E180-ZG120B User Manual EFR32 2.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual CONTENTS FCC Statement............................................................................................................................................................. 4 1.Overview...................................................................................................................................................................... 5 1.1 Brief introduction..........................................................
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 6.3.2 Steps of creating a touch link network........................................................................................................ 14 6.4 Functional parameter description....................................................................................................................15 6.5 HEX User instruction set.........................................................................................................
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 7.3.1 Unicast test.................................................................................................................................................. 33 7.3.1.1 Unicast between end-device and coordinator in the form of short address......................................33 7.3.1.2 Unicast in long address form between end-device and coordinator................................................. 34 7.3.2 Multicast testing......
Chengdu Ebyte Electronic Technology Co.,Ltd E180-ZG120B User Manual FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 1.Overview 1.1 Brief introduction E180-ZG120B is a small, low-power, high-reliability, 2.4GHz ZIGBEE module based on Silicon Labs EFR32MG1B, which is designed and produced by Chengdu Ebyte. The chip comes with high-performance 32-bit ARM Cortex. -M4 core, integrated internal power amplifier. EFR32 is a wireless microcontroller for smart home, IoT transformation and industrial automation. EFR32 network characteristics belong to ZIGBEE 3.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual this period, ZigBee 3.0-compliant devices can join the network. After this period of time, the network will be shut down and no devices can join. It can also be configured to open permanently. Any ZigBee 3.0 standard device can be added; GPIO control:Local/remote GPIO control function,there are 4 IO for users to select. PWM control :Local/remote PWM control function,there are 5 PWM channels for users to select.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 1.3.3 Router The other nodes are allowed to connect with the routing device to extend the coverage of the network. The main task is to forward packets, play the role of relay routing, and have all the functions of the end-device. If one node has multiple paths to another node, when one of the paths fails, the network automatically adjusts to other optimal paths for transmission to ensure data arrives.
Chengdu Ebyte Electronic Technology Co.,Ltd. Operating voltage(V) E180-ZG120B User Manual Min. Typ. Max. 1.9 3.3 3.8 Communication level(V) 3.3 ≥3.3 V ensures output power For 5V TTL, it may be at risk of burning down Working temperature(℃) -40 - +85 Industrial design Frequency(MHz) 2405 - 2480 Support ISM band Power TX current(mA) 135 consumpt RX current(mA) 10 ion Sleep current(μA) 2.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 3. Mechanical characteristics Pin No. Pin item 1 ANT 2 GND 3 PD13 Pin Application direction Input /Output Externally connected with stamp hole Ground, connecting to power source referential ground Input TOUCHLINK pin to be continuously pulled lower than 3000ms and it will initiate a ZLL network or join request The WAKE pin is mainly used to wake up the sleeping terminal. It is high level 4 PD14 Input when power is on.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 1000ms, the serial port parameters of the module will be restored to the default 115200. The ACK pin is used to indicate the last user data transmission status. This pin 11 PB13 Output is pulled low before the transmission is started, and the pin is pulled high after the transmission is successful.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 4.2 Configuration mode When the module enters the configuration mode, the data received by the serial port defaults to the configuration instruction, which configures and operates the function of the device. In the configuration mode, the data received by the serial port is regarded as the hex instruction. 4.3 Mode switch 4.3.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 5.1.2 Multicast mode In multicast mode, first set the group number (for grouping) for the devices in network. The sending device must specify the target group number (to which group to send the data). Then the sending device will send the data received by the serial port to the network, and the devices with the same group number in network will receive the data. 5.1.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 5.2.5 Data+short address+RSSI When the output mode is data + short address + RSSI, after receiving the wireless data, the serial port will output the original data + the short address of the sending device + the RSSI value of the received data packet; 5.2.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual request. ZLL's touch link protocol includes an initiator and a target. The initiator is End-device and Sleep-End-device. The target is generally a router. When the touch link pin is continuously pulled down for more than 3000ms, the initiator will send a network establishment or joining request to the target. 6.1.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual devices with signal strength greater than -40dBm will be scanned), if scanning more than two target devices will affect the success rate of touch link (3) Secondly, after the initiator scans the target device, if it initiates the touch link for the first time, it initiates a request to create a new network to the target; if the touch link has succeeded before, it initiates the touch link to the target. Network request.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual the corresponding mode function introduction; The data output mode is: Transparent transmission; Output mode Read/Write 0、1、2、3、 4、5 Data + short address; Data + long address; Data + RSSI; Data + short address + RSSI; Data + long address + RSSI; It is used to determine whether the data received by the air in the Remote configuration Read/Write 2 byte ID air is a remote configuration command.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 6.5 HEX User instruction set 6.5.
Chengdu Ebyte Electronic Technology Co.,Ltd. 6.5.
Chengdu Ebyte Electronic Technology Co.,Ltd.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual external MCU serial port in wireless receiving state Read UART wake up 36 keep time Read port info.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual node loses the parent node.
Chengdu Ebyte Electronic Technology Co.,Ltd. Start Touchlink E180-ZG120B User Manual Send:F5 01 40 04 FF Send:F5 01 40 04 FF Return:FC 40 00 Return:FC 40 00 6.6 HEX Parameter description 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 0x00 no network 0x01 Currently joining the network 0x02 joined the network 0x03 A network exists, but the parent node is lost 0x04 Leaving the current network 6.6.5 Network PAN_ID pan_id: 0x0000~0xFFFE fixed network PAN_ID 0xFFFF stochastic network PAN_ID PANID Parameters need to be configured before setting up or joining the network. 6.6.6 Network short address: Short_Addr:2 Byte Address randomly assigned by coordinator 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 01 4800 08 76800 02 9600 09 115200(default) 03 14400 0A 128000 04 19200 0B 230400 To change the baud 05 38400 0C 256000 of 06 50000 0D 460800 07 57600 serial you need to restart changed baud rate rate configuration communication, the device, and the will take effect. 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 02 PC6 Port 03 PC7 Port In/Out: Channel output / input mode 0 Output 1 Input level: Channel Level state 0 Low level 1 High level 2 Flip Note: When configured as input, the level indicates the input level value is 0 (low level) or 1 (high level). When the output is configured, the level indicates 0 (low level), 1 (high level), 2 (Level flip) output. 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual adcid:ADC channel ID Channel ID ADC GPIO Port VDD Power supply voltage 0x00 detection 0x01 PC8 Port 0x02 PC9 Port 0x03 PC10 Port 0x04 PC11 Port Voltage: Read ADC channel voltage value( mV) Detectable range 0x0000~0x0E74 (0~3700) voltage 1 Indicates high 8 digits voltage 2 Indicates lower 8 bits If Read value:voltage =0x0C voltage =0xE4 Then voltage:voltage =0x0CE4 Note: If the power supply voltage is the highest 3.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual node from 0 to child_count-1. Such as: Receive:FE 0E 33 FF Retuen:FB 33 0 03 34 F3 0B 03 21 FE FF 57 B4 14 50ms FB 33 1 04 F2 7B 02 1F 21 FE FF 57 B4 14 2 04 A0 82 27 6E 21 FE FF 57 B4 14 FB 33 3 03 F4 3E F3 7C 21 FE FF 57 B4 14 50ms . . . . . . . . . . . . 50ms FB 33 50ms FB 33 index dev_type Short_Addr Mac_Addr 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual Take effect once restart Note: Only the connected device holding the same link key (LinkKey) as the trust center (coordinator) can it connect to the network of the trust center (coordinator), and the trust center (coordinator) transmits the network key to the connected device , The connected device completes the process of joining the network to obtain the network key for normal communication. 6.6.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (3) Modify node type as coordinator, and click the Enter button, the message box prompts "Configure device type success". The general ZigBee 3.0 network is established by the coordinator node, so the factory default end-device node type needs to be changed to the coordinator before establishing the network.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (5)The node type is modified, and the module needs to be restarted to take effect. Click “Module Restart”, and the message box prompts “Module restart successful”. (6)After the module restarts, the transfer mode is entered by default. At this time, click “Enter Configuration Mode” again, the message box prompts “Enter the configuration status successfully, read parameters successfully”.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual ( 7 ) Select the fixed-point networking interface, display the network status as "joined network". The coordinator network is successfully created. 7.2 Quickly join a ZigBee network (1)Open software “E180-ZG120B-Setting”,choose port number, and set the serial port baud rate, open the serial port.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (3) Modify the node type as sleep-end-device, click the Enter button, the message box prompts "Configure device type is successful", modify the network parameters, its PAN ID and transmit channel parameters must be the same as the network to be joined, click "Write network parameters", The message box prompts "Write parameters successfully.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual Similarly, the routing node and the end-device node also join the ZigBee network according to the appeal method. If the node type does not need to be added to another ZigBee network, the Enter button next to the node type configuration also needs to be clicked. Write the parameters after modifying the network parameters, and finally restart to join the new ZigBee network 7.3 ZigBee Network communication test 7.3.1 Unicast test 7.3.1.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (2 )After the target address between nodes is configured, click "enter transmission mode", and the message box will prompt "enter transmission mode successfully". Before communication, confirm whether the module is in transmission mode, and only in the transmission mode can the communication be realized. Input the data to be sent in the sending area, click send, and the received data can be seen in the end-device node message box.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (2)After the target MAC address is configured, the transmission mode needs to be configured. Change the "network address (short address)" to "MAC address", and then write the parameters again. At this time, the target address is configured to unicast in the form of MAC address. (3)After completing the above parameter configuration, click to enter the transmission mode, communicate in the transmission mode.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 7.3.2 Multicast testing ( 1 ) For example, if the end-device device is the receiving end, click "enter configuration mode", modify the network group number to "5", and then write the parameters. The message box will prompt "write parameters successfully". At this time, group ID 5 is assigned to the end-device.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (4)The end-device receiver enters the configuration mode, changes the network group number to "4", and writes the parameter. At this time, because the network group number is not "5", the coordinator multicast data cannot be received. 7.3.3 Broadcast test ( 1 ) For example, when the coordinator broadcasts, click "enter configuration mode", enter fixed-point networking, select broadcast mode, and then write parameters.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual (2)Enter the transmission mode, the message box will prompt "enter the transmission mode successfully", and then broadcast data communication, at this time, all nodes in the network will receive data, including the sending node Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 8. Secondary development design reference 8.1 Mechanical dimensions and pin definitions Pin No.
Chengdu Ebyte Electronic Technology Co.,Ltd.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 8.2 Schematic design 8.3 Development No Keyword Note The module is SOC module with GPIO port. J-link Downloader is used for programming download. We provide demo program for users' reference. Users can download our compiled hex files directly, or change and implement their own functions based on the original code.
Chengdu Ebyte Electronic Technology Co.,Ltd.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual 9.FAQ 9.1 Communication range is too short The communication distance will be affected when obstacle exists. Data lose rate will be affected by temperature, humidity and co-channel interference. The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground. Sea water has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.
Chengdu Ebyte Electronic Technology Co.,Ltd. E180-ZG120B User Manual About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Tel:+86-28-61399028 Fax:028-64146160 Address: BuildingB5,MouldIndustrialPark,199#XiquAve,WestHigh-techZone,Chengdu,611731,Sichuan,China Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
Integration instructions for host product manufacturers according to KDB 996369 D03 OEM Manual v01 2.2 List of applicable FCC rules CFR 47 FCC PART 15 SUBPART C has been investigated. It is applicable to the modular transmitter 2.3 Specific operational use conditions Thismoduleisstand-alonemodular.