. power
cord, NEMA 10-30 type SRDT, attach the neutral (center
wire) conductor to the SILVER colored center terminal on
the terminal block. Tighten the screw securely.
5 Reinstall the terminal block cover.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing could
result in personal injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor at
connections.
IMPORTANT
If moving dryer from a 4-wire system and installing it now
in a 3-wire system, move the internal ground wire from
the center terminal back to the GREEN screw under the
terminal block.
neutral
terminal
DO NOT move
internal ground in
a 3-wire system!
access cover
screw
terminal cover
DO NOT
REMOVE
THIS SCREW
access cover
screw
access cover
screw
line 2 - L2
(BRASS terminal)
internal ground
(GREEN screw)
route cord here
neutral - N
(SILVER terminal)
line 1 - L1
(BRASS terminal)
4 Attach the remaining two power cord outer conductors
to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.
NOTE
Terminal screws were shipped from the factory temporarily
attached inside the access cover.