GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Utility Scanner Model US1 User Manual October 9, 2019 Copyright © 2019 ESS, LLC. All rights reserved.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Table of Contents 1 2 3 4 FCC Class A Compliance and Usage Limitations................................................................ 3 IC Compliance and Usage Limitations ................................................................................ 5 FCC/IC Radiation Exposure Statement ............................................................................... 6 Introduction ............................
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 1 FCC Class A Compliance and Usage Limitations This device complies with Part 15 Subpart B and Subpart F of the FCC Rules. Operation is subject to the following two conditions: (1) the device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. FCC ID: 2AP78-US1 and contains RF Module FCC ID: Z64-WL18DBMOD.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 pertinent contact information of the user, the desired geographical area(s) of operation, and the FCC ID number and other nomenclature of the UWB device. If the imaging device is intended to be used for mobile applications, the geographical area(s) of operation may be the state(s) or county(ies) in which the equipment will be operated.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 2 IC Compliance and Usage Limitations This device complies with Canadian RSS-220, RSS-GEN and ICES-003. Operation is subject to the following two conditions: (1) the device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. IC: 2AP78-US1 and contains RF Module IC:451I-WL18DBMOD.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 3 FCC/IC Radiation Exposure Statement This equipment complies with the IC/FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and any part of your body. Cet équipement est conforme aux limites d'exposition aux rayonnements énoncées pour un environnement non contrôlé.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 4 Introduction 4.1 Overview This document provides the operating and configuration instructions for the Utility Scanner. The Scanner locates subsurface objects and utility lines such as such as pipes, conduits, and vaults, and can locate defects such as voids. The scanner can produce simple cross sections, depth slice images, or 3D images of the subsurface.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 4. The sensor unit with GPR, odometer, and power line sensors. 5. Tablet computer (may be provided separately). 5 Operation This section provides operating instructions for conducting surveys, generating reports, and recharging the batteries. Before starting survey, the needs to determine the area to be surveyed and how that area will be covered.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 2. Unscrew the securing fastener on the retainer cross bar and pivot the cross bar out of the way. Remove the scanner and the tablet from the shipping case. Remove one of the batteries from the charger in the shipping case and insert into the scanner. 3. Remove the handle from the shipping case and attach it to the scanner. Adjust the angle of the extension tube as desired. 4.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Figure 4. Upper panel shows acquisition program with status panel visible and lower panel has status panel hidden. Use the circled icon to hide/show the status panel. 5.2 Conduct a Single Line Survey A single line surveys is a quick method that is usually used to find where a small number of subsurface objects beneath the survey line. To conduct a survey, proceed as follows. Copyright © 2019 ESS, LLC.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 000023 October 9, 2019 1. Turn on the power to the sensor unit. The power switch should glow with a green light. After a few seconds the light will begin to flash rapidly – indicating that it is searching for the least congested WiFi channel channel. The light will stop blinking after the search completes (about 60 seconds). 2. Boot up the tablet computer and log in.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 e. Depth/Time range Users can opt to display the full range, half range, quarter range, or eighth range. Users may wish to display only a shallow portion of the usable range when interested in the more shallow portions of the surveyed range (depth). f. Velocity of medium The velocity of EM waves is dependent on the material type.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Figure 5. The plot configuration dock. The GPR4 Record tab also has buttons for saving the B-scan image and generating a short report . The image can be saved as a PNG, BMP, or JPG file. The report will be saved as a PDF file, and will contain the survey metadata and the B-scan image. 7. Before beginning a survey, it is important to capture information about the jobsite.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 c. Local Frame Parameters Select the distance Units (feet or meters). Enter the bearing of the first survey line in the Line 1 Azimuth field. The software will use this value to correctly orient images on maps that are exported as KMZ or HTML files. Figure 6. Jobsite information dialog. 8. Move the scanner to the start position of the line.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 000023 October 9, 2019 1. Turn on the power to the sensor unit. The power switch should glow with a green light. 2. Boot up the tablet computer and log in. Enable mouse pointer using the mouse icon on the task bar if desired. 3. Connect to the sensor unit via WiFi. On the task bar, pr press ess the WiFi network icon , then select the network connection for the Pavement Scanner.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC f. D-000002-000023 October 9, 2019 Velocity of medium The velocity of EM waves is dependent on the material type. In order to properly convert from time of flight to depth, the velocity of the medium must selected (see Depth/Time units above). Select the medium type and the corresponding dielectric constant.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Figure 7. Upper panel shows a survey grid with alternating lines, and lower panel shows the survey grid dialog. 8. Before beginning a survey, it is important to capture information about the jobsite. Press the Jobsite information button to bring up the dialog shown in Figure 6. The information entered into this dialog will be listed in any reports that will be generated by the software.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 a. Enter the Project Name, Site Location, Site Description, Operator, Survey Mode, Notes, Service Provider, and Equipment Model. The Date Recorded and Time Recorded fields will be updated automatically. b. Map Frame Parameters Select the distance Units (feet or meters). The Latitude, Longitude, and Elevation parameters will be updated automatically once the survey begins using the GPS sensor in the sensor unit.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 2. Start the data acquisition program by touching and holding the EssGpr4LoggingApp icon on the desktop. Select the Pavement Condition tab. 3. Press the button and input the desired grid layout that will be used when replotting the data. 4. Select File, Open, and then the file(s) to replay. 5. The plots will update during the course of replaying the data.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 5.8 System Care, and Cleaning The pavement density system kept clean and free of debris. The sensor unit can be cleaned with water and a mild detergent. 6 Theory 6.1 Theory of Operation The Utility Scanner uses ground penetrating radar (GPR) to characterize the surface beneath the sensing unit. The GPR sends a low-energy impulse of electromagnetic (EM) energy towards the surface.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 7 Appendix 7.1 Digitizer Settings The default settings for the digitizer are sufficient for nearly all surveys. Advanced users may choose to change these settings (see Figure A1). To view or change the digitizer settings, select (File, Settings). 1. Trace Sample Rate Select the desired number of traces per second.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC 2. 3. 4. 5. 6. 7. 8. 9. D-000002-000023 October 9, 2019 c. Panasonic Toughpad FZ-G1 Turn on the tablet, wait for it to boot up, and then log in. Press the Window icon in the lower left corner, then select Settings (the gear shaped icon). Select System, Display, and set the Resolution to 1920 x 1200. Then set the Orientation to Landscape. Finally, set Rotation lock to On. Close the Settings window.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 results and performance of the PRODUCT is assumed by you. If the PRODUCT is defective or used improperly, you, and not ESS or its dealers, distributors, agents, or employees, assume the entire cost of all necessary servicing, repair or correction.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 UN3481 For assistance call 303-800-2000 Figure A2. Shipping label for container with batteries. 7.7 Technical Support Technical support is provided by ESS between the hours of 9:00 AM and 5:00 PM MST at 303-800-2000. Copyright © 2019 ESS, LLC. All rights reserved.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 7.8 Specifications • • • • • • • • • • • • • • • • • 750 MHz bi-static radar antenna 350 MHz bi-static radar antenna Electric field sensor for detecting power lines or tracer signals Magnetic field sensor for detecting power lines or tracer signals Dimensions: 25W x 30L x 29.9H inches (63.5 x 76.2 x 75 cm) including wheels and skid plate Shipping container dimensions: 36 x 28 x 20 inches (91.4 x 71.1 x 50.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 Figure A3. Screenshot from HDFView showing the contents of an H5 file recorded by the sonic logging system. 7.10 License Agreement End User License Agreement (EULA) for EssGPR4LoggingApp and ESSentialUnderground This is a legal agreement between Earth Science Systems, LLC and you, the Customer. By installing this software, you accept all the terms and conditions of this agreement.
GPR4 Utility Scanner – User Manual Earth Science Systems, LLC D-000002-000023 October 9, 2019 5. This agreement will be governed by the laws of the United States of America. If any part of this Agreement is found void and unenforceable, it will not affect the validity of the balance of the Agreement, which shall remain valid and enforceable according to its terms. Earth Science Systems, LLC 11485 W. I-70 Frontage Rd.; Unit B Wheat Ridge, CO 80033 USA Copyright Earth Science Systems, LLC.