Operating and assembly instructions AH 360-120 Extractor hood
AH 360-120 Preface 1. Important notes 1.1 For your safety 1.2 Operating for the first time 1.3 About use 2. Structure and operating principle 2.1 Structure of the appliance 2.2 Accessories/special accessories 2.3 Operating principle 3. Operation 3.1 Switching on and off 3.2 Special functions 4. Cleaning and care 5. Maintenance 6. Assembly instructions 6.1 Technical data 6.
Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – effective extraction thanks to the so-called “Coanda effect” – low operating noise To ensure that you will be able to use this appliance in all its diversity, read through the operating and assembly instructions conscientiously before operating it for the first time. The instructions contain important notes on use, installation and maintenance of the appliance.
1. Important notes 1.1 For your safety Damaged appliances must not be operated. Connecting cables must not come into contact with hot cooking surfaces. Do not operate the extractor hood without inserted lamps. Never operate the appliance without a grease filter. Hazardous or explosive substances and vapours must not be extracted! The user is responsible for expert use and the perfect condition of the appliance. Only ever operate the appliance under supervision.
1.2 Operating for the first time 1.3 About use Before operating the appliance for the first time, please pay attention to the following notes: The appliance is intended solely for use in the household and must not be put to any other uses. The appliance must be installed and connected by a specialist before it is operated for the first time. In the event of malfunctions, first of all check the household fuses.
2. Structure and operating principle 2.1 Structure of the appliance 1 3 2 4 1 2 3 4 Display Glass plates Air duct Control panel Fig. 2 5 10 11 12 Fig. 3 6 7 8 9 13 14 15 5 6 7 8 9 10 11 12 13 14 15 Grease filter key Ventilation level display “Coanda level” key “Light” control knob “Ventilation level” control knob “After-running” key “After-running” symbol “Grease filter saturation” symbol “Coanda level” symbol “Intensive level” symbol “Intensive level” key 2.
2.3 Operating principle This extractor hood swiftly and silently extracts all odours produced while cooking. You can set different intensity levels depending on the intensity of odours. The fan in the extractor hood sucks in the kitchen vapours and passes them through the grease filter to outdoors. The grease filter absorbs the greasy components in the kitchen vapours (see Fig. 4). Fig. 4 The “Coanda effect” Kitchen vapours are extracted even better with the “Coanda effect”.
3. Operation 3.1 Switching on and off Switching on – Turn the “Ventilation level” control knob to the ventilation level you require (Fig. 6). – The set level is displayed. After a power failure, the extactor will not go on again automatically. You can recommence operation by turning a knob or by pressing any key. Fig. 6 Switching off 0 – Turn the “Ventilation level” control knob to the 0 position (Fig. 7). 0 1 – The set level 0 is displayed for a few seconds.
3.2 Special functions Intensive level You should select the intensive level when browning and frying in an open pan. 0 0 1 2 Switching on: (Fig. 9) – Turn the control knob to a ventilation level (1-3). – Press the intensive level key. The intensive level symbol appears on the display. The previously selected ventilation level flashes on the display. After a few minutes, the appliance switches back automatically to the previously selected ventilation level. or – Press the intensive level key.
4. Cleaning and care Caution! Over-greased filters are a fire risk! Pay attention to cleaning the grease filter on a regular basis. Cleaning the grease filters: The (Grease filter saturation) symbol flashes on the display after an operating time of 30 hours. Flashing of this symbol signals to you that the grease filters have to be cleaned. The grease filters can be cleaned at any time, even if the (Grease filter saturation) symbol does not flash. The metal filters can be removed easily for cleaning.
Cleaning the glass plates Apply commercially available window cleaning agent with a soft, moist cloth. To facilitate cleaning, you can detach the glass plates as follows: Detach the grease filters. In the extractor hood, you will find two openings on the upper side through which you can lift the glass plates singly with a blunt object (e.g. handle of a wooden spoon) to detach them with greater ease.
5. Maintenance First disconnect the appliance from the mains before carrying out any repairs. In the event of malfunctions, first of all check the household fuses. If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or your responsible Gaggenau after-sales service. Specify the appliance type (see rating plate). Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance.
6. Assembly instructions 6.1 Technical data 6.2 Installation Weight: 41 kg without ventilation duct The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. Dimensions: 1198 x 560 mm Electrical connection Pay attention to the rating plate data. The mains connecting cable must at least correspond to the type H 05 VV-F G 0,75.
Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Depending on the ceiling height, the following duct units are at your disposal for exhaust air operation: Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – LK 360-020: Ventilation duct for a ceiling height of 2.66 - 3.
Proceed as follows: 15 300 310 230 Important: Before marking the securing holes, make sure that no electricity or water lines or other lines are laid at the drilling points in the wall. Important: There are two handles on top of the hood. Only carry the hood using these handles. Do not lift the hood by the stainless steel side panels or the aluminium front panel. 76,5 270 518,5 120 960 min. 650 mind. 650electric Elektro min.750 750Gas gas mind. Fig.
– Secure the hood to the wall using the 4 screws b (Fig. 18). – Establish the pipe connection. – Establish the electrical connection. – Extract the protective file from the chimney paneling. Note: Avoid damaging the sensitive stainless steel surfaces. – Fit the top of the chimney into the base. Make sure that the fastening holes on the side are at the top. Fig. 18 – Secure the top duct unit with 2 screws on the ceiling holder. – Pull the shoe down into its final position (Fig. 19).