Certification Exhibit FCC ID: Z9O-FAS1526 IC: 10060A-FAS1526 FCC Rule Part: 15.209, 15.249 IC Radio Standards Specification: RSS-210 ACS Project: 13-2146 Manufacturer: UltraClenz, LLC Model: FAS1526-00 User Manual 3998 FAU Blvd.
Patient Safeguard System Badge Application Directions for Use For Use with FAS1526 (Badge Configuration Pod) and FAS1527 (PSS Badge) Revision 0 UltraClenz, LLC
ProClenz DSP2000 Performance UltraClenz, LLC Table of Contents 1.0 Purpose ................................................................................................................................................................2 2.0 PSS Badge Application Main Screen ...................................................................................................................2 2.1 Menu .............................................................................................................
ProClenz DSP2000 Performance UltraClenz, LLC 1.0 Purpose The function of the PSS (Patient Safeguard System) Badge Application is to allow the hospital staff to quickly and efficiently manage both the settings of the Badge and the data related to the Badge normally accessed through the PSS Dashboard. The application consists of one main screen where most functions are accessible and a number of secondary screens used for specific functions.
ProClenz DSP2000 Performance UltraClenz, LLC used to change the mode that the Pod is in by changing the range of the Pod’s RF transmitter. “Connect to Dashboard” is used to reconnect to the Dashboard if communications are lost for any reason. Under Help there is one selection “About” which gives information about the Application and the Pod. 2.2 Pod Control (see Figure 2) This section consists of four buttons that are used to control the PSS Badge Configuration Pod.
ProClenz DSP2000 Performance UltraClenz, LLC Badge Firmware Revision Badge Address Badge Battery Level Badge Area Figure 3 Badge Control 2.4 Badge Settings (refer to Figure 4) Badge settings are used to change the five most often adjusted settings that control the behavior of the Badge. Audio Volume LED Brightness Grace Periods Set To Factory Default Button Figure 4 Badge Settings Audio Volume consists of three radio buttons used to set the volume of the audio reminders for all states.
ProClenz DSP2000 Performance UltraClenz, LLC 2.5 Dashboard Settings (refer to Figure 5) The Dashboard Settings are used to maintain the information associated with a Badge that is stored on the Dashboard. This information is used to connect a Badge with a specific HCW and to help generate reports that show the compliance of a HCW or department. This section consists of four subsections and two control buttons.
ProClenz DSP2000 Performance UltraClenz, LLC 3.0 How the Application Works At boot-up, the Application looks for the Pod at the last Com-Port (communication port?) in which it was located. If the Pod is not there, the Application scans all the available Com-Ports (communication port?) looking for the Pod. When the Pod is found the Application then tells the Pod to scan for any Badges that may be in range.
ProClenz DSP2000 Performance UltraClenz, LLC In the “File name” field enter the desired file name and click the “Save” button to save the new Badge configuration file. The fourth source is to read the configuration from a previously configured Badge. Before the configuration can be uploaded from a Badge it must be scanned and have its address displayed in the “Badge Control”. Select the desired Badge from the list by clicking on its address. Click the “Read” button in the “Pod Control”.
ProClenz DSP2000 Performance UltraClenz, LLC 4.7 Changing the Dashboard Settings The first step in updating the “Dashboard Settings” is to select the appropriate Badge in the “Badge Control” by clicking on its address. The Application will now display the Badge’s Address in the “Badge Address” field of “Dashboard Settings”, this identifies the Badge that the information is associated with.
ProClenz DSP2000 Performance UltraClenz, LLC RF Exposure: “This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
ProClenz DSP2000 Performance UltraClenz, LLC INDIRECT OR SPECIAL DAMAGES OR LIABILITY, TRANSPORTATION, INSTALLATION OR SUBSTITUTION COSTS, DELAYS, OR FOR ANY OTHER DAMAGES, COSTS, OR EXPENSES INCURRED, IRRESPECTIVE OF HOW THEY OCCUR. THIS WARRANTY SHALL NOT EXTEND TO ANY OTHER PERSON OTHER THAN THE ORIGINAL PUCHASER OF THIS EQUIPMENT OR THE PERSON FOR WHOM IT WAS PURCHASED AS A GIFT. This warranty gives you specific legal rights, and you may also have other rights, which may vary from state to state.