Contents 1. Safety Precautions 01 2. Device Diagram 03 3. SPECIALIZATIONS 04 4, Essential Functions 5. Operational Instructions 5.1. Operating Environment .. 5.2. Control Panel Functions 5.3. How to Use the Humidifier 09 5.4. Battery Replacement 10 6. Cleaning and Maintenance n 7.
Failure to follow the instructions exactly as shown may result in fire, electric shock, and/or serious injuries. ‘away from TV, audio equipment and antihero electric appliances. . || @Place the unit away from any heat source, such as a sumac, avoid direct sunlight. ® Place the appliance 2 meters away from TV, audio equipment, and other electric appliances ( Figure D).
@® Make sure the water tank cover is tightly sealed after adding water. You can turn the water tank upside-down to check whether the tank cover is attached securely or not. @® Do not scratch the atomizing plate. @ Do not touch the water or internal elements while the device is operating. @® Do not move the device while it is operating. @ Do not cover the mist nozzles. @ Do not touch the mist when in warm mist mode. @® Do not attempt to repair the device.
Nozzle Water Tank LED Display. Humidity Sensor Power Cable EE ‘Aroma Of Box Dust Screen and Filter Cotton Water Level Sensor Atomizing Plate PTC Heater Note: To guarantee accurate humidity detection, keep the humidifier (especially the humidity sensor) dry before use.
Model HT-2119 Capacity 45L Voltage 100-240V/ 50-60Hz Electric Shock Safeguard Grade I Max. Cool Mist Capacity 300mL/H Max, Warm Mist Capacity 350mL/H Power 40W Space Application (30-50m') « @ This device can humidify a large area quickly and evenly. @ This humidifier can emit both warm and cool mist as needed. @ Thanks to the humidifier’s intelligent humidification technology, the room will remain at a fixed humidity percentage automatically.
5.1. Operating Environment @ Only operate the humidifier in indoor environments between 41-113° F and lower than 80% relative humidity. @ Do not fill the tank with water hotter than 105°F. ® Filling the tank with purified water is recommended. 5.2.
If the device lacks water, it will alert you (see section on Water Shortage Alert). Press the ON/OFF button again to cease operation. The humidifier will enter standby mode automatically. Note: 1. If the humidifier has been turned off but has not been unplugged,the previous settings will be restored automatically. 2. After the humidifier has been turned off, the internal fan will run for 3 minutes to dry the air channel and prevent unwanted growth of bacteria and fungi.
Touch the button once the LED screen will display aa « (default mode). Mist will continuously spray no matter what the ambient humidity is. Touch the button again, the LED screen will display 30% and the Humidity indicator ® lights up. Each subsequent press increases 5% of humidity level until it reaches to 80%. | steep Button Once the Sleep button is pressed, the humidifier will enter sleep mode. Button tones will be silenced and all the indicators are off. All functions still work in the sleep mode.
your desired settings and running time, the LED screen will display the time remaining. Once the set time has expired, the unit will automatically stop and enter standby mode. In order to begin humidifying again, you will need to press the ON/OFF button (if the water shortage protection state is engaged, the unit won't spray mist). Note: Press the Timer button for 2 seconds to turn off the LED display. This will not affect the previous selected settings. Press any button to turn the LED display back on.
5.3. How to Use the Humidifier 1. Liftituptoremovethewatertank / —— ©] (Figure D). 2. Flip the water tank upside down and twist the cap counterclockwise to open the tank (Figure 3. Fill the water tank with cool, clean water (at least 3L) (Figure : 4. Screw the cap onto the water tank tightly and reattach the tank. 5. Plug the power cord into an outlet and press the ON/OFF button to turn it on. For more information on settings, see the “Control Panel Functions” section. 6.
7. For filtration, follow the steps below: a) Lift it up to remove the water tank. b) Twist the cap counterclockwise to open the water tank. <) Mount a filter on the cap and twist the filter clockwise. d) Screw the cap onto the water tank tightly and reattach the tank. e) Restart the device. Fo J = Step 1 Note: a. Replace the filter at least every 3 months. b. Clean the filter surface regularly and rinse the internal components with a strong jet of water. c.
1. Press the locking tab toward the pulling slot to remove the battery compartment (Figure 1). 2. Properly dispose of the old battery according to local regulations. 3. Place a new 3V CR2025 battery into the battery compartment with the positive side facing up (Figure 2). 4. Replace the battery compartment into the remote. Note: The maximum working distance for the remote control is 5 meters (16 fL), Naming: Store maintenance and clearing, be sure fo unplug in the unt.
« Humidifier collection: When the humidifier wil be stored for a Lang period, clean it and dry It, Putin the original box and store tin a dry place . A Precautions when cleaning: m Do not use hard fools to touch the atomizer, only a cotton swab or brush can be used to clean it; m Do not wipe the product with chemical solvents, gasoline, kerosene and polishing powder; m Do not use detergent fo clean It.
Problem Possible Cause Solution There is no mist There is too much water in the tank. 2. Pour out the water and follow the instructions to refill the water. spraying. ore : . ere snot enough water Pour more water into the tank. in the tank, Remove the humidifier from the The machine is brand new. packaging lest chitin wellhead mist has ventilated area for 12 hours. strange smell. The water in the tanks Empty the tank and pour in clean dirty. water, There is not enough water .
the vapor does not have enough time to evaporate. Problem | Possible Cause Solution The humidifier 1s placed . It is recommended to place the ~ directly on the ground or in . The mist wets the humidifier on stable or chairing slow position, therefore N Lo floor. higher position to allow more time to evaporate. There is no warm mist after pressing the heating button. The heating function has not been activated fora sufficient amount of time. Make sure the heating function is on, then check the mist 1.