Specification Sheet

Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Tankless Electric Water Heater
Series Two
, "TC"
Staged Models (Two Heating Modules) with Thermostatic Control
Applications
Single or multi-xture
Commercial/Industrial
Adjustable temperature setting with +/–1°F temperature stability
Solar backup with FS option
Performance Features
Turns on in stages based on hot water demand
On demand hot water
Continuous hot water. No storage capacity to run out
Reduces installation cost and material. No T&P relief valve
needed (check local codes) or venting
Easy installation with integral 3/4" NPT ttings
Cut energy waste. Flow switch activates heater only on demand
(no standby heat loss)
Two glass-ber reinforced heater bodies and nichrome
elements – a unique, patented ow path ensures optimum heat
transfer and extended element life
Warranty, ve (5) years limited on leaks, one (1) year parts
Field serviceable replaceable cartridge element
Unit mounts on wall
High temperature limit switch
Optional Features
Factory set ambient to 180°F (FS)
Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp
setting (ML)
Sanitation 180°F (S)
N4, N4X (304SS) enclosures
Product Specications
Dimensions: 10.25" x 10.75" x 4.5"
Weight: 10.5 lb
Cover: Enameled steel
Color: White
Element: Dual replacement cartridge inserts
Thermostatic control (+/-1°F) accuracy at steady
state
Fittings:
3/4" NPT ttings at bottom of unit
Min. Dynamic Operating Pressure: 40 PSI
Max. Dynamic Operating Pressure: 150 PSI
UL listed le number: E86887
U.S. Patent #'s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specication
Tankless water heater shall be an Eemax Series Two model
number EX_________________________.
Heater shall have two heating modules. Element shall be
replaceable cartridge insert. Unit shall have a replaceable lter
in the inlet connector. Heater shall be tted with 3/4" NPT water
connections. Maximum operating pressure of 150 PSI. Hot water
storage tanks prohibited. Unit shall be Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Enclosure to be tted with the following features:
_____ FS
Factory set ambient to 180°F
_____ ML Multi lavs 0.3 turn on. Staged up to
4 lavs 110°F temp setting
_____ S
Sanitation 180°F
_____ N4 NEMA 4 steel cabinet with powder coat nish
_____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
In USA
Assembled