Cut Sheet

Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T7-19
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.
7.5
Current and Voltage Sensors
CurrentWatch ECSTD Series
ECSTD Series CurrentWatch Current Switches
Contents
Description Page
ECSTD Series CurrentWatch Current Switches
Standards and Certifications . . . . . . . . . . . . . . V8-T7-20
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T7-20
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-21
Technical Data and Specifications . . . . . . . . . . V8-T7-21
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-22
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-22
ECSTD Series CurrentWatch Current Switches
Product Description
The CurrentWatch ECSTD
Series from Eaton’s Electrical
Sector is a family of high
performance current-
operated switches with field-
adjustable time delay to help
minimize
nuisance trips
during start-up and operation.
Designed for motor status
applications where setpoint
accuracy
and repeatability are
critical, the ECSTD Series
offers a linear setpoint
characteristic and constant
hysteresis.
Standard features
include self-powering,
jumper-selectable ranges and
a choice of outputs and
housing styles.
For typical applications of the
Current
Watch ECSTD Series,
see listing on this page.
Application Description
Typical Applications
Motor Protection
Serves as an electronic
proof-of-operation; detects
current draw changes in
motors when they
encounter problems such
as pumps running dry or
pending bearing failure;
non-intrusive and less
expensive to install than
differential pressure flow
sensors or thermal
switches; much quicker
response time than Class
10 overload relays
High Inrush or
Temporary Overload
Current—Adjustable start-
up/delay timer allows 0–15
second delay to eliminate
nuisance trips from high
inrush or short overload
conditions
For the most current information
on this product, visit our Web site:
www.eaton.com
Example Application—
Isolated Alarm System Interfacing
Features
Adjustable Start-Up/
Delay Timer—Field
adjustable from 0–15
seconds to eliminate
nuisance alarms due to
start-up inrush or
temporary overcurrent
conditions
Choice of NO/NC AC or
Universal Outputs
Contact ratings of 1.0A at
240 Vac or universal
outputs of 0.15A at 240
Vac/dc (NO models) and
0.2A at 135 Vac/dc (NC
models) for use with most
standard motor control
systems
Improved Ease of
Installation and Use
Self-powered, split-core
models simplify
installation, 1.0A AC rating
eliminates need for time
delay relay, and status LED
provides visual indication
of setpoint trip and contact
action
Industrial Grade
Performance—Constant
hysteresis and linear
response characteristics
enhance setpoint accuracy
Agency Approved—UL
Listed, CE pending
ECSTD Series Current Switch
Existing
Alarm
System
Audible
Alarm
New
Alarm
System