Switching Devices
Safety Switches
Elevator Control Switch
Contents
Description Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-3
General Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-26
Heavy-Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-31
Six-Pole Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-43
Double-Throw Switches . . . . . . . . . . . . . . . . . . . . . . . V2-T1-45
EnviroLine—Stainless Steel Switch. . . . . . . . . . . . . . . V2-T1-53
EnviroLine—Upper and Lower Window Switches. . . . V2-T1-56
EnviroLine—Receptacle Switches. . . . . . . . . . . . . . . . V2-T1-59
EnviroLine—Non-Metallic KRYDON Switch . . . . . . . . V2-T1-61
Shunt Trip Safety SwitchShunt Trip Safety Switch. . . . V2-T1-63
NEMA 7/9—Hazardous Location Disconnect Switch . V2-T1-66
Quick Connect Switches . . . . . . . . . . . . . . . . . . . . . . . V2-T1-68
Solar Disconnect Switch . . . . . . . . . . . . . . . . . . . . . . . V2-T1-70
316-Grade Stainless Steel Safety Switches. . . . . . . . . V2-T1-72
Mill-Duty Rated, Heavy-Duty, Fusible, Non-Fusible,
Single-Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V2-T1-76
Heavy-Duty Fusible Safety Switches Accepting
Cube Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V2-T1-78
Elevator Control Switch
Catalog Number Selection . . . . . . . . . . . . . . . . . . .
V2-T1-82
Technical Data and Specifications . . . . . . . . . . . . . V2-T1-82
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-82
Auxiliary Power Heavy-Duty Safety Switch . . . . . . . . . V2-T1-83
Left-Handed Safety Switch . . . . . . . . . . . . . . . . . . . . . V2-T1-86
200% Neutral Safety Switches . . . . . . . . . . . . . . . . . . V2-T1-87
Pringle Bolted Pressure Switch . . . . . . . . . . . . . . . . . . V2-T1-88
Type DS, Fusible and Non-Fusible . . . . . . . . . . . . . . . . V2-T1-91
Type Visi-Flex DE-ION . . . . . . . . . . . . . . . . . . . . . . . . . V2-T1-94
Flange Mounted—Variable Depth . . . . . . . . . . . . . . . . V2-T1-98
Flange Mounted—Fixed Depth . . . . . . . . . . . . . . . . . . V2-T1-102
Elevator Control Switch
Features, Benefits and Functions
Standard Features
30–400A, 600 Vac three-
phase fused power switch
200,000A rms short-circuit
current rating
Shunt trip 120V
Control power
terminal block
Ground lug per NEC
Class J Fuse mounting only
(Class J Fuses
not included)
Key to test switch 120V
Mechanically interlocked
auxiliary contact for
hydraulic elevators with
automatic recall (5A,
120 Vac rated) 1NO, 1NC
Optional Features
Control power transformer
with fuses and blocks
Fire safety interface relay
Pilot light—ON
Isolated neutral lug
(oversized 200% rated
neutral option available
where required by
excessive nonlinear loads)
Fire alarm voltage
monitoring relay (to
monitor shunt trip voltage)
NEMA 3R, 4 and 12
enclosures available
through 200A
Phase failure and
undervoltage relay
available, consult factory
For added protection,
use Eaton fuse covers
to improve maintenance
personnel protection,
through 200A (OSHA
1910.333, Paragraph C)
Standards and Certifications
UL 98 Enclosed and
Deadfront Switch
Guide 96NK3917,
File No. E182262
NEMA 1, UL 50,
listed enclosure
cUL
®
per Canadian
Standards C22.2,
No. 0-M91-CAN/CSA
®
C22.2, No. 4-M89