OWNER’S MANUAL BEDIENUNGSANLEITUNG
CONTRACTOR PRECISION SERIES CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scope of Delivery and Warranty . . . .
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficent magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance. 1.
CONTRACTOR PRECISION SERIES 1 Introduction 1.1 Welcome Thank you for choosing an Electro-Voice CPS series amplifier. Please take time to consult this manual so that you can understand all the features built into your Electro-Voice amplifier and fully utilize all its performance capabilities. 1.2 Unpacking and Inspection Carefully open the packaging and take out the power amplifier. Inspect the power amp’s enclosure for damages that might have happened during transportation.
CONTRACTOR PRECISION SERIES WARNING: The terminals marked with are hazardous live and the external wiring connected to these terminals requires installation by an instructed person or the use of ready-made leads of cords. HF-Interference (FCC Information USA) 1. IMPORTANT: Do not modify this unit! Changes or modifications not expressly approved by the manufacturer could void the user‘s authority, granted by the FCC, to operate the equipment. 2.
CONTRACTOR PRECISION SERIES 2 Installation 2.
CONTRACTOR PRECISION SERIES 2.2 Operating Voltage The power amplifier receives its power supply via the MAINS IN connector. Only the provided power cord may be used. During installation, always separate the power amplifier from the mains. Connect the power amplifier only to a mains network, which corresponds to the requirements indicated on the type plate.
CONTRACTOR PRECISION SERIES CAUTION: Blocking/closing the power amp’s ventilation louvers is not permissible. Without sufficient cooling/ventilation, the power amplifier may automatically enter protect mode. Keep ventilation louvers free from dust to ensure unhindered airflow. Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat radiating devices.
CONTRACTOR PRECISION SERIES 2.9 Selecting the Mode Of Operation and Audio Output Cabeling The MODE switch on the power amp‘s rear panel defines how the audio inputs handle the input signals. Possible settings are DUAL, PARALLEL or BRIDGED. DUAL In DUAL mode, the two channels of the power amplifier work independent from each other. This mode of operation is being used for all 2-channel applications, like stereo operation.
CONTRACTOR PRECISION SERIES 2.10 Audio Input Cabeling Inputs are electronically balanced. Whenever possible, using balanced audio signal feeds at the input of the power amplifier is always preferred. Unbalanced connections should only be used if the cables are very short and no interfering signals are to be expected in the vicinity of the power amplifier. In this case, bridging the screen (shielding) and the pin of the inverting input inside of the connector is mandatory.
CONTRACTOR PRECISION SERIES 3 Operation 3.1 Volume Control In DUAL and PARALLEL mode, the level controls LEVEL on the power amp’s rear panel are used to control the amplification of the corresponding channel. Turning the control to the right increases and turning it to the left decreases the volume. In BRIDGED mode operation, the output volume of the power amp is only controlled by the CH 1 level control. Any changes in the setting of the CH 2 level control are ignored. 3.
CONTRACTOR PRECISION SERIES 3.3 Standby Mode (POWER REMOTE) POWER REMOTE provides a simple way to remotely power-on/off the power amplifier. The POWER REMOTE function is only useful for appliances not employing a Remote Control Modul. Controlling CPS amplifiers with Remote Control Module installed per POWER REMOTE is not recommended. Leaving the pins of POWER REMOTE socket open the appliance power is switched on. When connecting the pins the applicance enters standby mode. 3.
CONTRACTOR PRECISION SERIES 4 Options Installing one of the optionally available extension modules in the extension slot on the rear panel lets you expand the power amp’s functional range. As an example, the following paragraphs describe the RCM-810 Remote Control Module. Please read and follow the instructions provided in the documentation that you have received together with each extension module. 4.
CONTRACTOR PRECISION SERIES HIGH LOW Address HIGH LOW Address 0 0 Stand-alone 8 0...F 128...143 0 1...F 1...15 9 0...F 144...159 1 0...F 16...31 A 0...F 160...175 2 0...F 32...47 B 0...F 176...191 3 0...F 48...63 C 0...F 192...207 4 0...F 64...79 D 0...F 208...223 5 0...F 80...95 E 0...F 224...239 6 0...F 96...111 F 0...A 240...250 7 0...F 112...127 F B...F reserved Table 4.
CONTRACTOR PRECISION SERIES Illustration 4.2: Pin-assignment of CAN jack and CAN plug Colour Pin Name 2 CAN_GND 4 CAN_H (+) Blue 5 CAN_L (-) Blue striped T568A T568B Green Orange Table 4.3: Overview CAN plug 4 CONTROL PORT The CONTROL PORT of the RCM-810 provides two control inputs, two control outputs and reference connections for +5V and ground. The control inputs are configurable via IRIS-Net™. They can be used for example for switching between power on / standby modes.
CONTRACTOR PRECISION SERIES Owner‘s Manual 17
CONTRACTOR PRECISION SERIES Specifications/Technische Daten Amplifier at rated conditions, both channels driven, 8 Ω load, unless otherwise specified. CPS2.4 Load Impedance Maximum Midband Output Power THD = 1%, 1 kHz, Dual Channel Rated Output Power THD < 0.1%, 20 Hz...20 kHz CPS2.6 CPS2.9 8Ω 2Ω CPS2.
CONTRACTOR PRECISION SERIES 5.1 Mains Operation & Resulting Temperature CPS2.4 Umains in V Imains in A Pmains in W Pout in W Pd in W1 BTU/hr2 230 0.3 38 0 38 130 Max. Output Power @ 8 Ω3 230 4.9 800 540 260 887 Max. Output Power @ 4 Ω 230 8.0 1450 900 550 1877 1/3 Max. Output Power @ 4 Ω3 230 5.1 900 300 600 2047 1/8 Max. Output Power @ 4 Ω3 230 3.4 550 112.5 437.5 1493 1/8 Max. Output Power @ 4 Ω4 230 3.0 470 112.5 357.5 1220 1/8 Max.
CONTRACTOR PRECISION SERIES CPS2.9 Umains in V Imains in A Pmains in W Pout in W Pd in W1 BTU/hr2 230 0.4 46 0 46 157 Max. Output Power @ 8 Ω3 230 9.4 1740 1100 640 2184 Max. Output Power @ 4 Ω 230 15.3 2810 1800 1010 3446 1/3 Max. Output Power @ 4 Ω3 230 8.7 1450 600 850 2900 1/8 Max. Output Power @ 4 Ω3 230 3.6 560 225 335 1143 1/8 Max. Output Power @ 4 Ω4 230 3.6 540 225 315 1075 1/8 Max. Output Power @ 4 Ω 253 4.
CONTRACTOR PRECISION SERIES 5.
CONTRACTOR PRECISION SERIES 5.
AMERICAS EUROPE, AFRICA & MIDDLE-EAST ASIA & PACIFIC RIM Bosch Security Systems, Inc. 12000 Portland Ave South Burnsville, MN 55337, USA USA-Phone:1-800-392-3497 Fax: 1-800-955-6831 Canada-Phone: 1-866-505-5551 Fax:1-866-336-8467 Latin America-Phone: 1-952-887-5532 Fax: 1-952-736-4212 Bosch Sicherheitssysteme GmbH Robert-Koch-Straße 100 D-85521 Ottobrunn, Germany Telex Pte. Ltd.