CMY Zoom 575 User Manual Elation Professional 4295 Charter Street Los Angeles, Ca 90058 www.elationlighting.com Rev.
CMY Zoom 575™ ©Elation Professional® 2 CMY Zoom 575™
CMY Zoom 575™ CONTENTS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… c. 3 Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 4 e. Discharge Lamp Warning……………………………………………………… 4 2. Safety Instructions………………………………………………………........…………. 7 3. Features…………………………………………………………………………………… 9 4. General Guidelines………………………………………………………………………. 10 5.
CMY Zoom 575™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The CMY Zoom 575,™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
CMY Zoom 575™ Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The CMY Zoom 575™ carries a two year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package.
CMY Zoom 575™ Thus, lamp should always be replaced at the end of their recommended duty cycle. Extreme caution should be used when operated this or any fixture fitted with a gas discharge lamp. Never open this fixture while in use! During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture.
CMY Zoom 575™ 2. SAFETY INSTRUCTIONS The CMY Zoom 575™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked.
CMY Zoom 575™ may increase the risk of damage and/or personal injury. 10. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture. 11. Do not attempt to operate this fixture if the power cord has become damaged or frayed. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims.
CMY Zoom 575™ 3.
CMY Zoom 575™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, etc. Do not attempt operation or installation without a proper knowledge on how to so. This fixture was designed for indoor use only, use of this fixture outside will void manufactures warranty. Consistent operational breaks may ensure that the fixture will function properly for many years to come. Do not shake the fixture around.
CMY Zoom 575™ 5. LAMP INSTALLATION INSTRUCTIONS Installing or replacing the lamp Only install the lamp with the device unplugged from the mains. The lamp has to be replaced when it is damaged or deformed. Before replacing the lamp, be sure the unit has had ample time to cool. To avoid self injury, never touch the lamp when it is hot. During the installation of the discharge lamp do not touch the glass portion of the bulb with your bare hands.
CMY Zoom 575™ equivalent). Please remember there is only one way to insert the lamp and the lamp should fit completely in the lamp socket. 5. Once the lamp has been inserted into the socket, gently slide the socket assembly back into place and secure with the two Phillips screws. 6. Always be sure to optimize the lamp after lamp replacement. Do not operate this device with open cover Lamp Optimization The lamp orientation and optimization must be adjusted after every lamp change.
CMY Zoom 575™ adjustment screws ("1, 2, 3”) counterclockwise turn until the light is bright and evenly distributed. Please remember that a MSD 575/2 lamp is not a hot-restrike lamp therefore, you should wait at least 15 minutes before attempting to strike the lamp once it has been turned off.
CMY Zoom 575™ 6. MOUNTING and INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personal. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
CMY Zoom 575™ Mounting points Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. The electric connection must only be carried out by a qualified electrician.
CMY Zoom 575™ Clamp Mounting The CMY Zoom 575™ provides a unique mounting bracket assembly that integrates the hanging yoke as well as the safety cable rigging point in one unit (see the illustration below). When mounting this fixture to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke.
CMY Zoom 575™ 7. Understanding DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below). If you are constructing your own cables be sure to use two conductor shielded digital cable rated at a 120 ohms (this cable can be purchased at almost all professional sound and lighting stores).
CMY Zoom 575™ other side to the male 3-pin XLR input of the moving head (Please refer to the diagram below.). You can chain multiple moving heads together through serial linking. The cable needed should be two conductor, shielded cable with XLR input and output connectors. Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™.
CMY Zoom 575™ Fixture DMX addressing; All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the head of the fixture.
CMY Zoom 575™ signal the display will flash "A.XXX" (XXX representing the actual DMX address). If your fixture is connected to a DMX controller and the display is flashing (not receiving a DMX signal), please check the following: - The 3 PIN XLR plug (cable with DMX signal from controller) is not connected or is not inserted completely into the DMX input jack. - The DMX controller is switched off or defective. - The DMX cable or connector is defective.
CMY Zoom 575™ 8. DISPLAY LED INDICATORS The CMY Zoom 575™ has two LED indicators on the display. These indicators are designed to give a quick visual indication of the fixtures’ status. The illustration below details the functionality of the LED indicators. . . DMX OK . .
CMY Zoom 575™ 9. FIXTURE MENU On-Board System Menu: The CMY ZOOM 575™ comes with an easy to navigate system menu. This next section will detail the functions of each command in the system menu. LED Control Panel: The control panel located on the top, front of the fixture allows you to access the main menu and make all necessary adjustments to the CMY Zoom 575™. During normal operation, tapping the “MODE/ESC” key once will access the fixture’s main menu.
CMY Zoom 575™ COLR Reset only motors for colors Reset only motors for shutter and/or dimmer Reset other motors Displays the total fixture running time Displays a lamps running time SHTR TIME OTHR LIFE LAMP 6 MIC CLMP M-XX M-70 7 DISP 5 VALU D ON FLIP LAAU RDMX 8 SPEC DLOF DLAY SPOT DFSE FANS VER ADJU STEP 9 EDIT SCXX REC.
CMY Zoom 575™ Main Menu Functions 0. ADDRESS MENU - AOO1 - A511 (Value) - This is where you set the fixtures DMX address. Setting/Changing the DMX Address After applying power to the CMY ZOOM 575™ the LED will display the fixture’s current DMX address immediately after the reset sequence. If the fixture is not receiving a DMX signal the display will flash continuously. To set or adjust a DMX address, please follow the procedure below: 1.
CMY Zoom 575™ will test the color channel, changing the color one by one and show the rainbow effect with different speeds. Again please remember, there are 10 DMX channels, and all except channels 3, 6, and 10 can be tested 4. Press MODE/ESC to exit. 2. PLAY MENU RUN – This feature is used to run the internal preset programs in either a Master/Slave or a stand-alone operating mode. Follow the procedure below to enter the run menu: 1. Access the main menu. 2.
CMY Zoom 575™ 4. Tap the UP or DOWN button to select “OFF”, “RUN” or “AUDI” and press ENTER to confirm. 5. Press MODE/ESC to return to the main menu. 3. LAMP MENU – This menu function will manually turn the lamp on and of f. Follow the procedure below to enter the lamp menu: 1. Access the main menu. 2. Tap the UP button until “LAMP” is displayed, press ENTER. 3. The display will show “ON/OFF”. 4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this function. 5.
CMY Zoom 575™ COLR - When you activate this reset function, the fixture will only reset the color wheel motor. 1. Access the main menu. 2. Tap the UP button until “RESE” is displayed, press ENTER. 3. Tap the UP button until “COLR” is displayed, then press ENTER to confirm and begin the reset process. 4. Press MODE/ESC to return to the main menu. GOBO - When you activate this reset function, the fixture will only reset the gobo wheel motor. 1. Access the main menu. 2.
CMY Zoom 575™ 2. Tap the UP button until “RESE” is displayed, press ENTER. 3. Tap the UP button until “OTHR” is displayed, press ENTER to confirm and begin the reset process. 4. Press MODE/ESC to return to the main menu. 5. TIME MENU - LIFE - Displays the fixtures total running time. LAMP - Displays the lamp running time. CLMP - Clears the lamp running time. LIFE - With this function you can display the total running time of the fixture. 1. Access the main menu. 2.
CMY Zoom 575™ 3. Tap the UP button until “CLMP” is displayed, then press ENTER to reset the lamp running time. 4. Press MODE/ESC to return to the main menu. 6. MIC MENU - This function allows for electronic control of the internal microphone’s sound sensitivity. 1. Access the main menu. 2. Tap the UP button until “MIC” is displayed and press ENTER. 3. The display will show “M-XX” (Where XX represents a value between 00 & 99). 4.
CMY Zoom 575™ 2. Tap the UP button until “DISP” is displayed. 3. Press ENTER, the display will show “VALU”. 4. Tap the UP button until ”D-ON” is displayed and tap the ENTER button. 5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. FLIP – This function will reverse the display readout buy 180˚. 1. Access the main menu. 2. Tap the UP button until “DISP” is displayed. 3.
CMY Zoom 575™ feature on and off. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “LAAU” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. RDMX – This function allows the DMX address to remotely be adjusted from a DMX console.
CMY Zoom 575™ 2 to a value of “7” and use channel 3 to set your address to 57 by selecting a channel value of 57. Example 2: If you want to set the starting address to 420, set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420). 4. Wait for approximately 20 seconds for the unit to complete the address reset function. DLOF – This feature allows you to control the lamp via DMX. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3.
CMY Zoom 575™ 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “DFSE” is displayed, press ENTER. 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. DFSE - With this function you can restore the factory settings of the device. All settings will be set back to the default values.
CMY Zoom 575™ 5. Press UP or DOWN button to select “HIGH” or “AUTO”. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. VER - Use this function to display the Software version of the unit. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “VER” is displayed, press ENTER. 4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc. 5. Press ENTER or MODE/ESC to exit.
CMY Zoom 575™ 9. Once you reach your desired calibration press ENTER to confirm and lock in your calibration. 9. EDIT MENU - T his menu item allows you to write a program into the fixture’s memory (EEPROM) via the control panel or via an external DMX controller. STEP (S-01 - S-48) - These are the steps slots that you write your programs into. There are at total of 48 steps. SCXX (SC01 – SC48) - These are the scenes that are stored in your program. There are a total of 48 scenes.
CMY Zoom 575™ STEP - With this function you can program the number of steps in your individual Program. 1. Access the main menu. 2. Tap the UP button until “EDIT” is displayed, press ENTER. 3. Tap the UP button until “STEP” is displayed, press ENTER. 4. The display shows “S-01”, this indicates the first step of your program. You can call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that the scene will “RUN” the first 5 scenes you saved in “Edit.” 5.
CMY Zoom 575™ 5. The display will show the DMX value for the channel that is being edited. It will be displayed as “07XX,” it stands for Channel 7 of the editing scene, the DMX value is “XX.” 6. Adjust the DMX value by tapping the UP button, until you get the expected effect for this channel. 7. Press ENTER to enter the editing of the other channels of the scene. 8. Repeat steps 5-8, until you finish setting all the DMX values for all the channels of this scene, each scene can have 7 channels maximum. 9.
CMY Zoom 575™ the first scene. 9. Adjust the Step-time as described above. 10. Call up the second scene in your controller now. 11. Repeat steps 5-11 until all desired scenes are downloaded. 12. Press MODE/ESC to exit. The number of steps can be defined under “STEP” and the scenes can be called up under “RUN.” RUN - With the function “RUN”, you can run your pre-made program. You can set the number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit. 1. Access the main menu.
CMY Zoom 575™ 10. DMX CHANNEL TRAITS The chart below details the channel layout for 11 DMX channels.
CMY Zoom 575™ DMX channel function and values: Channel 1 - Color Wheel: 0-15 Open / white 16-31 Red 32-47 Blue 48-63 Green 64-79 Light Yellow 80-95 UV filter 96-111 CTB 112-127 CTO 128-189 Forwards rainbow effect from fast to slow 190-191 No rotation 192-255 Backwards rainbow effect from slow to fast Channel 2 - Cyan Color Wheel: 0-255 Cyan (0-white, 255-100% Cyan) Channel 3 - Magenta Color Wheel: 0-255 Magenta (0-white, 255-100% magenta) Channel 4 - Yellow Color Wheel: 0-255 Yellow (0-white, 255-100% Yell
CMY Zoom 575™ Channel 8 - Zoom: 0-255 Zoom 27 - Zoom 19 Channel 9 - Color macros - CMY and color wheel 0-7 Off 8-15 Macro1 16-23 Macro2 24-31 Macro3 32-39 Macro4 40-47 Macro5 48-55 Macro6 56-63 Macro7 64-71 Macro8 72-79 Macro9 80-87 Macro10 88-95 Macro11 96-103 Macro12 104-111 Macro13 112-119 Macro14 120-127 Macro15 128-135 Macro 16 136-143 Macro 17 144-151 Macro 18 152-159 Macro 19 160-167 Macro 20 168-175 Macro 21 176-183 Macro 22 184-191 Macro 23 192-199 Macro 24 200-207 Macro 25 208-215 Macro 26 216-22
CMY Zoom 575™ 246-255 No function Channel 11 – Lamp on/off, reset, internal programms 0-19 Color change normal 20-39 Color change to any position 40-59 Lamp on 60-79 Lamp switch off 80-84 All motor reset 85-87 No function 88-90 Colors motor reset 91-93 No function 94-96 Shutter & Dimmer motor reset 97-99 Other motor reset 100-119 Internal program 1 120-139 Internal program 2 140-159 Internal program 3 160-179 Internal program 4 180-199 Internal program 5 200-219 Internal program 6 220-239 Internal program
CMY Zoom 575™ 11. ERROR CODES: When power is applied, the unit will automatically enter a “reset/test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “02Er,” it means there is some type of error with the channel 2 motor.
CMY Zoom 575™ the reset.
CMY Zoom 575™ 12. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. There must not be any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for UV radiation leakage.
CMY Zoom 575™ 13. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
CMY Zoom 575™ identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
CMY Zoom 575™ 14.
CMY Zoom 575™ 15.
CMY Zoom 575™ 16.
CMY Zoom 575™ 18. TECHNICAL SPECIFICATIONS Power supply: Operating Voltage Power consumption _98VAC, 50Hz;_120VAC, 50Hz;_208VAC, 50Hz; _220VAC, 50Hz;_230VAC, 50Hz;_240VAC, 50Hz; or _98VAC,60Hz;_120VAC,60Hz;_208VAC,60Hz; _220VAC,60Hz;_230VAC,60Hz;_240VAC,60Hz; 120V = 6A/250V, GMA (5x20mm fine-wire fuse) 220V = 3A/250V, GMA (5x20mm fine-wire fuse) 800w nominal Lamp: Type Life time Color temperature Luminous flux MSR 575/2 (Phillips) 1000 Hrs 7200˚ K 49.
CMY Zoom 575™ Elation Professional 4295 Charter Street Los Angeles, CA. 90058 323-582-3322 / 323-582-3108 fax www.ElationLighting.com /Info@ElationLighitng.