User User Manual Manual FM FMWireless WirelessHome HomeSecurity Security Alarm AlarmSystem System TM -- SpeedCop SpeedCopTM 20002000- Dynamic Technology Inc. www.dynamictek.
Index SpeedCopTM 2000 Description Page(s) Description Page(s) Standard Scope of Supply 2 Voice Recording 18 Option 3 Exit 19 Siren ON/OFF 20 Layout Layout -Front 4 Input(Overall) 21 Layout -Rear 6 Arming & Disarming 22 Operating flow 8 Special Function Installation Guide Bypass & Delay Time 23 24 Order of installation 9 Chime Function Power and Sensors 10 ARS Structure Main Body, PIR/Door Sensors 11 Remote Control 25 Remote Control Code 26 Input Attention & Reque
Standard Scope of Supply Division ITEM SpeedCopTM 2000 Appearance Specification Power Supply Unit : DC9V Battery, 600mA Power Consumption : Disarms(150mA), Arms(300mA) Max. Sensor No. : 7 Wireless + 2 Wire Main Body Max. Remote control No. : 7 units Max. recording No.
Option SpeedCopTM 2000 Gas Detector Detection Method : Contact Combustion Response Speed: Within 20 Sec. Detects LNG & LPG, Butane/Methane Gas Power : AV 220V, 50/60Hz Power Consumption : 2.7W Dimensions : 46D x 116H x 66W Gas Controller Power : AV 110/220V(60Hz) Power Consumption : 1.
Layout - Front SpeedCopTM 2000 The front cover is opened Main Body(Front) Front Cover Antenna LCD(Liquid Crystal Display) 1 2 3 4 5 Army 1 2 3 DisArm 4 5 6 Bypass 7 8 9 * 0 # Alarm 911 Ambulance 6 7 ARM POWER Police 9V Alkaline Battery Cover : Close / Open 16 17 18 Cut off the power If the main power is cut off, the main body can operate itself by DC 9V alkaline battery continuously.
Layout - Front SpeedCopTM 2000 1. Front Cover : Main body cover of SpeedCop TM 2000 2. Arming LED : Per each sensors Red light shows when the sensor is armed 3. Antenna : Receiving the FM signal of each sensors 4. Arming LED : Classification of Arming or Disarming 5. Power : Checking of power ON/OFF(Yellow light) 6. LCD(Liquid Crystal Display) : Showing the order or input text on the LCD 7. Arm : Arming of all the sensors. 8. Disarm : Disarming of all the sensors. 9.
Layout - Rear SpeedCopTM 2000 Main Body(Rear) X X X X X X X X X X Rear Terminal You can use wire sensors usually.==> You may use additional wire sensors. 1. External Lamp : Notice emergency to outside by light 2. External Siren : Notice emergency to outside by siren 3. Impact Detector : Install at windows for detecting intruder 4. Infrared Detector : Installing both sides of intruding route and detector sensing when intruder passes through this route 5. Fire Detector : Detecting fire and smoke 6.
Layout - Rear SpeedCopTM 2000 1. Speaker : For siren, ARS comment or key tone. 2. Telephone port : Connecting port between the main body and telephone 3. Line port : Connecting port to main body from the line of the telephone office 4. T Hanger : Use when the main body is hanging on the wall 5,6. Telephone line terminal : Connecting to Line port No.3 or telephone line terminal which comes from telephone office line 7.
Operating Flow SpeedCopTM 2000 rr uu dd ee ee rr II nnIIttnnrrtt rr uu dd r ttrr tt hh aa ra a CC w--wC -- C hh l oollw FF lF F oo w Intruders & Emergency Intr Sensor #1 ude rs Sensor #2 Automatic Dialing to the personal Cellular Phone or other designated destination (7 Memorized Telephone Numbers) Sensor #7 FM Transmission (1 Km Direct Distance) Tapping and checking by sounds from the outside Emergency Call PSTN : Local Telephone Controlling of the intruder with Siren and arms(Option) #1 PCS
Installation Guide- Order of installation SpeedCopTM 2000 1. Check the position of Main body & Sensors - Considering the position of main power & telephone line 2. Unpacking the SpeedCop 2000 3. Connecting the telephone line and the power to the Main Body - Main Power : for DC 9V(adapter) 4. Input the telephone numbers, set up sensors and remote controller. 5. Connecting each sensors to input & output terminal - ex : Gas detector, siren, wire sensor, etc.(Picture 2) 6 .
Installation Guide - Power & Sensors SpeedCopTM 2000 Telephone Line Connecting of Power & Telephone line Telephone Office Line DC 9V AC 110V, 60Hz Connecting of Sensors Siren Telephone line IN Output 1 Output Com Output 2 Input 1 Input Com Input 2 Gas Parts GND DC 12V Gas controller Gas Breaker Other wire sensors Picture 2 10 Dynamic Technology Inc.
Installation Guide - Main Body, PIR/Door Sensor SpeedCopTM 2000 Main Body (For attaching on the wall) Setting up T-tag on the wall Hanging the Main body at the three points of the T-tag PIR Sensor 45 0 Distance: about 8 meter 1. The position of PIR sensor is suitable opposition side from door or intrusion route 2. Please install PIR sensor after setting up sensors. Door Sensor Magnetic Bar RF Transmitter Within 1Cm 1. Not more than 1Cm between the two magnetic bars 11 Dynamic Technology Inc.
Input - Attention and Reset SpeedCopTM 2000 Input set up is being done when in disarming mode only If you want to cancel inputting information while you input, please enter asterisk key Use reset for deletion purpose only lerr nnttrroollle o C o e t C mooteReesseett RReem R Keypad LCD(Liquid Crystal Display) Resetting of the first remote controller 1. Press the number 2. Press the number 1 again (The second remote controller is 2 3. Press the # Key 4.
Input - Remote Controller SpeedCopTM 2000 * Input set up is being done when in disarming mode only Input Inputcode codenumber number Division Input Code Division Input Code Remote Controller 11 ~ 17 Password 51 Sensor (1)21 ~ (1)27 Recording of User’s comment 61 Telephone Number 31 ~ 37 Replaying of the user’s comment 62 Emergency Call 41 ~ 43 Exit 71 (*Siren On/Off : 81) Keypad lleerr l o l r t o n r ttee ccoont o o m e RRem Input the first Remote controller LCD(Liquid Crystal Displ
Input - Sensors SpeedCopTM 2000 Keypad oorrss s n s e n SSe LCD(Liquid Crystal Display) Input of the first sensor SpeedCop 2000 1. Press the number 2 Key * Menu Input : 2 2. Press the number 1 Key (The second sensor No. : 2 * Menu Input : 21 3. Press the 4.
Input - Telephone Number er mbber NNuum e n e o h on TTeelleepph SpeedCopTM 2000 Keypad LCD Display Input the first Telephone number 1. Press the number 2 2. Press the number 1 key - The second telephone number : 2 3. Press the # 4. 5. key Key Please input the first telephone number(ex : 323-2680) Press the # Key SpeedCop 2000 * Menu Input : 3 * Menu Input : 31 Tel.
Input - Emergency Call cy rrggeenncyr e m e EEm mbbeer u ccaallllnnum SpeedCopTM 2000 Keypad LCD(Liquid Crystal Display) Input the first emergency call number SpeedCop 2000 1. Press the number 4 Key * Menu Input : 4 2. Press the number 1 Key * Menu Input : 41 3. Press the # 4. 5.
Input - Password SpeedCopTM 2000 Keypad oorrdd w s w s s PPaas Input of Password LCD(Liquid Crystal Display) SpeedCop 2000 1. Press the number 5 Key * Menu Input : 5 2. Press the number 1 Key * Menu Input : 51 3. Press the number # Key * Password : 4. Please input 4 digit password * Password : 5. Press the # Key 1234 ent Comm ARS Input Completed In this case, needing password - Control the main body with remote control from outside by telephone.
Input - Voice Recording ooiiccee V V g n g i ccoorrddin e e R R SpeedCopTM 2000 Keypad LCD(Liquid Crystal Display) Voice Recording SpeedCop 2000 1. Press the number 6 Key * Menu Input : 6 2. Press the number 1 Key * Menu Input : 61 3. Press the # Key * Recording : 12 4. The main body will start recording warning message for 12 seconds ay RReeppllay Replay of recorded voice SpeedCop 2000 1. Press the number 6 Key * Menu Input : 6 2. Press the number * Menu Input : 62 3.
Input – Delay Time SpeedCopTM 2000 Keypad LCD(Liquid Crystal Display) mee TTiim y a y l a e D Del Input Exit time SpeedCop 2000 1. Press the number 7 Key * Menu Input : 7 2. Press the number 1 Key * Menu Input : 71 3. Press * Delay Time : 4. Input the interval time you wanted (ex : 15 seconds) 5. Press the # Key # Key * Delay Time : 15 ent Comm ARS Input Completed * Exit time that you go out from home to outside.
Input - Siren On/Off SpeedCopTM 2000 Keypad LCD Display SSiirreenn Siren ON/OFF SpeedCop 2000 1. Press the number 8 Key * Menu Input : 8 2. Press the number 1 Key * Menu Input : 81 3. Press the * Siren : ON * Siren : OFF 4. 5. # Key Please press any number key( 1 ~ 9 ) The main body is changed from on(off) to off(on) automatically. Press the # Key ent Comm ARS Input completed 20 Dynamic Technology Inc.
Input - overall SpeedCopTM 2000 Key Function : (* : Cancel, # : Enter) No. Keypad ARS Comment 1 1 + 1 + # Remote controller No.1 : ON Input completed 2 11 + 21 + # Remote controller No.2 : ON Input completed 3 11 + 31 + # Remote controller No.3 : ON Input completed 4 1 + 4 + # Remote controller No.4 : ON Input completed 5 1 + 5 + # Remote controller No.5 : ON Input completed 6 1 + 6 + # Remote controller No.
Arming & Disarming SpeedCopTM 2000 Arming Arming Disarming Disarming All sensors armed Converting from Arming to disarming mode ent Comm ARS Arming Completed ent Comm ARS Disarming Completed *Time Out : 15 Only power LED is On in standby mode Green LED is flicker 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Arm Power Aem Power 22 Dynamic Technology Inc.
Arming & Disarming – manual use SpeedCopTM 2000 Delay DelayTime Time Arming Arming&&Disarming Disarming After arming, delay time in order to go out from Operating appointed sensors by user only Arming or Disarming inside to outside(0~99 seconds).
Special Function - Bypass & Alarm SpeedCopTM 2000 Bypass Bypass Chime Chime Operating appointed sensors by user only If doors or windows are open, the main body informs the fact Bypass In case third door sensor is opened ent Comm ARS Enter password * Password : The Third LED flickers 1234 Chime ent Comm ARS ent Comm ARS Arming Completed A door is opened * Time Out : 15 * Door Sensor #3 Sensor 1 and 3,5,7 are armed Arm led is flicker Close the door or the window 1 2 3 4 5 6 7 Arm Po
ARS Structure - Remote Control Arming of SpeedCop Sensing intruder. Sensing gas leakage SpeedCopTM 2000 Connecting from outside Arming mode : Control after ringing 3 times Arming, Disarming & Bypass mode : Control after ringing 8~9 times Sensing fire.
ARS Structure - Remote Control Code SpeedCopTM 2000 10 20 Arming Disarming - Keeping main body on disarming mode - Keeping main body on arming mode by remote control or push arming button. by remote control or push Disarming button. Example : when the main body senses the intruder is not a burglar. 50 * Both side END - Hearing footsteps, sound or whisper etc. - This command stops the main body from - Shout to intruder out - end of emergency by remote control calling the next telephone number.
Guide of emergency meeting SpeedCopTM 2000 User must control by phone to meet emergency after receiving telephone Sensing Controlling Tapping (50) Intruder Listen to the ARS comment that a intruder is detected and then check whether it is family or intruder Ring a siren (30) Threaten the intruder by siren & call the police Sensing Turn off the siren (40) Tapping (50) Listen to the ARS comment that a fire is detected Fire Ring a siren (30) Sensing Shut off the Gas (60) Checking gas siren (50)
Power & Tel. Line Cut Off SpeedCopTM 2000 Cutting off of main power Coming from DC 9V battery at the main body Appearance - Power LED changes from yellow to green - Light of LCD is off * Most function is the same as before. * Back up battery : DC 9V Alkaline battery only(Duration : about. 6 hours) Cutting off of telephone line 1. Arming(Includes Stay function) ent Comm ARS Please connect telephone line 2.
Sensor Feature - PIR Sensor/Remote controller SpeedCopTM 2000 PIR PIRSensor Sensor • FM (Frequency Modulation) Type - Increasing of communication distance •PIR sensing function •Sensing distance : Approx..
Sensor Feature - RF transmitter & Door sensor SpeedCopTM 2000 RF RFTransmitter Transmitter Radio Frequency Transmitter • FM (Frequency Modulation)Type - Increasing the communication distance • For door sensor, Gas sensor, Fire sensor • Communication distance : about. 1Km direct distance • Notice of low voltage • Life cycle of battery : Min.
WARNING Please Read Carefully SpeedCopTM 2000 Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
WARNING Please Read Carefully SpeedCopTM 2000 . System Users A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm.