Datasheet

03/23/2012 HPL-ED2011 V2.0 EN (UX111) 1 / 2
Undervoltage�release
Part�no. U-PKZ0(230V50HZ)
Article�no. 073135
Program
Contact sequence
Connection technique Screw terminals
Actuating voltage 230 V 50 Hz
For use with PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
Notes
Can be fitted to the left of:
Motor‐protective circuit‐breakers
Cannot be combined with:
A‐PKZ0 shunt release
When combined with circuit‐breaker, can be used as emergency‐stop device to IEC/EN 60204.
Approbationen
UL approval Yes
CSA approval Yes
Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking
UL File No. E36332
UL CCN NLRV
CSA File No. 12528
CSA Class No. 3211-05
NA Certification UL listed, CSA certified
Specially designed for NA No
General
Terminal capacities
mm
2
Solid or flexible conductor with ferrule
mm
2
1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Solid or stranded AWG 1 x (18 - 14)
2 x (18 - 14)
Main�conducting�paths
Rated operating voltage U
e
V
AC
42 - 480
Rated operating voltage U
e
V
DC
24 - 250
Pick-up-/drop-out�voltage
Pick-up voltage x U
s
0.85 - 1.1
Drop-out voltage x U
s
V 0.7 - 0.35