Installation Requirements
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES REAR TOP FRONT
Alcove 0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
Under Counter 0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
Clearance requirements
Closet Installation
NOTE
Because of potentially inconsistent voltage capabilities,
the use of this dryer with power created by gas powered
generators, solar powered generators, wind powered
generators or any other generator other than the local utility
company is not recommended.
NOTE
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).
Electrical requirements for electric dryer
3-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R
receptacle to be located so the power supply cord is
accessible when the dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements”
in Electrical Installation section.
The dryer MUST employ a 3-conductor power supply cord
NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30
amp, with 3 open end spade lug connectors with upturned
ends or closed loop connectors and marked for use with
clothes dryers. For 3-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
The dryer MUST employ a 4-conductor power supply
cord NEMA 14-30 type SRDT or ST (as required) rated
at 240 volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends or closed loop
connectors and marked for use with clothes dryers. For
4-wire cord connection instructions see ELECTRICAL
CONNECTIONS FOR A 4-WIRE SYSTEM.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
IMPORTANT
This dryer is internally grounded to neutral unless it was
manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance
is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through
the neutral link is prohibited for: (1) new branch circuit
installations, (2) mobile homes, (3) recreational vehicles,
and (4) areas where local codes do not permit grounding
through the neutral.
Manufactured or mobile home installation
Installation MUST conform to current Manufactured Home
Construction & Safety Standard, Title 24 CFR, Part 32-80
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard CAN/
CSAZ240 MH.
CIRCUIT - Individual 30 amp. branch circuit fused with 30
amp. time delay fuses or circuit breakers. Use separately
fused circuits for washer and dryer. DO NOT operate a
washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 208-240 volt, single
phase, 60 Hz, Alternating Current.
If installing the dryer in a closet, the unit must only be
operated with the door in the open position to allow correct air
circulation. See Use and Care Guide for more information.