Data Sheet

DATASHEET - NZM2-XS-L
Main switch assembly kit, left, frame size 2
Part no. NZM2-XS-L
Catalog No. 266642
Similar to illustration
Delivery program
Equipment supplied Door coupling rotary handle
NZM...-XV4 extension shaft
External warning plate/marking plate in German/English
Black and yellow lightning symbol
Product range Accessories
Accessories Main switch assembly kit for side panel mounting
Standard/Approval UL/CSA, IEC
Construction size NZM2
Description Kit for use as a main switch
Function Actuation of the switch on the control panel side wall
Switch mounting on mounting plate
Standard, black/grey
Protection class IP66
UL/CSA Type 4X, Type 12
Door interlock Lockable in the 0 position using up to 3 padlocks on the handle
can also be modified in I position
Project planning information External warning plate/designation label can be clipped on.
For enhanced busbar tag shroud on the incomer side, please order IP2X protection
against contact with a finger.
Actuation Actuation on the left
For use with NZM2(-4)
PN2(-4), N(S)2(-4)
Design verification as per IEC/EN 61439
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat
and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will
provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be
observed.