Drawing : - TPC252 Issue :-6 Date : - 10/12/13 CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 CD425 PACKAGE CONTENTS Item Description Quantity 1018110 Dehumidifier 1 3086119 Jubilee clip 2 3014315 Reinforced tubing – 16mm I/D 2 X 3M TPC252 Manual 1 Page 2 of 16
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 Page 3 of 16
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 UNPACKING Carefully remove the CD425 dehumidifier unit from its packing and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, as it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The Ebac CD425 dehumidifier removes moisture from the air that circulates through it.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 SPECIFICATIONS MODEL: CD425 HEIGHT: 1193 mm (47”) WIDTH: 1092 mm (43”) DEPTH: 482 mm (19”) WEIGHT: 160 kg (353 lbs) AIRFLOW: 1750 CFM (2975M3/Hr) TOTAL POWER: 3680 (MAX) MAXIMUM OPERATING TEMPERATURE: 35ºC (95ºF) POWER SUPPLY: 220V 3PH 60Hz REFRIGERANT: R407c CHARGE: 2.5Kg "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 OPERATION The CD425 is a self contained low temperature dehumidifier. All electrical contactors, overloads, etc are housed in an electrical box built inside the unit. The unit is equipped with a defrost valve which energized automatically to clear any ice formation on the evaporator coils. This allows the unit to operate at much lower temperatures; the control panel gives indication of the set humidity, drying and defrost status.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 SYSTEM INSALLATION POSITIONING Position the CD425 in the area leaving enough room either end of the unit to allow for easy servicing. Using a spirit level ensure the level in both direction. Failure to do so may result in the drain tray overflowing and flooding of the chamber. WIRING Connect a suitably fused 3 phase mains power supply to the MAINS T/B terminal block inside the electrical box located at the control panel end of the machine.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, 4, AND 5. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Check the power from the power supply panel 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center Unit inoperative 1. No power to unit Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 CD425 SPARE PARTS LIST DESCRIPTION PART NUMBER QUANTITY Compressor 3022168 1 Condenser Coil 3020725 1 Evaporator Coil 3020733 3 Defrost valve 3020803 1 Reversible Filter Dryer 3020930 1 Capillary Tube 3014251 R407c Freon Refrigerant 3100451 2.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 Humidistat Control 2017707 1 Contactor 037H0021 3030355 1 Contactor 037H0041 3030362 1 Relay 3030270 1 Overload 3032646 1 Transformer 3031129 1 Defrost Timer 1619400 1 Knob Spare parts available online ww.EIPLDIRECT.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 Page 14 of 16
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 Page 15 of 16
Drawing : - TPC252 Issue :-6 Date : - 10/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.