EasyIO FW Series – User Reference v3.0 Document Change Log 16th May 2017 Document created. 3rd Oct 2017 Updated AO min load impedance to 10,000 ohms. 11th Jan 2018 Updated Login details IP address. 20th Jan 2018 Updated AO specification and include a warning. 25th May 2018 Updated jumper settings images. th 17 Dec 2018 Updated disclaimer and support channel emails addresses Updated Utility Menu selection explanation. 23rd Jan 2019 Updated wiring diagram.
EasyIO FW Series – User Reference v3.0 Disclaimer Confidentiality Notice The information contained in this document is confidential information of EasyIO Holdings Pte Ltd. Such information and the software described herein, is furnished under a license agreement and may be used only in accordance with that agreement.
EasyIO FW Series – User Reference v3.0 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
EasyIO FW Series – User Reference v3.0 Table of Contents Introduction ....................................................................................................................................................6 Hardware Configurations ................................................................................................................................7 Power supply Connection .................................................................................................................
EasyIO FW Series – User Reference v3.0 Introduction EasyIO FW Series is the most powerful wireless Sedona controller in the market. It is equipped with two 32-bit Processors, the first in the Automation industry, with a 580MHz MTK processor and an ARM M0 Cortex for the I/O management and A-D processing, and also with a Linux 3.18 OS for premium performance. Supports BACnet as server and TCom or premium performance with Niagara AX and N4. The Build in boot loader can be carried out remotely.
EasyIO FW Series – User Reference v3.0 Hardware Configurations Power supply Connection Both AC and DC can be used for EasyIO FW Series controller. Refer to electrical specification for the working range. In order to avoid damage on the controller input/output devices and RS485 connection, use individual power supply for each controller. If a single power supply is used to power up multiple EasyIO FW series, make sure controller power supplies are connected with the same polarity.
EasyIO FW Series – User Reference v3.0 Input Output configuration FW Series range of products comes in few options. Options are referring to IO (Input/Output) configurations.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.0 Wiring diagram Below diagram shows the general wiring diagram for FW series according to its model.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.
EasyIO FW Series – User Reference v3.0 Digital Output Wiring Connection EasyIO FW Series digital output is for general purpose isolated digital output connections (relay output). Pilot Duty rating is as below (Pilot Duty); 24 VAC , 2.0A 24 VDC , 2.0A Digital Output Type 2 Channels – FW-14 only Relay Contacts, SPST NO, 48VA at 24VAC, It does not output voltage or current. It is a dry relay contact.
EasyIO FW Series – User Reference v3.0 Analog Output Connection EasyIO FW series has Analog Output connections. Each Analog Output can only drive voltage. The operating range for voltage mode is 0 – 10V. **We DO NOT recommend you to drive a relay directly from UO 0-10V mode as it is not design for it and will damaged the UO. ** Universal Output Type 4 Channels Voltage: 0 – 10VDC , Min Impedance 2,000 Ohm.
EasyIO FW Series – User Reference v3.0 Universal Input Connection EasyIO FW series has non-isolated universal inputs. The universal input supports three type of analog signal i.e. resistance and voltage via hardware jumper and internal register settings: Universal Input Voltage Resistance Thermistor UI as Digital Input 8 Channels 0 - 10V DC (+/-0.05V) 500 - 500K (+/-10 Ohm) 10K, 20K, 1K Balco, 1K Platinum : All (+/-0.
EasyIO FW Series – User Reference v3.0 Differential Pressure Sensor (FW-08V) **Applicable to FW-08V only** EasyIO FW-8V has an on board differential pressure sensor or some called it Air Flow sensor. The sensor is pre-calibrated by manufacturer and it gives digital signal instead of analog signal. The sensor calibration is calibrated with temperature compensation which gives excellent accuracy. The specifications of the sensor is as below.
EasyIO FW Series – User Reference v3.0 Network and Wireless EasyIO FW series comes with on board wireless connection and 2 ethernet ports. The wireless network comply to IEEE 802.11 standards. It supports IEEE 802.11 B/G/N standard. Each unit is supplied with two (2) 2dBi RP-SMA female jack antenna. Antenna supplied are Omni Direction antenna where it emits its radio signal equally in all direction in a single plane. Make sure both antennas are used for best performance.
EasyIO FW Series – User Reference v3.0 FW Series Wi-Fi Access Point name is preset at factory. Each unit has 2 Wi-Fi Access Point as below. SSID 1 : FW-xxxx , where xxxx is the last 4 digit of the MAC address 01. SSID 2 : Conf-xxxx , where xxx is the last 4 digit of the MAC address 01 (Hidden by default) Mac Address label located at the bottom casing top right hand corner of each FW series controller. The MAC address label is available on the circuit board as well , above the ethernet ports.
EasyIO FW Series – User Reference v3.0 Both SSID (SSID 1 and SSID 2) and ethernet ports has a DHCP server built in. If you are connected to the FW series controller via Wi-Fi or Ethernet you will obtain an IP address assign by the DHCP server. The 2 ethernet ports on board function as a normal unmanaged network switch. It supports 10/100 Mbps Half Duplex and Full Duplex. For details explanation and configurations, please refer to EasyIO FW Network Configuration Guide.
EasyIO FW Series – User Reference v3.0 Login Details EasyIO FW Series default IP address and login details are as below. Primary Network (Main Wi-Fi SSID and Ethernet) Default IP address : 192.168.10.30 Default Subnet : 255.255.255.0 Default Gateway : 192.168.10.1 Secondary Network (Conf Wi-Fi SSID) By this SSID is hidden. This SSID is mainly use for configuration purpose. Default IP address : 192.168.14.1 Default Subnet : 255.255.255.
EasyIO FW Series – User Reference v3.0 Step 6 At the dashboard screen, click expand icon, Then select Utility menu, at the bottom left to view the sidebar. . Utility menu consist of several configuration for the FW series controller. The menu are as below. 1. 2. 3. 4. 5. 6.
EasyIO FW Series – User Reference v3.0 Date Time Configuration This menu is used to perform date and time configuration for the FW controller. The FW Series controller supports Network Time Protocol (NTP) synchronization. To change the Date and Time of the controller, go to the DateTime tab. Click at calendar icon, and change the date or time or both. Click save once is complete. To enable NTP time sync, go to the NTP tab. Check the “enable Network Time Sync". Change the “Time Server” if require.
EasyIO FW Series – User Reference v3.0 Logo Config This menu is used to modified the FW Series login screen logo. The default logo is CPT Tools logo. You can modified the logo to used own custom logo to represent your own organization. Click into the Logo Config Option. Upload a logo to the controller by drag and drop into the doted box or simply click within the doted box.
EasyIO FW Series – User Reference v3.0 Buttons and Indications The controller will do a hardware reset when the Reset Button is pressed whenever manual restart is required. The Service button is used to activate the built-in boot loader program for software upgrade. Each digital output has a correspondence LED to indicate its current state. Image shows the Reset button, Service button and also TXRX indicators. Image shown is an EasyIO FW-14 unit.
EasyIO FW Series – User Reference v3.0 Button and LED indications. Image shown is an EasyIO FW-14. LED Conditions Description Pattern: continuously blinking. ERR is to indicate whenever there is Communication errors between FM-02 module and base board. 1 ERR 2 STS 3 TX/RX Pattern: constantly light up. The controller is undergoing firmware upgrading. This is normal during firmware upgrade process. STS is used to indicate the heartbeat of the Microcontroller.
EasyIO FW Series – User Reference v3.0 Restore factory settings This function is done with just the by pressing the “Service” button while the controller is booting up. A restore to factory settings will do the following; 1. 2. 3. 4. Restore the IP address to the default which is 192.168.10.30 Clear the Sedona application in the Sedona VM back to default (default app is an empty app) A default Sedona apps default login is admin, .
EasyIO FW Series – User Reference v3.0 Technical Support For technical issue, please contact respective region support channel. Worldwide and Asia Pacific Support Americas Support Europe Support : support@easyio.com : support@easyio.pro : support@easyio.