Dust Networks D1100/ M1010EVM Evaluation Kit Quick Start Guide
Trademarks Dust Networks, the Dust Networks logo, and SmartMesh are trademarks of Dust Networks, Inc. All third party brand and product names are the trademarks of their respective owners and are used solely for informational purposes. Copyright This documentation is protected by United States and international copyright and other intellectual and industrial property laws. It is solely owned byDust Networks, Inc. and its licensors and is distributed under a restrictive license.
Contents About This Guide Related Documents ..........................................................................iii Conventions Used ..............................................................................iii 1 M1010 Evaluation Module M1010 Evaluation Module ........................................................... 1 Connector P1 .......................................................................................... 2 Connector P2 ..........................................................
TABLE OF CONTENTS ii D1100 EVALUATION KIT QUICK START GUIDE
About This Guide This guide provides information required to successfully demonstrate the capabilities of the D1100 Evaulation Kit. It provides various pinout and connector information for attaching sensors to a M1010 Evaluation Module and instructions for setting up a network.
CHAPTER 1 - ABOUT THIS GUIDE Conventions Used Body.
M1010 Evaluation Module 1 This chapter provides specifications for the M1010 Evaluation Module (M1010-EVM) provided in the D1100 Evaluation Kit. The M1010-EVM can be used as a reference design for integrating an M1010 Mote into a self-contained device. M1010 Evaluation Module The M1010-EVM consists of an M1010-A Mote, packaged with an antenna, battery holder, status LEDs, I/O connectors, and a recessed reset switch.
CHAPTER 1 - M1010 EVALUATION MODULE Connector P1 Connector P1 Connector P1 is a 4-position terminal block connector that accepts 12-22 AWG wire. It assumes 0 to 5 V inputs, and contains internal filter circuitry for 60 Hz noise. Table 1-1. Pin Number P1 Connector Pinouts Pin Name I/O Description 1 A1 I 2 GND I Ground 3 A2 I Analog input 2 (0 - 50) 4 GND I Ground Analog input 1 (0 - 50) cWarning: Reverse biasing these inputs may result in damage to the device.
Connector P2 CHAPTER 1 - M1010 EVALUATION MODULE Connector P2 Connector P2 is an HD-15 female connector, as shown in Figure 1-2. It assumes 0 to 1.5 V analog inputs, and is unfiltered. All digital I/O are LVTTL (3 V) signaling. Figure 1-2. HD-15 Female Connector Table 1-2.
CHAPTER 1 - M1010 EVALUATION MODULE Serial Interface Serial Interface Connector P2 provides a flow-controlled serial interface with timing information (using TX, RX, CTS, and SOF), as described in the M1010 Mote Integration Guide, Appendix C. Serial port settings are 9600 bps, 8 data bits, no parity, 1 stop bit. Power Supply The M1010-EVM board is powered by a pair of L91 1.5 V AA lithium batteries (or equivalent), and comes with a standard double AA battery holder.
Recommended Operating Conditions CHAPTER 1 - M1010 EVALUATION MODULE Recommended Operating Conditions Table 1-4. Operating Conditions Max Units Analog input impedance Parameter Min 75 kΩ Analog input capacitance 40 pF Condition Wireless Specifications Table 1-5. Wireless Specifications Parameter Frequency Band RF output power Max Units 902 - 928 MHz 4 dBm Transmit data rate 76.
CHAPTER 1 - M1010 EVALUATION MODULE Regulatory Information Regulatory Information The FCC ID: SJC-M1010EVM. This device complies with Part 15 o the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. bNetworks™ Caution: Unauthorized modification or changes not expressly approved by Dust Inc.
SmartMesh Manager 2 This chapter describes the D1100 SmartMesh Manager provided in the D1100 Evaluation kit. The D1100 is used to configure and control a network of M1010 motes, and provides data and configuration information via an XML/RPC interface. Description The D1100 SmartMesh Manager consists of a single board computer and an M1010 mote. The M1010 mote acts as a radio gateway between the single board computer and the Dust Network.
CHAPTER 2 - SMARTMESH MANAGER Connections Connections The D1100 SmartMesh Manager has the following ports available: • 10/100 Ethernet port—Used for connection to a LAN or direct connection to a computer using the cross-over cable provided in the D1100 Evaluation Kit. Refer to the SmartMesh Manager Administration Guide for information on configuring the IP address of the SmartMesh Manager. • Serial 1 port (RS232)—Reserved for future connection. 115 kbps maximum.
Regulatory Information CHAPTER 2 - SMARTMESH MANAGER Regulatory Information The FCC ID: SJC-D1100. This device complies with Part 15 o the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. bNetworks™ Caution: Unauthorized modification or changes not expressly approved by Dust Inc.
CHAPTER 2 - SMARTMESH MANAGER 10 Regulatory Information D1100 EVALUATION KIT QUICK START GUIDE
Setting Up a Network 3 This chapter describes how to set up a D1100 Evaluation Kit in a simple sensor network. For a more detailed explanation, see the Getting Started Guide that came with your evaluation kit. Setting Up the SmartMesh Manager A B C D E F G Install the SmartMesh Console software. Connect Manager to the PC using the cross-over cable. Connect power to the Manager. If necessary, adjust the IP address of the PC to allow connection with the manager. Start Console. Connect to Manager.
CHAPTER 3 - SETTING UP A NETWORK 12 Setting Up the Network D1100 EVALUATION KIT QUICK START GUIDE