Code Specs

Table Of Contents
V5-T1-38 Volume 5—Motor Control and Protection CA08100006E—April 2016 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
IEC Contactors and Starters
XT
IEC Power Control
Catalog Number Selection
XT IEC Contactors and Starters
XTAE, XTAS and XTAR Starters Only—
Maximum Overload Relay
XTOB Maximum Overload Rating
Frame B
P16 = 0.1–0.16A
P24 = 0.16–0.24A
P40 = 0.24–0.4A
P60 = 0.4–0.6A
001 = 0.6–1A
1P6 = 1.0–1.6A
2P4 = 1.6–2.4A
004 = 2.4–4A
006 =46A
010 =610A
012 =912A
016 = 12–16A
Frame C
P16 = 0.1–0.16A
P24 = 0.16–0.24A
P40 = 0.24–0.4A
P60 = 0.4–0.6A
001 = 0.6–1A
1P6 = 1.0–1.6A
2P4 = 1.6–2.4A
004 = 2.4–4A
006 =46A
010 =610A
016 = 10–16A
024 = 16–24A
032 = 24–32A
Frame D
010 =610A
016 = 10–16A
024 = 16–24A
040 = 24–40A
057 = 40–57A
065 = 50–65A
075 = 65–75A
Frame F
035 = 25–35A
050 = 35–50A
070 = 50–70A
100 = 70–100A
Frame G
035 = 25–35A
050 = 35–50A
070 = 50–70A
100 = 70–100A
125 = 95–125A
150 = 120–150A
175 = 145–175A
Frame L
070 = 50–70A
100 = 70–100A
125 = 95–125A
160 = 120–160A
220 = 160–220A
250 = 200–250A
Type
CE = Three-pole FVNR IEC contactor
CS = Three-pole FVNR S Series IEC contactor
CF = Four-pole FVNR IEC contactor
CR = Three-pole FVR IEC contactor
CC = IEC capacitor contactor
AE = FVNR IEC starter
AS = FVNR S-Series IEC starter
AR = FVR IEC starter
Designation
XT = XT line of IEC control
Terminations
Blank = Screw terminals
(6–65A);
5 mm (80–150A);
no lugs
(185–2000A)
C = Spring cage
terminals consult
local sales office
for availability
XTOE Maximum Overload Rating
Standard
Type Suffix
Ground Fault
Type Suffix
Frame B
0.33–1.65A
1–5A
4–20A
Frame C
0.33–1.65A
1–5A
4–20A
9–45A
Frame D
9–45A
20–100A
Frame F, G
20–100A
Frame G, H
35–175A
5E1P6
5E005
5E020
5E1P6
5E005
5E020
5E045
5E045
5E100
5E100
5E175
5G1P6
5G005
5G020
5G1P6
5G005
5G020
5G045
5G045
5G100
5G100
5G175
Frame Size Designation
B = 45 mm
C = 45 mm
D = 55 mm
F = 90 mm
G = 90 mm
H = 140 mm
L = 140 mm
M = 160 mm
N = 250 mm
P = 260 mm
R = 515 mm
Built-In Auxiliary Contact
01 =1NC
10 =1NO
00 = 0NO–0NC
S1 = 1NO–1NC
side-mount auxiliary
11 = 1NO–1NC
top-mount auxiliary
22 = 2NO–2NC
Current Ratings, AC-3
007 = 7A
009 = 9A
012 = 12A
015 = 15A
018 = 18A
025 = 25A
032 = 32A
040 = 40A
050 = 50A
065 = 65A
072 = 72A
080 = 80A
095 = 95A
115= 115A
150 = 150A
170 = 170A
185 = 185A
225 = 225A
250 = 250A
300 = 300A
400 = 400A
500 = 500A
570 = 570A
580 = 580A
650 = 650A
750 = 750A
820 = 820A
C10 = 1000A
C14 = 1400A, AC-1
C16 = 1600A, AC-3
C20 = 2000A, AC-1
XT CE C 007 B 01 AD P16
Coil Codes
See Page
V5-T1-53.

Summary of content (2 pages)