Owner's manual

SAVE THESE INSTRUCTIONS!
M2P-4RD-SL-_
- This product is ETL listed for indoor dry locations.
- This product can be installed to a 4" electrical box with
round plaster ring, or to an octagon electrical box.
- Minimum electrical box volume must be 6 cubic inches
(98 cubic centimeters).
- This product should be installed by a qualified electrician.
1: Turn the power to electrical box off.
2: Connect the top contact wire (black wire) to the low voltage
wire marked "HOT 1" with a wire nut.
3: Connect the middle contact wire (coming out of the
cylindrical connector) to the low voltage marked "HOT 2"
with a wire nut.
4: Connect the remaining side wire to the low voltage wire
marked "COM" with a wire nut.
Installation Instructions for Monorail 2 Circuit Sloped 4" Round
Extended Single Power Feed Canopy
Install the Canopy
904-M2P-4RD-SL-03
IMPORTANT INFORMATION
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
info@edgelighting.com
NOTE: Use the universal round crossbar (provided) if the electrical
box holes are not spaced 2-3/4" apart.
NOTE: The low voltage wires should be present in the electrical
box. Refer to the instructions provided with the remote
transformer to install the transformer and the low voltage wires
before proceeding with the steps below.
2
A
TOP CONTACT
WIRE
CYLINDRICAL
CONNECTOR
MIDDLE
CONTACT WIRE
HOT 2
HOT 1
SIDE WIRE
COM
4
3
5: Place all wires inside the electrical box.
6: Secure the power feed canopy to the electrical box by
tightening the two provided #8-32 screws with the 3/32
Allen wrench.
B
6
3/32 ALLEN
WRENCH
6
#8-32
SCREW
5
© 2011 Edge Lighting. All Rights Reserved.
NOTE: If necessary adjustments can be made to the height of the
power feed rod by following step "Shortening the Power Feed Rod
Height" on page 3.

Summary of content (3 pages)