AI-2003W & AI-2004W Quick Installation Guide 09-2019 / v1.
Contents I. Safety Information ...............................................3 II. Product Information .............................................4 II-1. Package Content .............................................................................. 4 II-2. LED Indicator ................................................................................... 5 II-3. Hardware Introduction .................................................................... 7 II-4. System Requirement .....................
I. Safety Information For effective sensing and retrieval of environmental data, please install the unit with the safety restrictions outlined below: 1. 2. 3. 4. 5. 6. 7. 8. Must be in locations with good air circulation. Must be positioned for proper air intake to achieve cross ventilation. The air inlet must be kept clear and should be rechecked regularly. Must be in locations close to a power supply and has good Wi-Fi internet signal capable of connecting to the Internet 24 hours a day, 7 days a week.
II. Product Information The AI-2003W (7-in-1) & AI-2004W (8-in-1) Multi-Sensor Indoor Air Quality Detector is your best air quality solution – with visible figures/display that intuitively simplifies data reading to aid the improvement of indoor air quality for homes, schools, healthcare institutes, smart buildings and smart city projects. II-1.
II-2. LED Indicator 1.
2. LED Ring Air quality LED and consolidated air quality LED can be turned on or off. By default, the LED is turned on. To turn on / off the LED, press and hold the center button for 5 seconds. LED Color Consolidated Air Quality & AirBox Status Green Blue Red LED Status Description On Consolidated air quality: Good AirBox in default Consolidated air quality: Unhealthy System Status LED will always be on (flashing or stayed on) when the unit is powered. 3.
II-3. Hardware Introduction 1.
2○ 3 1○ ○ Connector: 1. NO1 and NO2 pin for Air Circulator 2. A+ and B- pin for Signal Board 3. VCC pin (Voice Controlled Carrier) * VCC (5V) controls NO1 and NO2. * Only support 2 ports Air Circulator. Built-in Sensor Sensors Model PM2.5 PM10 CO2 CO TVOC HCHO Humidity Temperature (NDIR) AI-2003W v v v AI-2004W v v v II-4. - v v v v v v v v v System Requirement Internet with Wi-Fi Connection (802.
II-5. Total Air Quality Solution Structure *AI-2003W and AI-2004W only support Wi-Fi connection. *3rd party air circulator support is for specific project only.
III.Installation This section will guide you through the steps to connect your air quality detector to the Internet. III-1. Hardware Installation 1. Please connect the power adapter to the unit (demonstrated on the left) and a power socket. 2. Please wait a moment for the device to boot up. Proceed to the Internet connection procedure when the System Status LED starts flashing in Red.
III-2. Air Circulator Setup via Bluetooth You can connect the air circulator to the EdiGreen Plus via Bluetooth. NOTE: Please make sure to turn on the Bluetooth of your phone. Device Management: Please go to menu and tap “Device Management”. Device management allows users to remotely configure or upgrade firmware enrolled devices such as AirBox or Air Circulator.
There are several options for your Air Circulator, please refer to below picture for more details, 12
III-3. Smart App Installation Search and download "EdiGreen Plus" in Apple App Store or Google Play Store. Launch the "EdiGreen Plus" in your smart mobile device. For Internet connection procedure, please follow the instructions below according to your mobile device Please make sure… ˙ "Access to my location" is turned on. Android OS iOS ˙ Your mobile device is able to connect to your home's Wi-Fi network or whichever network you anticipated the detector to connect to.
Please follow the steps below to set up EdiGreen Plus on your phone: ˙ Before starting the EdiGreen Plus, please contact your distributor or SI, where you purchased the device, to claim the EdiGreen Plus account “Email and Password”. ˙ Go to your mobile device’s Wi-Fi settings, and connect to the Wi-Fi. Please make sure this network has internet connectivity. III-4. Android OS i. Open the EdiGreen Plus, and enter your “Email and password” to log in. ii. Tap “Setup”.
iii. The app will start searching for available device. Tap the desired Wi-Fi network. iv. Enter the Wi-Fi password and tap 15 to continue.
v. Please wait a moment for the setup process. vi. Setup Complete! Now you are able to monitor the air quality near your unit with your mobile device anywhere (as long as you have access to the Internet).
III-5. iOS i. Open the EdiGreen Plus, and enter your “Email and password” to log in. ii. Tap “Setup Device”.
iii. Enter the last two digits of your AirBox. Please find the unique SSID of your detector on the product label. The final 2 digits ** of the SSID "AirBox_Setup_**" is the final two digits of the detector's “Setup WiFi SSID”.
iv. Press Join v. The app will start searching for available Wi-Fi network for the detector. Tap the desired Wi-Fi network and enter the Wi-Fi password and press OK to continue.
vi. Please wait a moment for the setup process. vii. Congratulations! Your AirBox and Edigreen Plus is up and running! Note: The system status LED of AirBox should be turned on in blue.
III-5. Deploying the Unit After connecting to the Internet (and your mobile device's EdiGreen Plus app), you can choose how to place your air quality detector. 1. Rubber Legs The rubber legs (shown below) act as shock prevention and anti-slide support. i. Simply place the unit with the center button facing upwards on a bench or flat surface.
2. Using Device Stand Use the Device Stand to hold the device on a surface. i. Locate the anchors on the Device Stand and the anchor holes on the device. Insert the anchors into the device. ii. Push the anchors towards the smaller ends of the anchor holes to fix the Device Stand.
iii. Place the unit at your desired location in the position shown below: The bottom of the stand has rubber to act as anti-slide support.
IV. Reset to Factory Default Settings If you experience problems with the device, try rebooting it by reconnecting the power. If rebooting does not work, try resetting it back to its factory default settings. This resets all settings back to the default settings. To perform a factory reset, please follow steps below: 1. Press and hold the center button (indicated in the picture below) for at least 10 seconds until System Status LED shows up Red light. After that, you can release it. 2.
V. Cleaning the Unit Choose either of the two options below depending on the cleaning tool you have. If you have other pump-like cleaning tools available (e.g. for computers), you may also utilize them. Please be careful to not exert extremes of force or temperature / humidity onto the sensors to prevent damaging them. It is recommended to clean the sensors every 3-6 months for maximum sensor functionality. V-1.
V-2. Dust-off Canned Compressed Air A general dust-off compressed air will be sufficient. 1. Direct the nozzle of the compressed air at an opening (Figure 3 or Figure 4) of a sensor. 2. Keep the nozzle at 10cm from the sensor opening. 3. Use short bursts (1-2 seconds) of air spray a few times to clean the sensor. 4. Make sure all sensor openings are cleaned.
COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd. Edimax Technology Co., Ltd.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EU Declaration of Conformity English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU, 2014/35/EU. Français: Cet équipement est conforme aux exigences essentielles et autres dispositions de la directive 2014/53/EU, 2014/35/EU. Čeština: Toto zařízení je v souladu se základními požadavky a ostatními příslušnými ustanoveními směrnic 2014/53/EU, 2014/35/EU.
Declaration of Conformity We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the European Radio Equipment Directive . Equipment: Indoor Air Quality Detector Model No.: AI-2003W/AI-2004W The following European standards for essential requirements have been followed: Directives 2014/53/EU Spectrum EMC EMF : EN 300 328 V2.1.1 (2016-11) : EN 301 489-1 V2.1.1 (2017-02) EN 301 489-17 V3.1.
Notice According to GNU General Public License Version 2 This product includes software that is subject to the GNU General Public License version 2. The program is free software and distributed without any warranty of the author. We offer, valid for at least three years, to give you, for a charge no more than the costs of physically performing source distribution, a complete machine-readable copy of the corresponding source code.
intact all the notices that refer to this License and to the absence of any warranty; and give any other recipients of the Program a copy of this License along with the Program. You may charge a fee for the physical act of transferring a copy, and you may at your option offer warranty protection in exchange for a fee. 2.
Therefore, by modifying or distributing the Program (or any work based on the Program), you indicate your acceptance of this License to do so, and all its terms and conditions for copying, distributing or modifying the Program or works based on it. 6. Each time you redistribute the Program (or any work based on the Program), the recipient automatically receives a license from the original licensor to copy, distribute or modify the Program subject to these terms and conditions.