Cut Sheet

V13-T1-42 Volume 13—Counters, Timers and Tachometers CA08100015E—December 2015 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l i z e r s
1/32 DIN LCD Totalizers, continued
Dimensions
Approximate Dimensions in Inches (mm)
1/32 DIN LCD Totalizers
Description Specification
Counting inputs:
Counting input of the DC version Max. 30 Vdc
Slow counting input Max. 30 Hz (NPN)
Fast counting input Max. 12 kHz (PNP)
Switching level NPN: Low 0–0.7V, High 3–30 Vdc
PNP: Low 0–0.7V, High 3–30 Vdc
Counting Input of the high voltage versions 10–260 Vac/Vdc
Counting input Optocoupler input, max. 30 Hz
Min. pulse time 16 ms
Switching level Low: 0–2 Vac/Vdc
High: 10–260 Vac/Vdc
Counting direction switching (only DC versions) Contact input, open collector NPN (switching at 0 Vdc)
Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc
Reset input (only DC and high voltage)—
Minimum pulse time DC: 50 ms; high voltage: 16 ms
Contact input NPN Low: 0–0.7V
High: 3–30 Vdc
High voltage input 10–260 Vac/Vdc
Electrical reset key locking (for DC and AC) Contact input, open collector NPN (switching at 0V)
Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc
1.77
+ 0.024
(45
+ 0.6
)
1.77
+ 0.012
(22.2
+0.3
)
1.89 (48)
MAX. 1.89 (19.3)
0.11 (2.8)
0.12 (3)
1.88 (47.7)
0.87 x 1.77
(22 x 45)
0.94
(24)